Abbreviation
OP

RadSeeker Operational Test

Last Updated: 07/13/2025 1:37 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Smiths Detection RadSeeker CS
Device
Published
06/04/2025 3:30 PM
247 - 257 - Prepare instrument; Remark:
Procedure Step
Published
04/11/2025 9:08 PM
257 - Prepare instrument
Instruction
Published
04/11/2025 9:07 PM
786 - 219 - Verify there are no sources of radiation near instrument; Remark:7
Procedure Step
Published
04/20/2025 6:37 PM
219 - Verify there are no sources of radiation near instrument
Instruction
Published
04/12/2025 4:20 PM
7 - No Radiation symbol
Remark
Published
07/12/2021 1:34 PM
3512 - 2295 - Verify sufficient battery charge; Remark:2297
Procedure Step
Published
07/28/2021 9:32 PM
2295 - Verify sufficient battery charge
Instruction
Published
04/06/2021 4:43 PM
2297 - IO RadSeeker 3 bar Battery
Remark
Published
10/19/2024 10:28 PM
2460 - 220 - Power on instrument; Remark:2303
Procedure Step
Published
11/04/2020 5:34 PM
2360 - Caution : Temperature must be above -15°C for instrument to start. Do not operate the ...
Annotation
Published
11/04/2020 5:27 PM
220 - Power on instrument
Instruction
Published
04/06/2025 7:00 PM
2303 - Press and hold ENTER button until display powers on (3 to 5 ...
Remark
Published
07/23/2021 8:41 PM
2298 - IO RadSeeker Button Pad Select Button Yellow Box
Remark
Published
10/21/2024 7:26 PM
2462 - 612 - Wait for instrument to complete start-up sequence; Remark:2306
Procedure Step
Published
04/13/2025 6:49 PM
612 - Wait for instrument to complete start-up sequence
Instruction
Published
04/13/2025 6:38 PM
2306 - The instrument will automatically enter Detect mode after sy...
Remark
Published
07/23/2021 8:45 PM
252 - 232 - Check instrument gamma response; Remark:
Procedure Step
Published
07/29/2021 11:10 AM
232 - Check instrument gamma response
Instruction
Published
07/23/2021 9:58 AM
3513 - 2352 - Verify Audible Dose Rate Indicator (ADI) is on; Remark:3502
Procedure Step
Published
07/28/2021 9:34 PM
2352 - Verify Audible Dose Rate Indicator (ADI) is on
Instruction
Published
07/29/2021 12:52 PM
3502 - Use ADI button to activate an auditory equivalent to the visual historical gr...
Remark
Published
07/28/2021 9:18 PM
2324 - IO RadSeeker ADI Bar
Remark
Published
10/21/2024 7:33 PM
3514 - 235 - Place instrument next to radioactive gamma source; Remark:3507
Procedure Step
Published
06/06/2022 5:25 PM
235 - Place instrument next to radioactive gamma source
Instruction
Published
07/09/2021 1:39 PM
3507 - IO RadSeeker Closer to Trefoil
Remark
Published
10/21/2024 8:54 PM
3515 - 3509 - Verify DETECT mode responds correctly; Remark:3510
Procedure Step
Published
07/28/2021 9:36 PM
3509 - Verify DETECT mode responds correctly
Instruction
Published
07/28/2021 9:37 PM
3510 - The instrument should respond as follows:
Remark
Published
07/28/2021 9:28 PM
2310 - Gamma Dose Rate (µSv/hr) values will increase. Gamma coun...
Remark
Published
11/04/2020 7:38 AM
3516 - 241 - Move instrument away from radioactive gamma source; Remark:3508
Procedure Step
Published
06/06/2022 5:27 PM
241 - Move instrument away from radioactive gamma source
Instruction
Published
06/25/2021 12:22 PM
3508 - IO RadSeeker Away from Trefoil
Remark
Published
10/21/2024 8:54 PM
3517 - 3511 - Check Instrument Neutron Response; Remark:
Procedure Step
Published
07/28/2021 9:39 PM
3511 - Check Instrument Neutron Response
Instruction
Published
07/28/2021 9:29 PM
3519 - 3095 - Place instrument next to radioactive neutron source; Remark:3507
Procedure Step
Published
06/06/2022 6:30 PM
3095 - Place instrument next to radioactive neutron source
Instruction
Published
07/16/2021 10:49 AM
3518 - 3501 - Verify DETECT mode responds correctly; Remark:3500
Procedure Step
Published
07/28/2021 9:40 PM
3096 - Note : Most radioactive neutron sources also have a gamma component, which will likely ...
Annotation
Published
07/23/2021 9:57 AM
3501 - Verify DETECT mode responds correctly
Instruction
Published
07/28/2021 9:12 PM
3500 - The instrument should respond as follows: Vibrate and alarm...
Remark
Published
07/28/2021 9:42 PM
3499 - N-cps values will increase and have a red color. Moving gr...
Remark
Published
07/28/2021 9:10 PM
3520 - 3098 - Move instrument away from radioactive neutron source; Remark:3508
Procedure Step
Published
06/06/2022 6:33 PM
3098 - Move instrument away from radioactive neutron source
Instruction
Published
07/16/2021 10:54 AM
2251 - 2217 - Perform Identification Measurement; Remark:
Procedure Step
Published
07/28/2021 9:55 PM
2217 - Perform Identification Measurement
Instruction
Published
04/06/2021 5:13 PM
3521 - 859 - Start identification measurement; Remark:3498
Procedure Step
Published
07/28/2021 9:46 PM
859 - Start identification measurement
Instruction
Published
10/26/2020 7:00 PM
3498 - Press ENTER under Start ID
Remark
Published
07/28/2021 9:07 PM
3486 - IO RadSeeker StartID Small Menu
Remark
Published
10/21/2024 8:54 PM
2491 - 2220 - Wait for measurement to complete; Remark:2321
Procedure Step
Published
04/20/2025 12:55 PM
2220 - Wait for measurement to complete
Instruction
Published
10/22/2020 11:15 AM
2321 - IO RadSeeker Collecting Spectrum Wait
Remark
Published
10/21/2024 8:36 PM
2492 - 2357 - Acknowledge alarms; Remark:2326
Procedure Step
Published
11/04/2020 5:49 PM
2357 - Acknowledge alarms
Instruction
Published
07/23/2021 9:29 PM
2326 - Press ENTER to acknowledge innocent or threat alarms.
Remark
Published
07/23/2021 9:35 PM
2320 - IO RadSeeker Alarm Acknowledge Threat
Remark
Published
10/21/2024 8:40 PM
3522 - 1442 - Verify identification results are correct; Remark:3497
Procedure Step
Published
07/28/2021 9:47 PM
1442 - Verify identification results are correct
Instruction
Published
09/02/2020 3:03 PM
3497 - Identification results should match the isotopes associated with the radioact...
Remark
Published
07/28/2021 9:04 PM
2319 - IO RadSeeker Identify Isotope Co60
Remark
Published
10/21/2024 8:42 PM
253 - 242 - Document and report any unresolved problems; Remark:
Procedure Step
Published
06/22/2021 10:23 AM
242 - Document and report any unresolved problems
Instruction
Published
04/21/2025 11:45 AM
Operator Procedure
Document Type
Published
03/02/2020 3:31 PM
5 minutes
Duration
Published
04/01/2020 11:35 AM
Annually
Frequency
Published
04/01/2020 11:37 AM
Before each use
Frequency
Published
08/31/2020 5:00 PM
Monthly
Frequency
Published
04/01/2020 11:36 AM
Caution
Annotation Type
Published
03/02/2020 3:24 PM
Note
Annotation Type
Published
03/02/2020 3:25 PM
Technician 1
Skill Level
Published
05/14/2020 2:56 PM
None
Tools
Published
05/06/2020 9:50 PM
No Radiation Symbol
រូប​ភាព
Published
08/13/2024 2:56 PM
radseeker_di_battbar_000477.jpg
រូប​ភាព
Published
10/18/2023 4:32 PM
radseeker_di_selectmiddle_00473.jpg
រូប​ភាព
Published
10/20/2023 9:35 AM
radseeker_ui_modedetect_217cps_00467.jpg
រូប​ភាព
Published
10/20/2023 10:15 AM
radseeker_ui_adiselect_00471.jpg
រូប​ភាព
Published
10/20/2023 9:42 AM
radseeker_di_MoveToward_rad_00668.jpg
រូប​ភាព
Published
10/20/2023 9:33 AM
radseeker_ui_increasgr_11164cps_00463.jpg
រូប​ភាព
Published
10/20/2023 10:07 AM
radseeker_di_MoveAway_rad_00669.jpg
រូប​ភាព
Published
10/20/2023 9:32 AM
radseeker_ui_neutronalarmack_nobutton_252cps_00654.jpg
រូប​ភាព
Published
10/20/2023 10:18 AM
radseeker_ui_alarm_neutron_1783cps_00656.jpg
រូប​ភាព
Published
10/20/2023 9:43 AM
radseeker_ui_menustartid_button_00651.jpg
រូប​ភាព
Published
10/20/2023 10:11 AM
radseeker_ui_collectspec_00468.jpg
រូប​ភាព
Published
10/20/2023 9:46 AM
radseeker_ui_threatack_1025cps_00457.jpg
រូប​ភាព
Published
10/20/2023 10:22 AM
radseeker_ui_idco60_902cps_00465.jpg
រូប​ភាព
Published
10/20/2023 10:06 AM