9044 - 9040 - +15 VDC at LD-260 Output? - Decision, Notes: 9041

9040 - +15 VDC at LD-260 Output?

+15 VDC at LD-260 Output?
Yes
Go to
9024 - 9019 - Inspect Wiring - Process, Notes: 9023
No
Go to
9009 - 9006 - Replace LD-260 - Formal Procedure, Notes: 9007
Note
9041 - Using a digital multimeter in DC mode,verify 15 VDC at TB1 pins 1, 2, and 3.
9042 - measure the voltage at LD-260 output, Molex J4, between pins 4 and 5.
9043 - Is there approximately +15 VDC present?