9040 - +15 VDC at LD-260 Output? +15 VDC at LD-260 Output? Yes Go to 9024 - 9019 - Inspect Wiring - Process, Notes: 9023 No Go to 9009 - 9006 - Replace LD-260 - Formal Procedure, Notes: 9007 Note 9041 - Using a digital multimeter in DC mode,verify 15 VDC at TB1 pins 1, 2, and 3. 9042 - measure the voltage at LD-260 output, Molex J4, between pins 4 and 5. 9043 - Is there approximately +15 VDC present?