Last Updated: 06/18/2025 1:43 AM
The following table lists all the components that make up the document.
Install the BEA IXIO-DT1 occupancy sensor on the pedestrian radiation portal monitor (RPM). The existing Visonic SPY-2 infrared curtain sensor is abandoned in place.
Verify occupancy sensor functionality
Prior to arrival, notify operators concerning expected work, duration, and anticipated alarms and fault indications.
Updated LD-260 images to re-usable standardized content. Updated instructions to standardized re-usable content.
7264 - 1401 - Thiết lập các Điều kiện Ban đầu; Remark:
1401 - Thiết lập các Điều kiện Ban đầu
Thiết lập các Điều kiện Ban đầu
7622 - 7592 - Thông báo cho cán bộ vận hành sau khi đến; Remark:11335
7592 - Thông báo cho cán bộ vận hành sau khi đến
Thông báo cho cán bộ vận hành sau khi đến
11335 - Upon arrival, brief system operators on expected work, duration, anticipated ...
Upon arrival, brief system operators on expected work, duration, anticipated alarms, and fault indications before starting work.
7452 - 7231 - Close lane; Remark:7415
7231 - Close lane
Close lane
7415 - Re-route pedestrian traffic.
Re-route pedestrian traffic.
7269 - 7232 - Mở cửa hộp tủ máy RPM; Remark:7234
7232 - Mở cửa hộp tủ máy RPM
Mở cửa hộp tủ máy RPM
7234 - Mở tất cả các cửa cần thiết để tiếp cận các bộ phận.
Mở tất cả các cửa cần thiết để tiếp cận các bộ phận.
7755 - 7679 - Ngắt kết nối đầu nối Ethernet ra khỏi phía trên bộ điều khiển SC-770 của máy RPM; Remark:11336
7680- : Nhớ nhấn nút nhả ở phía sau của cáp Ethernet trước khi gỡ đầu dây.
Nhớ nhấn nút nhả ở phía sau của cáp Ethernet trước khi gỡ đầu dây.
7679 - Ngắt kết nối Ethernet
Ngắt kết nối Ethernet
11336 - Locate Ethernet connector on top of SC-770 controller. Press release button o...
Locate Ethernet connector on top of SC-770 controller. Press release button on back of connector. Pull connector.

7270 - 7235 - Tắt nguồn máy RPM; Remark:7236
7235 - Tắt nguồn máy RPM
Tắt nguồn máy RPM
7236 - Xoay công tắc LD-260 về vị trí TẮT. Đèn LED PWR ON sẽ bật.
Xoay công tắc LD-260 về vị trí TẮT. Đèn LED PWR ON sẽ bật.

7454 - 7290 - Tắt công tắc chống can thiệp thiết bị; Remark:7416
7290 - Tắt công tắc chống can thiệp thiết bị
Tắt công tắc chống can thiệp thiết bị
7416 - Sử dụng nam châm để vô hiệu hóa công tắc chống can thiệp thiết bị đối với tất cả...
Sử dụng nam châm để vô hiệu hóa công tắc chống can thiệp thiết bị đối với tất cả các cửa đang mở. Sử dụng băng dính để vô hiệu hóa các công tắc cơ học loại cũ.


8561 - 7291 - Tắt cả hai cảm biến hồng ngoại hiện diện; Remark:8514
5291- : Tốt nhất là nên kiểm tra để đảm bảo tất cả dây cáp và đầu nối đã được dán nhãn t...
Tốt nhất là nên kiểm tra để đảm bảo tất cả dây cáp và đầu nối đã được dán nhãn trước khi ngắt kết nối.
7291 - Tắt cả hai cảm biến hồng ngoại hiện diện
Tắt cả hai cảm biến hồng ngoại hiện diện
8514 - Kiểm tra xem các cảm biến gắn ở cột chính có đúng là bộ thu hay không.
Kiểm tra xem các cảm biến gắn ở cột chính có đúng là bộ thu hay không.


9205 - Để ngắt kết nối cáp cảm biến, vặn vòng đai cáp ngược chiều kim đồng hồ và kéo ra...
Để ngắt kết nối cáp cảm biến, vặn vòng đai cáp ngược chiều kim đồng hồ và kéo ra khỏi cảm biến.


7479 - 7417 - Prepare New Occupancy Sensor; Remark:
7417 - Prepare New Occupancy Sensor
Prepare New Occupancy Sensor
7456 - 7418 - Remove cover from new occupancy sensor; Remark:7419
7418 - Remove cover from new occupancy sensor
Remove cover from new occupancy sensor
7419 - Use a slotted screwdriver to pry the cover off from the side.
Use a slotted screwdriver to pry the cover off from the side.

7457 - 7420 - Verify narrow field radar antenna is installed; Remark:7421
7420 - Verify narrow field radar antenna is installed
Verify narrow field radar antenna is installed
7421 - The IXIO-DT1 should come with the narrow field antenna installed.
The IXIO-DT1 should come with the narrow field antenna installed.

8901 - If needed, the antenna can be changed. Remove cover. Install narrow field ant...
If needed, the antenna can be changed. Remove cover. Install narrow field antenna stored in slot behind antenna mount. Replace cover.


8889 - 8888 - Prepare Mounting Holes; Remark:
8888 - Prepare Mounting Holes
Prepare Mounting Holes
8884 - 8883 - Mark mounting hole height; Remark:8882
8883 - Mark mounting hole height
Mark mounting hole height
8882 - Use erasable marker or pencil to draw a level horizontal line. Mounting hole ...
Use erasable marker or pencil to draw a level horizontal line. Mounting hole height is 35 cm from top of cabinet door.

8886 - 8879 - Mark centerline of pedestrian monitor door; Remark:8878
8879 - Mark centerline of pedestrian monitor door
Mark centerline of pedestrian monitor door
8878 - Use erasable marker or pencil to draw a vertical line.
Use erasable marker or pencil to draw a vertical line.

8885 - 8881 - Attach mounting template; Remark:8880
8881 - Attach mounting template
Attach mounting template
8880 - Template provided with the IXIO-DT1 has a self-adhesive backing. Template may...
Template provided with the IXIO-DT1 has a self-adhesive backing. Template may differ from picture shown. Match template lines with vertical and horizontal marks.

8887 - 8877 - Mark location of 3.2-mm (1/8-inch) mounting holes; Remark:8876
8904 - Caution : Ensure placement of mounting holes will not interfere with internal wiring in...
Ensure placement of mounting holes will not interfere with internal wiring in the cabinet.
8877 - Mark location of 3.2-mm (1/8-inch) mounting holes
Mark location of 3.2-mm (1/8-inch) mounting holes
8876 - If available, use a center punch and hammer to create a dimple at each mounti...
If available, use a center punch and hammer to create a dimple at each mounting hole location.

8905 - 8903 - Mark location of 8-mm (5/16-inch) hole for wire passage; Remark:8902
8903 - Mark location of 8-mm (5/16-inch) hole for wire passage
Mark location of 8-mm (5/16-inch) hole for wire passage
8902 - If available, use a center punch and hammer to create a dimple at center of w...
If available, use a center punch and hammer to create a dimple at center of wire passage hole.

8946 - 8945 - Drill Installation Holes; Remark:
8945 - Drill Installation Holes
Drill Installation Holes
8939 - 8938 - Hold or block the door in an open position; Remark:
8938 - Hold or block the door in an open position
Hold or block the door in an open position
8940 - 8935 - Drill two (2) mounting holes; Remark:8934
8936 - Warning : Wear protective gloves and eyewear when drilling into cabinet door.
Wear protective gloves and eyewear when drilling into cabinet door.
8937 - Caution : Do not damage interior of RPM when drilling holes.
Do not damage interior of RPM when drilling holes.
8935 - Drill two (2) mounting holes
Drill two (2) mounting holes
8934 - Use a 3.2-mm (1/8-inch) drill bit.
Use a 3.2-mm (1/8-inch) drill bit.
8941 - 8933 - Drill wire passage hole; Remark:8932
8933 - Drill wire passage hole
Drill wire passage hole
8932 - Use an 8-mm (5/16-inch) drill bit.
Use an 8-mm (5/16-inch) drill bit.
8942 - 8931 - Clean newly drilled holes; Remark:8930
8931 - Clean newly drilled holes
Clean newly drilled holes
8930 - Use the deburring tool
Use the deburring tool
8943 - 8929 - Partially insert two (2) screws into mounting holes; Remark:8928
8929 - Partially insert two (2) screws into mounting holes
Partially insert two (2) screws into mounting holes
8928 - Mounting screws are included in the IXIO-DT-1 kit. Do not fully tighten screw...
Mounting screws are included in the IXIO-DT-1 kit. Do not fully tighten screws. Enough room should be available to slide the sensor in place.
8944 - 8926 - Insert rubber grommet in wire passage hole; Remark:8925
8927 - Note : Protecting wires with a rubber grommet is critical to preventing damage to wi...
Protecting wires with a rubber grommet is critical to preventing damage to wiring and possible equipment malfunctions.
8926 - Insert rubber grommet in wire passage hole
Insert rubber grommet in wire passage hole
8925 - rubber grommet

8924 - 8923 - Install IXIO-DT1 Sensor; Remark:
8923 - Install IXIO-DT1 Sensor
Install IXIO-DT1 Sensor
8918 - 8917 - Feed wiring connector through grommet; Remark:8915
8917 - Feed wiring connector through grommet
Feed wiring connector through grommet
8915 - The wiring assembly is included in the IXIO-DT1 kit. Feed loose end of wiring...
The wiring assembly is included in the IXIO-DT1 kit. Feed loose end of wiring assembly through hole.

8916 - Leave approximately 15 cm (6 in) of wire remaining outside of cabinet.
Leave approximately 15 cm (6 in) of wire remaining outside of cabinet.

8919 - 8914 - Mount new sensor; Remark:8912
8914 - Mount new sensor
Mount new sensor
8912 - First, slide left side onto mounting screw.
First, slide left side onto mounting screw.

8913 - Then, place right side over mounting screw and push down.
Then, place right side over mounting screw and push down.

8920 - 8911 - Tighten two (2) mounting screws; Remark:8910
8911 - Tighten two (2) mounting screws
Tighten two (2) mounting screws
8910 - Use medium Phillips (PH2) screwdriver. Take care not to overtighten.
Use medium Phillips (PH2) screwdriver. Take care not to overtighten.

8921 - 8909 - Route wiring through clamp and connect; Remark:8908
8909 - Route wiring through clamp and connect
Route wiring through clamp and connect
8922 - 8907 - Adjust angle of the radar antenna; Remark:8906
8907 - Adjust angle of the radar antenna
Adjust angle of the radar antenna
8906 - The angle is adjusted by manually rotating the antenna up or down. The defaul...
The angle is adjusted by manually rotating the antenna up or down. The default angle is approximately 15 degrees.


8970 - 8969 - Connect Wiring to RPM; Remark:
8969 - Connect Wiring to RPM
Connect Wiring to RPM
8963 - 8962 - Disconnect existing SPY-2 wiring; Remark:8961
7351 - Note : It is good practice to verify all cables and connectors are labeled prior to ...
It is good practice to verify all cables and connectors are labeled prior to disconnection.
8962 - Disconnect existing SPY-2 wiring
Disconnect existing SPY-2 wiring
8961 - Do not remove existing occupancy sensor from door panel. Disconnect SPY-2 wir...
Do not remove existing occupancy sensor from door panel. Disconnect SPY-2 wiring from terminal block 2 (TB2). Existing wiring is normally connected at pin 16, pin 15, and pin 6.

8964 - 8960 - Route new cable to TB2; Remark:8959
8960 - Route new cable to TB2
Route new cable to TB2
8959 - New IXIO-DT1 cable should be routed along existing SPY-2 cable. Cable ties ma...
New IXIO-DT1 cable should be routed along existing SPY-2 cable. Cable ties may be used to secure new wiring to existing wiring.

8965 - 8958 - Connect red wire to TB2, Pin 16; Remark:8956
7263 - Caution : Correct placement of connectors and wiring is critical to proper operation.
Correct placement of connectors and wiring is critical to proper operation.
8958 - Connect red wire to TB2, Pin 16
Connect red wire to TB2, Pin 16
8956 - Red is power (+12 VDC) wire.
Red is power (+12 VDC) wire.

8957 - For models with older terminal blocks, it may be necessary to use a fork conn...
For models with older terminal blocks, it may be necessary to use a fork connector.


8966 - 8955 - Connect both black and white wires to TB2, Pin 15; Remark:8954
8955 - Connect both black and white wires to TB2, Pin 15
Connect both black and white wires to TB2, Pin 15
8954 - Black is the ground wire. White is the common wire
Black is the ground wire. White is the common wire

8967 - 8953 - Connect green wire to TB2, Pin 6; Remark:8952
8953 - Connect green wire to TB2, Pin 6
Connect green wire to TB2, Pin 6
8952 - Green is the occupancy signal to the SCA-775 module.
Green is the occupancy signal to the SCA-775 module.

8968 - 8951 - Apply sealant if needed; Remark:8950
8951 - Apply sealant if needed
Apply sealant if needed
8950 - Access wire penetration hole from back of the RPM door.
Access wire penetration hole from back of the RPM door.

7279 - 7249 - Đưa thiết bị trở lại điều kiện hoạt động bình thường; Remark:
7249 - Đưa thiết bị trở lại điều kiện hoạt động bình thường
Đưa thiết bị trở lại điều kiện hoạt động bình thường
8949 - 8948 - Hold door open; Remark:8947
8948 - Hold door open
Hold door open
8947 - Do not move door. Door must remain stationary to prevent occupancy.
Do not move door. Door must remain stationary to prevent occupancy.
7280 - 7250 - Bật nguồn máy RPM; Remark:7251
7250 - Bật nguồn máy RPM
Bật nguồn máy RPM
7251 - Xoay công tắc LD-260 về vị trí BẬT. Đèn LED PWR ON sẽ bật sáng.
Xoay công tắc LD-260 về vị trí BẬT. Đèn LED PWR ON sẽ bật sáng.

7281 - 7252 - Kiểm tra để xác định SC-770 đã có điện; Remark:7253
7252 - Kiểm tra để xác định SC-770 đã có điện
Kiểm tra để xác định SC-770 đã có điện
7253 - Bộ điều khiển SC-770 sẽ được bật nguồn, thực hiện bước Tự kiểm tra khi bật nguồn...
Bộ điều khiển SC-770 sẽ được bật nguồn, thực hiện bước Tự kiểm tra khi bật nguồn (POST) và thu thập dữ liệu đo phông.
7470 - 7442 - Generate occupancy; Remark:7443
7442 - Generate occupancy
Generate occupancy
7443 - Create motion in front of occupancy sensor. While holding the door open and s...
Create motion in front of occupancy sensor. While holding the door open and still, wave a hand or walk in front of the sensor.
7471 - 7444 - Verify occupancy sensor functionality; Remark:7445
7444 - Verify occupancy sensor functionality
Verify occupancy sensor functionality
7445 - IXIO-DT1 green sensor light will illuminate.
IXIO-DT1 green sensor light will illuminate.

8973 - Left latch on the LCD screen will indicate a “closed” circuit.
Left latch on the LCD screen will indicate a “closed” circuit.

8974 - SC-770 status will read “OCCUPIED”.
SC-770 status will read “OCCUPIED”.

7472 - 7446 - Install sensor cover; Remark:7447
7446 - Install sensor cover
Install sensor cover
7447 - The cover should snap into place.
The cover should snap into place.

7473 - 7448 - If needed, apply sealant; Remark:7449
7448 - If needed, apply sealant
If needed, apply sealant
7449 - If used outdoors, sealant should be applied to top and sides of cover. Do not...
If used outdoors, sealant should be applied to top and sides of cover. Do not apply sealant along bottom of cover. Remove excess silicone with mineral spirits and rags.

8587 - 7305 - Enable both infrared occupancy sensors; Remark:8559
5553 - Caution : Correct placement of connectors and wiring is critical to proper operation.
Correct placement of connectors and wiring is critical to proper operation.
7305 - Enable both infrared occupancy sensors
Enable both infrared occupancy sensors
8559 - To reconnect sensor cable, align connectors, push towards sensor, and turn co...
To reconnect sensor cable, align connectors, push towards sensor, and turn collar clockwise.



7474 - 7310 - Enable tamper switches; Remark:7451
7310 - Enable tamper switches
Enable tamper switches
7451 - Remove magnets and/or adhesive tape from door tamper switches.
Remove magnets and/or adhesive tape from door tamper switches.

7282 - 7254 - Xác nhận mạng đã được kết nối; Remark:7255
7254 - Xác nhận mạng đã được kết nối
Xác nhận mạng đã được kết nối
7255 - Liên lạc với cán bộ vận hành để xác nhận liên lạc đã được thiết lập lại giữa RPM...
Liên lạc với cán bộ vận hành để xác nhận liên lạc đã được thiết lập lại giữa RPM và trạm cảnh báo trung tâm/trạm cảnh báo tại địa phương (central alarm station/local alarm station, CAS/LAS).
9385 - 319 - Thực hiện kiểm tra vận hành; Remark:9347
319 - Thực hiện kiểm tra vận hành
Thực hiện kiểm tra vận hành
9347 - DET-RPM-RAP-RM03 Kiểm định Vận hành máy RPM.
DET-RPM-RAP-RM03 Kiểm định Vận hành máy RPM.
7283 - 7256 - Đóng và khóa tất cả các cửa của máy RPM; Remark:
7256 - Đóng và khóa tất cả các cửa của máy RPM
Đóng và khóa tất cả các cửa của máy RPM
8260 - 8250 - Mở lại Làn; Remark:8249
8250 - Mở lại Làn
Mở lại Làn
8249 - Gỡ cọc tiêu giao thông màu cam
Gỡ cọc tiêu giao thông màu cam
7842 - 7820 - Báo cho cán bộ vận hành sau khi hoàn tất công việc bảo trì; Remark:
7820 - Báo cho cán bộ vận hành sau khi hoàn tất công việc bảo trì
Báo cho cán bộ vận hành sau khi hoàn tất công việc bảo trì
322 - 321 - Ghi lại các Hoạt động Bảo trì; Remark:
321 - Ghi lại các Hoạt động Bảo trì
Ghi lại các Hoạt động Bảo trì
2869 - 2585 - Ghi lại hoạt động bảo trì đã thực hiện; Remark:2866
2585 - Ghi lại hoạt động bảo trì đã thực hiện
Ghi lại hoạt động bảo trì đã thực hiện
2866 - Ghi lại kết quả quan sát, thời gian và kết quả trong Báo cáo Bảo trì Sửa chữa.
Ghi lại kết quả quan sát, thời gian và kết quả trong Báo cáo Bảo trì Sửa chữa.
4706 - 4705 - Gửi báo cáo; Remark:4864
4705 - Gửi báo cáo
Gửi báo cáo
4864 - Theo quy định của cấp quản lý hoặc nghĩa vụ ghi trong hợp đồng.
Theo quy định của cấp quản lý hoặc nghĩa vụ ghi trong hợp đồng.