DET-RPM-RAP-FC09
5882 - 545 - Contact Technical Support - Incomplete, Notes: 5881
10593 - 10084 - Replace Banner IR Occupancy Sensor - Formal Procedure, Notes: 9007
10091 - Note : Take care that you replace the barrel sensor with the appropriate spare. Blac...
Type
Note
Take care that you replace the barrel sensor with the appropriate spare. Black with black, yellow with yellow, and verify the label indicates that it is a receiver or transmitter, and that model numbers match.
10592 - Note : It would be extremely unlikely for both IR Occupancy sensor pairs to be fault...
Type
Note
It would be extremely unlikely for both IR Occupancy sensor pairs to be faulty at the same time. Recheck the sensor functionality and wiring carefully before deciding to replace IR occupancy sensors.
10084 - Replace Banner IR Occupancy Sensor
Replace Banner IR Occupancy Sensor
10604 - 10096 - OUT LEDs on Nanocontroller illuminated? - Decision, Notes: 10097
10096 - OUT LEDs on Nanocontroller illuminated?
OUT LEDs on Nanocontroller illuminated?
10605 - 10565 - Are Nanocontroller input voltages correct? - Decision, Notes: 10566
10565 - Are Nanocontroller input voltages correct?
Are Nanocontroller input voltages correct?
10607 - 10570 - +15 VDC present at IR sensors? - Decision, Notes: 9041
10606 - Note : In rare cases, the IR receivers are installed in the auxiliary pillar, and em...
Type
Note
In rare cases, the IR receivers are installed in the auxiliary pillar, and emitters in the control pillar. Spare wires in the crossover cable are used to send the occupancy signal to the nanocontroller.
10570 - +15 VDC present at IR sensors?
+15 VDC present at IR sensors?
No
10608 - 10578 - Both IN LEDs Illuminated? - Decision, Notes: 10097
10578 - Both IN LEDs Illuminated?
Both IN LEDs Illuminated?
10609 - 10581 - RUN and OK LEDs Illuminated? - Decision, Notes: 10097
10581 - RUN and OK LEDs Illuminated?
RUN and OK LEDs Illuminated?
10610 - 10584 - PWR LED on Nanocontroller Illuminated? - Decision, Notes: 10097
10584 - PWR LED on Nanocontroller Illuminated?
PWR LED on Nanocontroller Illuminated?
No
10611 - 9113 - Establish Initial conditions - Process, Notes: 9115
9113 - Establish Initial conditions
Establish Initial conditions
Note
Flowchart Title
Không có thông báo tốc độ