Last Updated: 06/19/2025 1:42 AM
The following table lists all the components that make up the document.
Title | Type | Status | Last Updated |
---|---|---|---|
Smiths Detection RadSeeker CS | Device
|
Published
|
06/04/2025 3:30 PM
|
5925 - 5924 - Prepare Calibration Source; Remark: | Procedure Step
|
Published
|
11/07/2022 1:09 PM
|
5924 - Prepare Calibration Source | Instruction
|
Published
|
11/07/2022 1:09 PM
|
5923 - 5922 - Position Eu-152 calibration source; Remark:5921 | Procedure Step
|
Published
|
11/07/2022 1:21 PM
|
5922 - Position Eu-152 calibration source | Instruction
|
Published
|
11/07/2022 1:10 PM
|
5921 - Position Eu-152 source in front of the detector. | Remark
|
Published
|
11/07/2022 1:21 PM
|
5920 - 5919 - Calibrate Instrument; Remark: | Procedure Step
|
Published
|
11/07/2022 1:22 PM
|
5919 - Calibrate Instrument | Instruction
|
Published
|
11/07/2022 1:22 PM
|
5914 - 5913 - Enter Advanced Mode; Remark:5912 | Procedure Step
|
Published
|
11/07/2022 1:24 PM
|
5913 - Enter Advanced Mode | Instruction
|
Published
|
11/07/2022 1:23 PM
|
5912 - Select Menu from the Detect screen. Scroll down to E... | Remark
|
Published
|
11/07/2022 1:24 PM
|
5915 - 5911 - Enter password; Remark:5910 | Procedure Step
|
Published
|
11/07/2022 1:26 PM
|
5911 - Enter password | Instruction
|
Published
|
11/07/2022 1:25 PM
|
5910 - Enter default Nuclear Smuggling Detection and Deterrence (NSDD) password | Remark
|
Published
|
11/07/2022 1:26 PM
|
5916 - 5592 - Enter Service Mode; Remark:5909 | Procedure Step
|
Published
|
11/07/2022 1:28 PM
|
5592 - Enter Service Mode | Instruction
|
Published
|
10/31/2022 11:37 AM
|
5909 - Select Enter Service Mode from the Advanced Mode menu. | Remark
|
Published
|
11/07/2022 1:28 PM
|
5917 - 5908 - Start calibration; Remark:5907 | Procedure Step
|
Published
|
11/07/2022 1:31 PM
|
5908 - Start calibration | Instruction
|
Published
|
11/07/2022 1:30 PM
|
5907 - Select Calibrate Detector. Wait several minutes for the cali... | Remark
|
Published
|
11/07/2022 1:31 PM
|
5918 - 5906 - Confirm completion; Remark:5905 | Procedure Step
|
Published
|
11/07/2022 1:32 PM
|
5906 - Confirm completion | Instruction
|
Published
|
11/07/2022 1:32 PM
|
5905 - The Calibrated message will appear indicating calibration is... | Remark
|
Published
|
11/07/2022 1:32 PM
|
5904 - 5903 - Prepare Instrument for Use; Remark: | Procedure Step
|
Published
|
11/07/2022 1:33 PM
|
5903 - Prepare Instrument for Use | Instruction
|
Published
|
11/07/2022 1:33 PM
|
5900 - 5899 - Exit Service Mode; Remark:5898 | Procedure Step
|
Published
|
11/07/2022 1:35 PM
|
5899 - Exit Service Mode | Instruction
|
Published
|
11/07/2022 1:34 PM
|
5898 - Return Back to Service Mode options. | Remark
|
Published
|
11/07/2022 1:35 PM
|
5901 - 5897 - Select Exit Advanced Mode; Remark:5957 | Procedure Step
|
Published
|
11/07/2022 1:36 PM
|
5897 - Select Exit Advanced Mode | Instruction
|
Published
|
11/07/2022 1:36 PM
|
5957 - IO RadSeeker Detect Screen Exit Advanced Mode | Remark
|
Published
|
11/15/2022 11:43 AM
|
5902 - 5896 - Restart Instrument; Remark: | Procedure Step
|
Published
|
11/07/2022 1:37 PM
|
5896 - Restart Instrument | Instruction
|
Published
|
11/07/2022 1:37 PM
|
322 - 321 - Document maintenance actions; Remark: | Procedure Step
|
Published
|
06/17/2021 9:49 AM
|
321 - Document maintenance actions | Instruction
|
Published
|
04/21/2025 11:19 AM
|
2869 - 2585 - Document maintenance performed; Remark:2866 | Procedure Step
|
Published
|
06/18/2021 5:58 PM
|
2585 - Document maintenance performed | Instruction
|
Published
|
07/09/2021 12:15 PM
|
2866 - Record observations, times, and results for the maintenance report. | Remark
|
Published
|
04/21/2025 11:39 AM
|
4706 - 4705 - Submit report; Remark:4864 | Procedure Step
|
Published
|
06/29/2022 9:50 AM
|
4705 - Submit report | Instruction
|
Published
|
06/29/2022 9:50 AM
|
4864 - As specified by management or contractual obligations. | Remark
|
Published
|
07/28/2022 1:36 PM
|
Corrective Maintenance Procedure | Document Type
|
Published
|
03/02/2020 3:32 PM
|
minutes | Duration
|
Published
|
05/26/2022 11:41 AM
|
As Needed | Frequency
|
Published
|
04/01/2020 11:36 AM
|
Technician 2 | Skill Level
|
Published
|
04/09/2020 1:17 AM
|
None | Tools
|
Published
|
05/06/2020 9:50 PM
|
radseeker_di_front_rad_symbol.jpg | រូបភាព
|
Published
|
10/10/2023 12:32 AM
|
radseeker_ui_detect_screen_menu.jpg | រូបភាព
|
Published
|
10/10/2023 12:20 AM
|
radseeker_ui_detect_screen_enter_arrow.jpg | រូបភាព
|
Published
|
10/10/2023 12:22 AM
|
radseeker_ui_detect_screen_password.jpg | រូបភាព
|
Published
|
10/10/2023 12:14 AM
|
radseeker_ui_detect_screen_enter_service_mode.jpg | រូបភាព
|
Published
|
10/10/2023 12:26 AM
|
radseeker_ui_detect_screen_calibrate_detector.jpg | រូបភាព
|
Published
|
10/10/2023 12:27 AM
|
radseeker_ui_detect_screen_calibrated.jpg | រូបភាព
|
Published
|
10/10/2023 12:26 AM
|
radseeker_ui_detect_screen_back_left_arrow.jpg | រូបភាព
|
Published
|
10/10/2023 12:27 AM
|
radseeker_ui_detect_screen_back.jpg | រូបភាព
|
Published
|
10/10/2023 12:28 AM
|
radseeker_ui_detect_screen_exit_advanced_mode.jpg | រូបភាព
|
Published
|
10/10/2023 12:21 AM
|
This procedure describes how to perform an energy calibration on the RadSeeker. This is only required following some corrective maintenance procedures. It is not required as a routine maintenance procedure as with other radiation detection instruments.
Prior to arrival, notify operators concerning expected work and duration.
5925 - 5924 - Prepare Calibration Source; Remark:
5924 - Prepare Calibration Source
Prepare Calibration Source
5923 - 5922 - Position Eu-152 calibration source; Remark:5921
5922 - Position Eu-152 calibration source
Position Eu-152 calibration source
5921 - Position Eu-152 source in front of the detector.
Position Eu-152 source in front of the detector.

5920 - 5919 - Calibrate Instrument; Remark:
5919 - Calibrate Instrument
Calibrate Instrument
5914 - 5913 - Enter Advanced Mode; Remark:5912
5913 - Enter Advanced Mode
Enter Advanced Mode
5912 - Select Menu from the Detect screen. Scroll down to E...
Select Menu from the Detect screen. Scroll down to Enter Advanced Mode.


5915 - 5911 - Enter password; Remark:5910
5911 - Enter password
Enter password
5910 - Enter default Nuclear Smuggling Detection and Deterrence (NSDD) password
Enter default Nuclear Smuggling Detection and Deterrence (NSDD) password 31431. If incorrect, contact NSDD Technical Services.

5916 - 5592 - Enter Service Mode; Remark:5909
5592 - Enter Service Mode
Enter Service Mode
5909 - Select Enter Service Mode from the Advanced Mode menu.
Select Enter Service Mode from the Advanced Mode menu.

5917 - 5908 - Start calibration; Remark:5907
5908 - Start calibration
Start calibration
5907 - Select Calibrate Detector. Wait several minutes for the cali...
Select Calibrate Detector. Wait several minutes for the calibration process to complete.

5918 - 5906 - Confirm completion; Remark:5905
5906 - Confirm completion
Confirm completion
5905 - The Calibrated message will appear indicating calibration is...
The Calibrated message will appear indicating calibration is complete.


5904 - 5903 - Prepare Instrument for Use; Remark:
5903 - Prepare Instrument for Use
Prepare Instrument for Use
5900 - 5899 - Exit Service Mode; Remark:5898
5899 - Exit Service Mode
Exit Service Mode
5898 - Return Back to Service Mode options.
Return Back to Service Mode options.

5901 - 5897 - Select Exit Advanced Mode; Remark:5957
5897 - Select Exit Advanced Mode
Select Exit Advanced Mode
5902 - 5896 - Restart Instrument; Remark:
5896 - Restart Instrument
Restart Instrument
322 - 321 - Ghi lại các Hoạt động Bảo trì; Remark:
321 - Ghi lại các Hoạt động Bảo trì
Ghi lại các Hoạt động Bảo trì
2869 - 2585 - Ghi lại hoạt động bảo trì đã thực hiện; Remark:2866
2585 - Ghi lại hoạt động bảo trì đã thực hiện
Ghi lại hoạt động bảo trì đã thực hiện
2866 - Ghi lại kết quả quan sát, thời gian và kết quả trong Báo cáo Bảo trì Sửa chữa.
Ghi lại kết quả quan sát, thời gian và kết quả trong Báo cáo Bảo trì Sửa chữa.
4706 - 4705 - Gửi báo cáo; Remark:4864
4705 - Gửi báo cáo
Gửi báo cáo
4864 - Theo quy định của cấp quản lý hoặc nghĩa vụ ghi trong hợp đồng.
Theo quy định của cấp quản lý hoặc nghĩa vụ ghi trong hợp đồng.