Abbreviation
PG

RadSeeker CS Smiths Detection

Last Updated: 05/02/2025 1:37 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Smiths Detection RadSeeker CS
Device
Published
06/27/2024 12:54 PM
219 - Assicurarsi che non siano presenti sorgenti radioattive vicino allo strumento
Instruction
Published
04/12/2025 4:20 PM
7 - No Radiation symbol
Remark
Published
07/12/2021 1:34 PM
786 - 219 - Assicurarsi che non siano presenti sorgenti radioattive vicino allo strumento; Remark:7
Procedure Step
Published
04/20/2025 6:37 PM
614 - VERIFICARE che la batteria sia sufficientemente carica
Instruction
Published
04/06/2021 1:59 PM
2297 - IO RadSeeker 3 bar Battery
Remark
Published
10/19/2024 10:28 PM
2339 - 614 - VERIFICARE che la batteria sia sufficientemente carica; Remark:2297
Procedure Step
Published
07/27/2021 3:46 PM
220 - Accendere lo strumento
Instruction
Published
04/06/2025 7:00 PM
2298 - IO RadSeeker Button Pad Select Button Yellow Box
Remark
Published
10/21/2024 7:26 PM
2340 - 2985 - ACCENDERE lo strumento; Remark:2298
Procedure Step
Published
04/20/2025 9:48 PM
612 - ATTENDERE che lo strumento completi la sequenza di avvio
Instruction
Published
04/13/2025 6:38 PM
3484 - IO RadSeeker Detect Mode 217
Remark
Not translated
07/27/2021 3:51 PM
2341 - 612 - ATTENDERE che lo strumento completi la sequenza di avvio; Remark:3484
Procedure Step
Published
04/13/2025 5:38 PM
2338 - VERIFICARE che l'ADI (indicatore acustico del rateo di dose) sia attivo (spia re...
Instruction
Published
07/27/2021 3:56 PM
2324 - IO RadSeeker ADI Bar
Remark
Published
10/21/2024 7:33 PM
2343 - 2338 - VERIFICARE che l'ADI (indicatore acustico del rateo di dose) sia attivo (spia re...; Remark:2324
Procedure Step
Published
11/04/2020 5:06 PM
115 - RILEVARE vicino alla superficie dell'oggetto (5-10 cm)
Instruction
Published
06/13/2022 11:23 AM
2346 - 115 - RILEVARE vicino alla superficie dell'oggetto (5-10 cm); Remark:
Procedure Step
Published
11/04/2020 5:06 PM
617 - RILEVARE LENTAMENTE sull'intero oggetto (20 cm/secondo)
Instruction
Published
06/06/2022 12:17 PM
2309 - IO RadSeeker Raster Scan Box
Remark
Published
11/04/2020 7:37 AM
3491 - 617 - RILEVARE LENTAMENTE sull'intero oggetto (20 cm/secondo); Remark:2309
Procedure Step
Published
07/27/2021 4:56 PM
3080 - OSSERVARE la risposta dello strumento
Instruction
Published
07/12/2021 1:27 PM
3490 - IO RadSeeker Gamma Increase Graph
Remark
Not translated
07/27/2021 4:55 PM
3492 - 3080 - OSSERVARE la risposta dello strumento; Remark:3490
Procedure Step
Published
07/27/2021 4:56 PM
2345 - PREMERE INVIO per confermare gli allarmi
Instruction
Published
07/27/2021 4:12 PM
3485 - IO RadSeeker Gamma Alarm Acknowledge
Remark
Not translated
07/27/2021 4:08 PM
2347 - 2345 - PREMERE INVIO per confermare gli allarmi; Remark:3485
Procedure Step
Published
07/27/2021 4:13 PM
368 - Segnare le posizioni per ulteriori controlli
Instruction
Published
06/11/2021 9:23 AM
132 - Marking location for further investigation
Remark
Published
11/09/2024 3:37 PM
133 - 116 - MARCARE il/i punto/i interessato/i; Remark:132
Procedure Step
Published
04/20/2025 6:28 PM
625 - POSIZIONARE lo strumento vicino al punto di misurazione
Instruction
Published
04/06/2021 1:55 PM
2323 - IO RadSeeker Trefoil Box Identify
Remark
Published
11/04/2020 7:40 AM
2459 - 625 - POSIZIONARE lo strumento vicino al punto di misurazione; Remark:2323
Procedure Step
Published
06/09/2022 1:28 PM
2470 - PREMERE INVIO per avviare l'identificazione
Instruction
Published
07/27/2021 4:19 PM
3486 - IO RadSeeker StartID Small Menu
Remark
Published
10/21/2024 8:54 PM
2480 - 2470 - PREMERE INVIO per avviare l'identificazione; Remark:3486
Procedure Step
Published
07/27/2021 4:24 PM
2220 - Wait for measurement to complete
Instruction
Not translated
10/22/2020 11:15 AM
2321 - IO RadSeeker Collecting Spectrum Wait
Remark
Published
10/21/2024 8:36 PM
2481 - 626 - ATTENDERE il completamento dell'identificazione; Remark:2321
Procedure Step
Published
04/20/2025 12:43 PM
2472 - PREMERE INVIO per confermare gli allarmi
Instruction
Published
07/27/2021 4:28 PM
2320 - IO RadSeeker Alarm Acknowledge Threat
Remark
Published
10/21/2024 8:40 PM
2482 - 2472 - PREMERE INVIO per confermare gli allarmi; Remark:2320
Procedure Step
Published
11/04/2020 5:11 PM
628 - OSSERVARE i risultati dell'identificazione
Instruction
Published
04/06/2021 1:52 PM
2319 - IO RadSeeker Identify Isotope Co60
Remark
Published
10/21/2024 8:42 PM
2483 - 628 - OSSERVARE i risultati dell'identificazione; Remark:2319
Procedure Step
Published
11/04/2020 5:11 PM
2476 - DOCUMENTARE il numero dell'evento
Instruction
Published
07/27/2021 4:31 PM
3487 - IO RadSeeker Event Number
Remark
Not translated
07/27/2021 4:33 PM
3546 - 2476 - DOCUMENTARE il numero dell'evento; Remark:3487
Procedure Step
Published
08/03/2021 10:00 AM
3488 - PREMERE INVIO per tornare alla modalità Detect
Instruction
Published
07/27/2021 4:37 PM
3489 - IO RadSeeker Detect Small Menu
Remark
Not translated
07/27/2021 4:40 PM
2486 - 3488 - PREMERE INVIO per tornare alla modalità Detect; Remark:3489
Procedure Step
Published
07/27/2021 4:41 PM
2478 - SPEGNERE lo strumento - PREMERE E MANTENERE PREMUTO INVIO
Instruction
Published
07/27/2021 4:43 PM
2316 - IO RadSeeker Shutting Down
Remark
Published
11/04/2020 4:58 PM
2487 - 2478 - SPEGNERE lo strumento - PREMERE E MANTENERE PREMUTO INVIO; Remark:2316
Procedure Step
Published
11/04/2020 5:13 PM
2479-Promemoria : La temperatura deve essere superiore a -15°C perché lo strumento si avvii. Non u...
Annotation
Published
07/26/2021 7:32 AM
Guida tascabile
Document Type
Published
03/02/2020 3:32 PM
Promemoria
Annotation Type
Published
04/08/2020 12:21 PM
No Radiation Symbol
Image
Published
08/13/2024 2:56 PM
radseeker_di_battbar_000477.jpg
Image
Published
10/18/2023 4:32 PM
radseeker_di_selectmiddle_00473.jpg
Image
Published
10/20/2023 9:35 AM
radseeker_ui_modedetect_217cps_00467.jpg
Image
Published
10/20/2023 10:15 AM
radseeker_ui_adiselect_00471.jpg
Image
Published
10/20/2023 9:42 AM
radseeker_di_raster_000474.jpg
Image
Published
10/18/2023 4:43 PM
radseeker_ui_detect_11164cps_00653.jpg
Image
Published
10/20/2023 9:47 AM
radseeker_ui_gammaalarmack_233cps_00655.jpg
Image
Published
10/20/2023 9:48 AM
Mark_Source_Location_Trefoil
Image
Published
02/19/2023 10:54 AM
radseeker_di_pointident_000475.jpg
Image
Published
10/18/2023 4:40 PM
radseeker_ui_menustartid_button_00651.jpg
Image
Published
10/20/2023 10:11 AM
radseeker_ui_collectspec_00468.jpg
Image
Published
10/20/2023 9:46 AM
radseeker_ui_threatack_1025cps_00457.jpg
Image
Published
10/20/2023 10:22 AM
radseeker_ui_idco60_902cps_00465.jpg
Image
Published
10/20/2023 10:06 AM
radseeker_ui_eventid_00666.jpg
Image
Published
10/20/2023 9:47 AM
radseeker_ui_menudetect_button_00652.jpg
Image
Published
10/20/2023 10:09 AM
radseeker_ui_shut_00460.jpg
Image
Published
10/20/2023 10:19 AM

Dispositivo di rilevamento Rapiscan PRM-470 CG

Last Updated: 05/02/2025 1:34 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
219 - Assicurarsi che non siano presenti sorgenti radioattive vicino allo strumento
Instruction
Published
04/12/2025 4:20 PM
7 - No Radiation symbol
Remark
Published
07/12/2021 1:34 PM
786 - 219 - Assicurarsi che non siano presenti sorgenti radioattive vicino allo strumento; Remark:7
Procedure Step
Published
04/20/2025 6:37 PM
220 - Accendere lo strumento
Instruction
Published
04/06/2025 7:00 PM
2545 - IO PRM-470 Power Button Red Box
Remark
Published
10/29/2024 9:30 PM
139 - 2985 - ACCENDERE lo strumento; Remark:2545
Procedure Step
Published
04/20/2025 9:47 PM
612 - ATTENDERE che lo strumento completi la sequenza di avvio
Instruction
Published
04/13/2025 6:38 PM
679 - 612 - ATTENDERE che lo strumento completi la sequenza di avvio; Remark:
Procedure Step
Published
04/13/2025 6:33 PM
3077 - SELEZIONARE la modalità
Instruction
Published
07/12/2021 1:31 PM
10470 -
Remark
Not translated
12/01/2023 4:48 PM
3085 - 3077 - SELEZIONARE la modalità; Remark:3082
Procedure Step
Published
07/12/2021 1:41 PM
3078 - VERIFICARE che lo strumento sia in MODALITÀ SEARCH
Instruction
Published
07/12/2021 1:30 PM
751 - IO PRM-470 Search Mode 65 CPS Gamma
Remark
Published
10/29/2024 9:31 PM
3086 - 3078 - VERIFICARE che lo strumento sia in MODALITÀ SEARCH; Remark:751
Procedure Step
Published
07/12/2021 1:41 PM
115 - RILEVARE vicino alla superficie dell'oggetto (5-10 cm)
Instruction
Published
06/13/2022 11:23 AM
10467 -
Remark
Not translated
12/01/2023 4:53 PM
131 - 115 - RILEVARE vicino alla superficie dell'oggetto (5-10 cm); Remark:128
Procedure Step
Published
07/12/2021 1:42 PM
617 - RILEVARE LENTAMENTE sull'intero oggetto (20 cm/secondo)
Instruction
Published
06/06/2022 12:17 PM
3087 - 617 - RILEVARE LENTAMENTE sull'intero oggetto (20 cm/secondo); Remark:
Procedure Step
Published
07/12/2021 1:42 PM
3079 - PASSARE alla MODALITÀ FIND quando l'allarme è costante
Instruction
Published
07/12/2021 1:28 PM
3082 - IO PRM-470 Mode Button Red Box
Remark
Published
10/29/2024 9:32 PM
3088 - 3079 - PASSARE alla MODALITÀ FIND quando l'allarme è costante; Remark:3082
Procedure Step
Published
07/12/2021 1:43 PM
3080 - OSSERVARE la risposta dello strumento
Instruction
Published
07/12/2021 1:27 PM
10461 -
Remark
Not translated
12/01/2023 5:04 PM
3089 - 3080 - OSSERVARE la risposta dello strumento; Remark:3083
Procedure Step
Published
07/12/2021 1:43 PM
368 - Segnare le posizioni per ulteriori controlli
Instruction
Published
06/11/2021 9:23 AM
132 - Marking location for further investigation
Remark
Published
11/09/2024 3:37 PM
133 - 116 - MARCARE il/i punto/i interessato/i; Remark:132
Procedure Step
Published
04/20/2025 6:28 PM
117 - DOCUMENTARE i risultati
Instruction
Published
07/12/2021 1:26 PM
136 - 117 - DOCUMENTARE i risultati; Remark:
Procedure Step
Published
07/12/2021 1:44 PM
313 - Spegnere lo strumento
Instruction
Published
07/23/2021 2:41 PM
3090 - 2997 - SPEGNERE lo strumento; Remark:2545
Procedure Step
Published
01/14/2022 5:30 PM
120-Promemoria : Si raccomanda di eseguire una prova di funzionamento giornaliera prima dell'uso....
Annotation
Published
07/12/2021 1:23 PM
121-Promemoria : Se lo strumento non si muove per 60 secondi, passerà alla modalità di fondo.
Annotation
Published
07/12/2021 1:22 PM
3075-Promemoria : Non utilizzare lo strumento a temperature inferiori a 0°C o superiori a 38°C.
Annotation
Published
07/12/2021 1:21 PM
3076-Promemoria : Spegnere lo strumento prima di collegarlo al caricatore.
Annotation
Published
07/12/2021 1:20 PM
Guida tascabile
Document Type
Published
03/02/2020 3:32 PM
Promemoria
Annotation Type
Published
04/08/2020 12:21 PM
No Radiation Symbol
Image
Published
08/13/2024 2:56 PM
PRM-470_Partial_Power_Button_Red_Highlight.png
Image
Published
06/18/2021 6:28 PM
Rapiscan PRM-470 CGN Select Mode
Image
Published
12/01/2023 5:15 PM
PRM-470 Display SEARCH
Image
Published
04/01/2021 11:22 PM
Rapiscan PRM-470 CGN survey close to surface
Image
Published
12/01/2023 5:15 PM
PRM-470_Partial-View_S-F-Button_RED-Highlight.png
Image
Published
04/01/2021 11:22 PM
Rapiscan PRM-470 CGN Instrument response Find Mode
Image
Published
12/01/2023 5:15 PM
Mark_Source_Location_Trefoil
Image
Published
02/19/2023 10:54 AM