Needle nose pliers

PRM-470 PRCB-472 Board Replacement

Last Updated: 05/12/2025 1:55 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Rapiscan PRM-470 CG
Device
Published
10/28/2024 3:40 PM
Rapiscan PRM-470 CGN
Device
Published
10/28/2024 3:33 PM
247 - 257 - Prepare instrument; Remark:
Procedure Step
Published
04/11/2025 9:08 PM
257 - Prepare instrument
Instruction
Published
04/11/2025 9:07 PM
607 - 205 - Disconnect charger; Remark:
Procedure Step
Published
07/23/2021 2:42 PM
205 - Disconnect charger
Instruction
Published
07/23/2021 2:42 PM
260 - 313 - Power off instrument; Remark:
Procedure Step
Published
07/23/2021 2:43 PM
313 - Power off instrument
Instruction
Published
07/23/2021 2:41 PM
275 - 65 - Uvolněte čtyři (4) šrouby v krytu; Remark:264
Procedure Step
Published
07/26/2021 12:42 PM
65 - Loosen four (4) cover screws
Instruction
Published
07/22/2021 12:38 PM
264 - Use a medium Phillips (PH2) screwdriver. Screws do not need to be completely ...
Remark
Published
07/20/2021 3:59 PM
263 - 262 - Odstraňte kryt přístroje; Remark:413
Procedure Step
Published
08/11/2021 1:41 PM
2771 - Note : There are high-voltage detector circuit boards inside the instrument; however...
Annotation
Published
10/04/2022 11:06 AM
262 - Remove instrument cover
Instruction
Published
07/20/2021 3:35 PM
413 - PRM-470 Remove Instrument Cover
Remark
Published
11/01/2024 8:32 PM
276 - 266 - Vyhledejte přípojku baterie; Remark:265
Procedure Step
Published
08/11/2021 3:07 PM
3033 - Note : PRM-470 CGN models have an additional board and connectors not shown in remar...
Annotation
Published
10/04/2022 11:07 AM
266 - Locate battery connection
Instruction
Published
07/20/2021 3:36 PM
265 - Battery connection is labeled 1.
Remark
Published
08/07/2021 11:16 AM
271 - 270 - Odpojte baterii; Remark:414
Procedure Step
Published
08/11/2021 1:42 PM
1345 - Note : It is good practice to ensure all cables and connectors are labeled prior to ...
Annotation
Published
10/04/2022 11:08 AM
270 - Disconnect battery
Instruction
Published
07/20/2021 3:37 PM
414 - PRM-470_Disconnect_battery
Remark
Published
11/02/2024 1:21 PM
443 - 442 - Odpojte zbývající konektory; Remark:
Procedure Step
Published
08/11/2021 1:43 PM
442 - Disconnect remaining connectors
Instruction
Published
07/22/2021 12:39 PM
3399 - 3398 - Uninstall GHA-472 board; Remark:
Procedure Step
Published
08/12/2021 7:16 AM
3398 - Uninstall GHA-472 board
Instruction
Published
08/07/2021 10:49 AM
478 - 476 - Remove mounting nut; Remark:477
Procedure Step
Published
08/11/2021 1:54 PM
476 - Remove mounting nut
Instruction
Published
08/07/2021 10:57 AM
477 - PRM-470 - Removing GHA-472 mounting nut
Remark
Published
11/02/2024 2:00 PM
481 - 479 - Vyjměte desku GHA-472; Remark:480
Procedure Step
Published
08/11/2021 1:55 PM
479 - Remove GHA-472 board
Instruction
Published
07/22/2021 12:56 PM
480 - Gently pry up the GHA-472 board from the PRCB-472 board.
Remark
Published
07/22/2021 1:13 PM
618 - 615 - Uninstall PRCB-472 board; Remark:
Procedure Step
Published
08/12/2021 7:16 AM
615 - Uninstall PRCB-472 board
Instruction
Published
08/07/2021 11:00 AM
886 - 445 - Remove four (4) mounting screws; Remark:885
Procedure Step
Published
08/12/2021 7:19 AM
445 - Remove four (4) mounting screws
Instruction
Published
07/22/2021 12:41 PM
885 - Use a small Phillips (PH1) screwdriver. Retain screws.
Remark
Published
08/07/2021 11:18 AM
767 - 449 - Zvedněte okraj desky PRCB-472, abyste se dostali pod ni; Remark:766
Procedure Step
Published
08/12/2021 7:19 AM
447 - Caution : Do not damage ribbon cable attached to the underside of PRCB-472.
Annotation
Published
10/04/2022 11:11 AM
449 - Raise edge of PRCB-472 board to access underside
Instruction
Published
07/22/2021 12:42 PM
766 - IO Lift PRCB-472 from PRM-470 cover No Gamma
Remark
Published
11/02/2024 3:40 PM
453 - 452 - Odpojte konektor překryvného tlačítka; Remark:451
Procedure Step
Published
08/11/2021 1:48 PM
452 - Disconnect overlay button connector
Instruction
Published
07/22/2021 12:43 PM
451 - PRM-470 Display circuit board
Remark
Published
11/02/2024 3:35 PM
3397 - 3395 - Označte vadnou součástku; Remark:3396
Procedure Step
Published
07/21/2024 6:59 AM
3395 - Label faulty component
Instruction
Published
08/07/2021 11:07 AM
3396 - Use tag or tape. Include date of removal, description of failure symptoms, co...
Remark
Published
08/09/2021 11:35 AM
645 - 644 - Install new PRCB-472 board; Remark:
Procedure Step
Published
08/12/2021 7:15 AM
644 - Install new PRCB-472 board
Instruction
Published
08/07/2021 11:08 AM
648 - 647 - Set LCD assembly in place; Remark:646
Procedure Step
Published
08/12/2021 7:14 AM
647 - Set LCD assembly in place
Instruction
Published
08/07/2021 11:09 AM
646 - The LEDs on either side of the display might need to be slightly spread apart...
Remark
Published
08/09/2021 11:36 AM
668 - 649 - Zašroubujte zpět čtyři (4) montážní šrouby; Remark:663
Procedure Step
Published
08/12/2021 7:14 AM
649 - Reinstall four (4) mounting screws
Instruction
Published
08/07/2021 11:10 AM
663 - Use a small Phillips (PH1) screwdriver.
Remark
Published
08/09/2021 11:37 AM
465 - 463 - Znovu připojte konektor překryvného tlačítka; Remark:464
Procedure Step
Published
08/11/2021 1:51 PM
462 - Caution : Correct placement of connectors and wiring is critical to proper operation.
Annotation
Published
09/28/2023 2:13 PM
463 - Reconnect overlay button connector
Instruction
Published
07/22/2021 12:50 PM
464 - PRM-470 - Connecting ribbon cable to overlay button connector
Remark
Published
11/02/2024 3:35 PM
768 - 468 - Uložte desku PRCB-472 na montážní tyčinky; Remark:765
Procedure Step
Published
08/12/2021 7:13 AM
468 - Set PRCB-472 board over mounting posts
Instruction
Published
07/22/2021 12:52 PM
765 - Position overlay ribbon cable to avoid catching between PRCB-472 and mounting...
Remark
Published
08/09/2021 11:59 AM
473 - 471 - Zašroubujte zpět čtyři (4) montážní šrouby; Remark:472
Procedure Step
Published
08/11/2021 1:53 PM
471 - Reinstall four (4) mounting screws
Instruction
Published
07/22/2021 12:53 PM
472 - Use a small Phillips (PH1) screwdriver.
Remark
Published
07/22/2021 1:13 PM
484 - 482 - Replace GHA-472 board; Remark:483
Procedure Step
Published
08/11/2021 1:55 PM
482 - Replace GHA-472 board
Instruction
Published
07/22/2021 12:56 PM
483 - Verify connectors are correctly aligned then press down.
Remark
Published
07/22/2021 1:14 PM
490 - 488 - Přimontujte zpět montážní matici desky GHA-472; Remark:489
Procedure Step
Published
08/11/2021 1:56 PM
504 - Caution : Do not overtighten the mounting nut.
Annotation
Published
10/04/2022 11:11 AM
488 - Reinstall GHA-472 board mounting nut
Instruction
Published
07/22/2021 12:57 PM
489 - PRM-470 - Location of GHA-472 mounting nut
Remark
Published
11/02/2024 2:01 PM
684 - 683 - Finish instrument assembly; Remark:
Procedure Step
Published
08/12/2021 7:13 AM
683 - Finish instrument assembly
Instruction
Published
08/07/2021 11:11 AM
500 - 498 - Reconnect all connectors except battery; Remark:499
Procedure Step
Published
08/11/2021 2:02 PM
498 - Reconnect all connectors except battery
Instruction
Published
07/22/2021 1:02 PM
499 - Do not connect location 1.
Remark
Published
07/22/2021 1:17 PM
503 - 305 - Opět zapojte baterii; Remark:502
Procedure Step
Published
08/11/2021 2:03 PM
305 - Reconnect battery
Instruction
Published
07/29/2021 3:48 PM
502 - PRM-470 - Reconnect battery at position 1
Remark
Published
11/02/2024 3:36 PM
308 - 307 - Vraťte přední kryt na místo; Remark:
Procedure Step
Published
08/11/2021 2:03 PM
304 - Caution : Ensure all wiring is inside the instrument while replacing cover.
Annotation
Published
10/04/2022 11:10 AM
307 - Replace front cover
Instruction
Published
07/20/2021 3:57 PM
310 - 309 - Utáhněte čtyři (4) šrouby v krytu; Remark:417
Procedure Step
Published
08/11/2021 2:04 PM
569 - Caution : Do not overtighten screws.
Annotation
Published
06/16/2021 2:31 PM
309 - Tighten four (4) cover screws
Instruction
Published
07/22/2021 1:02 PM
417 - Use a medium Phillips (PH2) screwdriver.
Remark
Published
07/22/2021 1:18 PM
320 - 319 - Perform operational test; Remark:347
Procedure Step
Published
08/12/2021 7:12 AM
319 - Perform operational test
Instruction
Published
06/10/2021 8:31 PM
347 - Perform DET-HHD-RAP-RM01 PRM-470 Operational Test.
Remark
Published
07/21/2021 12:22 PM
322 - 321 - Document maintenance actions; Remark:
Procedure Step
Published
06/17/2021 9:49 AM
321 - Document maintenance actions
Instruction
Published
04/21/2025 11:19 AM
2869 - 2585 - Document maintenance performed; Remark:2866
Procedure Step
Published
06/18/2021 5:58 PM
2585 - Document maintenance performed
Instruction
Published
07/09/2021 12:15 PM
2866 - Record observations, times, and results for the maintenance report.
Remark
Published
04/21/2025 11:39 AM
4706 - 4705 - Submit report; Remark:4864
Procedure Step
Published
06/29/2022 9:50 AM
4705 - Submit report
Instruction
Published
06/29/2022 9:50 AM
4864 - As specified by management or contractual obligations.
Remark
Published
07/28/2022 1:36 PM
Corrective Maintenance Procedure
Document Type
Published
03/02/2020 3:32 PM
20 minutes
Duration
Published
05/18/2020 5:44 PM
As Needed
Frequency
Published
04/01/2020 11:36 AM
Note
Annotation Type
Published
03/02/2020 3:25 PM
Caution
Annotation Type
Published
03/02/2020 3:24 PM
Technician 2
Skill Level
Published
04/09/2020 1:17 AM
Medium Phillips (PH2) screwdriver
Tools
Published
04/24/2020 4:40 PM
Small Phillips (PH1) screwdriver
Tools
Published
05/14/2020 2:48 PM
5-mm (1/4 inch) nut driver or socket
Tools
Published
05/14/2020 3:21 PM
Needle nose pliers
Tools
Published
05/06/2020 4:10 PM
PRM470_Remove_Screws_Top_Case
Image
Published
05/08/2020 6:05 PM
PRM-470_di_CGN_open_00536
Image
Published
02/19/2023 11:26 AM
PRM470_Battery_connection_is_labeled_1
Image
Published
02/19/2023 10:40 AM
PRM-470_Disconnect_battery
Image
Published
05/09/2020 8:40 PM
PRM-470 - GHA-472 mounting nut location
Image
Published
02/19/2023 11:37 AM
PRM-470 - GHA-472 mounting nut removal
Image
Published
05/12/2020 1:29 PM
PRM-470 - Removing GHA-472 board
Image
Published
05/12/2020 1:40 PM
PRM-470_Re-install_four_mounting_screws_no_gamma
Image
Published
02/19/2023 11:10 AM
PRM-470_Raise_edge_of_PRCB-472_board_no_gamma
Image
Published
02/19/2023 11:12 AM
PRM-470 Remove ribbon cable from PRCB-472 LCD Functional
Image
Published
05/20/2020 10:03 AM
PRM-470 Install LCD assembly onto PRCB-472_with_Posts
Image
Published
05/20/2020 9:45 AM
PRM-470 - Remove four LCD assembly mounting screws_PRCB-472 side
Image
Published
05/15/2020 2:09 PM
PRM-470 - Connecting ribbon cable to overlay button connector
Image
Published
05/12/2020 12:56 PM
PRM-470_Set_PRCB-472_board_no_gamma
Image
Published
02/19/2023 11:16 AM
Remove metal brackets
Image
Published
09/08/2023 2:50 PM
Remove metal brackets 2
Image
Published
09/08/2023 2:51 PM
PRM-470 - Re-seating GHA-472 board
Image
Published
05/12/2020 1:47 PM
PRM-470 - Re-seating the GHA-472 board
Image
Published
05/12/2020 1:53 PM
PRM-470 - GHA-472 mounting nut location
Image
Published
05/12/2020 2:00 PM
PRM-470_Reconnect_battery
Image
Published
05/10/2020 8:16 PM
PRM-470_Tighten_4_cover_screws
Image
Published
05/10/2020 8:22 PM

PRM-470 GHA-472 Board Replacement

Last Updated: 05/12/2025 1:54 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Rapiscan PRM-470 CG
Device
Published
10/28/2024 3:40 PM
Rapiscan PRM-470 CGN
Device
Published
10/28/2024 3:33 PM
247 - 257 - Prepare instrument; Remark:
Procedure Step
Published
04/11/2025 9:08 PM
257 - Prepare instrument
Instruction
Published
04/11/2025 9:07 PM
607 - 205 - Disconnect charger; Remark:
Procedure Step
Published
07/23/2021 2:42 PM
205 - Disconnect charger
Instruction
Published
07/23/2021 2:42 PM
314 - 313 - Power off instrument; Remark:
Procedure Step
Published
08/12/2021 6:54 AM
313 - Power off instrument
Instruction
Published
07/23/2021 2:41 PM
275 - 65 - Uvolněte čtyři (4) šrouby v krytu; Remark:264
Procedure Step
Published
07/26/2021 12:42 PM
65 - Loosen four (4) cover screws
Instruction
Published
07/22/2021 12:38 PM
264 - Use a medium Phillips (PH2) screwdriver. Screws do not need to be completely ...
Remark
Published
07/20/2021 3:59 PM
263 - 262 - Odstraňte kryt přístroje; Remark:413
Procedure Step
Published
08/11/2021 1:41 PM
2771 - Note : There are high-voltage detector circuit boards inside the instrument; however...
Annotation
Published
10/04/2022 11:06 AM
262 - Remove instrument cover
Instruction
Published
07/20/2021 3:35 PM
413 - PRM-470 Remove Instrument Cover
Remark
Published
11/01/2024 8:32 PM
267 - 266 - Vyhledejte přípojku baterie; Remark:272
Procedure Step
Published
08/11/2021 1:42 PM
3033 - Note : PRM-470 CGN models have an additional board and connectors not shown in remar...
Annotation
Published
10/04/2022 11:07 AM
266 - Locate battery connection
Instruction
Published
07/20/2021 3:36 PM
272 - Battery connection is labeled 1.
Remark
Published
07/21/2021 12:11 PM
271 - 270 - Odpojte baterii; Remark:414
Procedure Step
Published
08/11/2021 1:42 PM
1345 - Note : It is good practice to ensure all cables and connectors are labeled prior to ...
Annotation
Published
10/04/2022 11:08 AM
270 - Disconnect battery
Instruction
Published
07/20/2021 3:37 PM
414 - PRM-470_Disconnect_battery
Remark
Published
11/02/2024 1:21 PM
443 - 442 - Odpojte zbývající konektory; Remark:
Procedure Step
Published
08/11/2021 1:43 PM
442 - Disconnect remaining connectors
Instruction
Published
07/22/2021 12:39 PM
571 - 570 - Uninstall faulty GHA-472; Remark:
Procedure Step
Published
08/12/2021 6:55 AM
570 - Uninstall faulty GHA-472
Instruction
Published
08/11/2021 4:34 PM
478 - 476 - Remove mounting nut; Remark:477
Procedure Step
Published
08/11/2021 1:54 PM
476 - Remove mounting nut
Instruction
Published
08/07/2021 10:57 AM
477 - PRM-470 - Removing GHA-472 mounting nut
Remark
Published
11/02/2024 2:00 PM
481 - 479 - Vyjměte desku GHA-472; Remark:480
Procedure Step
Published
08/11/2021 1:55 PM
479 - Remove GHA-472 board
Instruction
Published
07/22/2021 12:56 PM
480 - Gently pry up the GHA-472 board from the PRCB-472 board.
Remark
Published
07/22/2021 1:13 PM
741 - 740 - Install new GHA-472 board; Remark:
Procedure Step
Published
08/12/2021 6:56 AM
740 - Install new GHA-472 board
Instruction
Published
08/11/2021 4:35 PM
484 - 482 - Replace GHA-472 board; Remark:483
Procedure Step
Published
08/11/2021 1:55 PM
482 - Replace GHA-472 board
Instruction
Published
07/22/2021 12:56 PM
483 - Verify connectors are correctly aligned then press down.
Remark
Published
07/22/2021 1:14 PM
744 - 743 - Přišroubujte zpět montážní matici; Remark:489
Procedure Step
Published
08/12/2021 6:56 AM
504 - Caution : Do not overtighten the mounting nut.
Annotation
Published
10/04/2022 11:11 AM
743 - Reinstall mounting nut
Instruction
Published
08/11/2021 4:36 PM
489 - PRM-470 - Location of GHA-472 mounting nut
Remark
Published
11/02/2024 2:01 PM
303 - 302 - Reassemble instrument; Remark:
Procedure Step
Published
10/07/2022 1:49 PM
302 - Reassemble instrument
Instruction
Published
06/16/2021 11:28 PM
500 - 498 - Reconnect all connectors except battery; Remark:499
Procedure Step
Published
08/11/2021 2:02 PM
498 - Reconnect all connectors except battery
Instruction
Published
07/22/2021 1:02 PM
499 - Do not connect location 1.
Remark
Published
07/22/2021 1:17 PM
306 - 305 - Reconnect battery; Remark:416
Procedure Step
Published
08/11/2021 3:11 PM
305 - Reconnect battery
Instruction
Published
07/29/2021 3:48 PM
416 - PRM-470 Battery Replacement - Reconnect battery
Remark
Published
11/02/2024 2:02 PM
308 - 307 - Vraťte přední kryt na místo; Remark:
Procedure Step
Published
08/11/2021 2:03 PM
304 - Caution : Ensure all wiring is inside the instrument while replacing cover.
Annotation
Published
10/04/2022 11:10 AM
307 - Replace front cover
Instruction
Published
07/20/2021 3:57 PM
310 - 309 - Utáhněte čtyři (4) šrouby v krytu; Remark:417
Procedure Step
Published
08/11/2021 2:04 PM
569 - Caution : Do not overtighten screws.
Annotation
Published
06/16/2021 2:31 PM
309 - Tighten four (4) cover screws
Instruction
Published
07/22/2021 1:02 PM
417 - Use a medium Phillips (PH2) screwdriver.
Remark
Published
07/22/2021 1:18 PM
747 - 746 - Perform gamma alignment; Remark:745
Procedure Step
Published
08/12/2021 6:56 AM
746 - Perform gamma alignment
Instruction
Published
08/11/2021 4:37 PM
745 - An alignment is required following replacement of the gamma board or the gamm...
Remark
Published
08/12/2021 7:00 AM
322 - 321 - Document maintenance actions; Remark:
Procedure Step
Published
06/17/2021 9:49 AM
321 - Document maintenance actions
Instruction
Published
04/21/2025 11:19 AM
2869 - 2585 - Document maintenance performed; Remark:2866
Procedure Step
Published
06/18/2021 5:58 PM
2585 - Document maintenance performed
Instruction
Published
07/09/2021 12:15 PM
2866 - Record observations, times, and results for the maintenance report.
Remark
Published
04/21/2025 11:39 AM
4706 - 4705 - Submit report; Remark:4864
Procedure Step
Published
06/29/2022 9:50 AM
4705 - Submit report
Instruction
Published
06/29/2022 9:50 AM
4864 - As specified by management or contractual obligations.
Remark
Published
07/28/2022 1:36 PM
Corrective Maintenance Procedure
Document Type
Published
03/02/2020 3:32 PM
20 minutes
Duration
Published
05/18/2020 5:44 PM
As Needed
Frequency
Published
04/01/2020 11:36 AM
Note
Annotation Type
Published
03/02/2020 3:25 PM
Caution
Annotation Type
Published
03/02/2020 3:24 PM
Technician 2
Skill Level
Published
04/09/2020 1:17 AM
Medium Phillips (PH2) screwdriver
Tools
Published
04/24/2020 4:40 PM
Small Phillips (PH1) screwdriver
Tools
Published
05/14/2020 2:48 PM
5-mm (1/4 inch) nut driver or socket
Tools
Published
05/14/2020 3:21 PM
Needle nose pliers
Tools
Published
05/06/2020 4:10 PM
PRM470_Remove_Screws_Top_Case
Image
Published
05/08/2020 6:05 PM
PRM-470_di_CGN_open_00536
Image
Published
02/19/2023 11:26 AM
Battery_connection_is_labeled_1
Image
Published
02/19/2023 10:46 AM
PRM-470_Disconnect_battery
Image
Published
05/09/2020 8:40 PM
PRM-470 - GHA-472 mounting nut location
Image
Published
02/19/2023 11:37 AM
PRM-470 - GHA-472 mounting nut removal
Image
Published
05/12/2020 1:29 PM
PRM-470 - Removing GHA-472 board
Image
Published
05/12/2020 1:40 PM
PRM-470 - Re-seating GHA-472 board
Image
Published
05/12/2020 1:47 PM
PRM-470 - Re-seating the GHA-472 board
Image
Published
05/12/2020 1:53 PM
PRM-470 - GHA-472 mounting nut location
Image
Published
05/12/2020 2:00 PM
PRM470_Battery_connection_is_labeled_1
Image
Published
02/19/2023 10:40 AM
PRM-470_Reconnect_battery
Image
Published
05/10/2020 8:16 PM
PRM-470_Tighten_4_cover_screws
Image
Published
05/10/2020 8:22 PM

PRM-470 Check Connections and Reseat Boards

Last Updated: 05/12/2025 1:54 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Rapiscan PRM-470 CG
Device
Published
10/28/2024 3:40 PM
Rapiscan PRM-470 CGN
Device
Published
10/28/2024 3:33 PM
247 - 257 - Prepare instrument; Remark:
Procedure Step
Published
04/11/2025 9:08 PM
257 - Prepare instrument
Instruction
Published
04/11/2025 9:07 PM
607 - 205 - Disconnect charger; Remark:
Procedure Step
Published
07/23/2021 2:42 PM
205 - Disconnect charger
Instruction
Published
07/23/2021 2:42 PM
260 - 313 - Power off instrument; Remark:
Procedure Step
Published
07/23/2021 2:43 PM
313 - Power off instrument
Instruction
Published
07/23/2021 2:41 PM
275 - 65 - Uvolněte čtyři (4) šrouby v krytu; Remark:264
Procedure Step
Published
07/26/2021 12:42 PM
65 - Loosen four (4) cover screws
Instruction
Published
07/22/2021 12:38 PM
264 - Use a medium Phillips (PH2) screwdriver. Screws do not need to be completely ...
Remark
Published
07/20/2021 3:59 PM
263 - 262 - Odstraňte kryt přístroje; Remark:413
Procedure Step
Published
08/11/2021 1:41 PM
2771 - Note : There are high-voltage detector circuit boards inside the instrument; however...
Annotation
Published
10/04/2022 11:06 AM
262 - Remove instrument cover
Instruction
Published
07/20/2021 3:35 PM
413 - PRM-470 Remove Instrument Cover
Remark
Published
11/01/2024 8:32 PM
267 - 266 - Vyhledejte přípojku baterie; Remark:272
Procedure Step
Published
08/11/2021 1:42 PM
3033 - Note : PRM-470 CGN models have an additional board and connectors not shown in remar...
Annotation
Published
10/04/2022 11:07 AM
266 - Locate battery connection
Instruction
Published
07/20/2021 3:36 PM
272 - Battery connection is labeled 1.
Remark
Published
07/21/2021 12:11 PM
271 - 270 - Odpojte baterii; Remark:414
Procedure Step
Published
08/11/2021 1:42 PM
1345 - Note : It is good practice to ensure all cables and connectors are labeled prior to ...
Annotation
Published
10/04/2022 11:08 AM
270 - Disconnect battery
Instruction
Published
07/20/2021 3:37 PM
414 - PRM-470_Disconnect_battery
Remark
Published
11/02/2024 1:21 PM
443 - 442 - Odpojte zbývající konektory; Remark:
Procedure Step
Published
08/11/2021 1:43 PM
442 - Disconnect remaining connectors
Instruction
Published
07/22/2021 12:39 PM
446 - 445 - Remove four (4) mounting screws; Remark:444
Procedure Step
Published
08/11/2021 1:43 PM
445 - Remove four (4) mounting screws
Instruction
Published
07/22/2021 12:41 PM
444 - Use a small Phillips (PH1) screwdriver. Retain screws.
Remark
Published
07/22/2021 1:19 PM
450 - 449 - Zvedněte okraj desky PRCB-472, abyste se dostali pod ni; Remark:448
Procedure Step
Published
08/11/2021 1:48 PM
447 - Caution : Do not damage ribbon cable attached to the underside of PRCB-472.
Annotation
Published
10/04/2022 11:11 AM
449 - Raise edge of PRCB-472 board to access underside
Instruction
Published
07/22/2021 12:42 PM
448 - PRM-470 Lifting PRCB-472 circuit board
Remark
Published
11/02/2024 4:30 PM
453 - 452 - Odpojte konektor překryvného tlačítka; Remark:451
Procedure Step
Published
08/11/2021 1:48 PM
452 - Disconnect overlay button connector
Instruction
Published
07/22/2021 12:43 PM
451 - PRM-470 Display circuit board
Remark
Published
11/02/2024 3:35 PM
455 - 454 - Clean overlay connector; Remark:
Procedure Step
Published
08/11/2021 1:49 PM
454 - Clean overlay connector
Instruction
Published
07/22/2021 12:44 PM
458 - 456 - Clean contacts; Remark:457
Procedure Step
Published
08/11/2021 1:49 PM
456 - Clean contacts
Instruction
Published
07/22/2021 12:45 PM
457 - Use electrical contact cleaner or alcohol.
Remark
Published
07/22/2021 12:45 PM
461 - 459 - Připojte a odpojte konektor překryvného tlačítka; Remark:460
Procedure Step
Published
08/11/2021 1:50 PM
459 - Connect and disconnect overlay button connector
Instruction
Published
07/22/2021 12:46 PM
460 - Repeat this multiple times to remove oxidation.
Remark
Published
07/22/2021 12:50 PM
465 - 463 - Znovu připojte konektor překryvného tlačítka; Remark:464
Procedure Step
Published
08/11/2021 1:51 PM
462 - Caution : Correct placement of connectors and wiring is critical to proper operation.
Annotation
Published
09/28/2023 2:13 PM
463 - Reconnect overlay button connector
Instruction
Published
07/22/2021 12:50 PM
464 - PRM-470 - Connecting ribbon cable to overlay button connector
Remark
Published
11/02/2024 3:35 PM
467 - 466 - Reinstall PRCB-472 board; Remark:
Procedure Step
Published
08/11/2021 1:51 PM
466 - Reinstall PRCB-472 board
Instruction
Published
07/22/2021 12:51 PM
470 - 468 - Set PRCB-472 board over mounting posts; Remark:469
Procedure Step
Published
08/11/2021 1:52 PM
468 - Set PRCB-472 board over mounting posts
Instruction
Published
07/22/2021 12:52 PM
469 - Position ribbon cable to avoid obstructing PRCB-472 mounting hole.
Remark
Published
07/22/2021 1:12 PM
473 - 471 - Zašroubujte zpět čtyři (4) montážní šrouby; Remark:472
Procedure Step
Published
08/11/2021 1:53 PM
471 - Reinstall four (4) mounting screws
Instruction
Published
07/22/2021 12:53 PM
472 - Use a small Phillips (PH1) screwdriver.
Remark
Published
07/22/2021 1:13 PM
3394 - 474 - Reseat gamma GHA-472 board; Remark:
Procedure Step
Published
08/11/2021 1:54 PM
474 - Reseat gamma GHA-472 board
Instruction
Published
07/22/2021 12:54 PM
478 - 476 - Remove mounting nut; Remark:477
Procedure Step
Published
08/11/2021 1:54 PM
476 - Remove mounting nut
Instruction
Published
08/07/2021 10:57 AM
477 - PRM-470 - Removing GHA-472 mounting nut
Remark
Published
11/02/2024 2:00 PM
481 - 479 - Vyjměte desku GHA-472; Remark:480
Procedure Step
Published
08/11/2021 1:55 PM
479 - Remove GHA-472 board
Instruction
Published
07/22/2021 12:56 PM
480 - Gently pry up the GHA-472 board from the PRCB-472 board.
Remark
Published
07/22/2021 1:13 PM
484 - 482 - Replace GHA-472 board; Remark:483
Procedure Step
Published
08/11/2021 1:55 PM
482 - Replace GHA-472 board
Instruction
Published
07/22/2021 12:56 PM
483 - Verify connectors are correctly aligned then press down.
Remark
Published
07/22/2021 1:14 PM
490 - 488 - Přimontujte zpět montážní matici desky GHA-472; Remark:489
Procedure Step
Published
08/11/2021 1:56 PM
504 - Caution : Do not overtighten the mounting nut.
Annotation
Published
10/04/2022 11:11 AM
488 - Reinstall GHA-472 board mounting nut
Instruction
Published
07/22/2021 12:57 PM
489 - PRM-470 - Location of GHA-472 mounting nut
Remark
Published
11/02/2024 2:01 PM
3046 - 3044 - Uložte neutronovou desku GHA-472 (pouze u modelu CGN); Remark:3045
Procedure Step
Published
08/11/2021 1:57 PM
3044 - Reseat neutron GHA-472 board (CGN model only)
Instruction
Published
07/22/2021 12:58 PM
3045 - Repeat the reseat process for the GHA-472 board.
Remark
Published
07/22/2021 1:15 PM
492 - 491 - Additional checks; Remark:
Procedure Step
Published
08/11/2021 2:05 PM
491 - Additional checks
Instruction
Published
07/22/2021 12:59 PM
495 - 493 - Verify PMT Select X1 jumper location; Remark:494
Procedure Step
Published
08/11/2021 2:05 PM
493 - Verify PMT Select X1 jumper location
Instruction
Published
07/22/2021 1:00 PM
494 - Jumper is located on the GHA-472 board. It is usually connected to contact 19...
Remark
Published
07/22/2021 1:16 PM
299 - 298 - Locate RS-232 (Spare); Remark:287
Procedure Step
Published
08/11/2021 2:06 PM
298 - Locate RS-232 (Spare)
Instruction
Published
07/20/2021 3:42 PM
287 - RS-232 spare pins are located on main circuit board (PRCB-472).
Remark
Published
10/06/2022 10:15 AM
297 - 296 - Odstraňte kolíky RS-232; Remark:288
Procedure Step
Published
08/11/2021 2:10 PM
296 - Remove RS-232 pins
Instruction
Published
07/22/2021 1:00 PM
288 - Use pliers to bend pins back and forth until they break. Dispose of pins. Thi...
Remark
Published
07/21/2021 12:18 PM
497 - 496 - Zkontrolujte umístění baterie; Remark:274
Procedure Step
Published
08/11/2021 2:11 PM
496 - Verify battery position
Instruction
Published
07/22/2021 1:01 PM
274 - To minimize damage to wiring, insert battery pack with wiring side down. Push...
Remark
Published
07/21/2021 12:16 PM
303 - 302 - Reassemble instrument; Remark:
Procedure Step
Published
10/07/2022 1:49 PM
302 - Reassemble instrument
Instruction
Published
06/16/2021 11:28 PM
500 - 498 - Reconnect all connectors except battery; Remark:499
Procedure Step
Published
08/11/2021 2:02 PM
498 - Reconnect all connectors except battery
Instruction
Published
07/22/2021 1:02 PM
499 - Do not connect location 1.
Remark
Published
07/22/2021 1:17 PM
503 - 305 - Opět zapojte baterii; Remark:502
Procedure Step
Published
08/11/2021 2:03 PM
305 - Reconnect battery
Instruction
Published
07/29/2021 3:48 PM
502 - PRM-470 - Reconnect battery at position 1
Remark
Published
11/02/2024 3:36 PM
308 - 307 - Vraťte přední kryt na místo; Remark:
Procedure Step
Published
08/11/2021 2:03 PM
304 - Caution : Ensure all wiring is inside the instrument while replacing cover.
Annotation
Published
10/04/2022 11:10 AM
307 - Replace front cover
Instruction
Published
07/20/2021 3:57 PM
310 - 309 - Utáhněte čtyři (4) šrouby v krytu; Remark:417
Procedure Step
Published
08/11/2021 2:04 PM
569 - Caution : Do not overtighten screws.
Annotation
Published
06/16/2021 2:31 PM
309 - Tighten four (4) cover screws
Instruction
Published
07/22/2021 1:02 PM
417 - Use a medium Phillips (PH2) screwdriver.
Remark
Published
07/22/2021 1:18 PM
312 - 311 - Verify instrument charges successfully; Remark:
Procedure Step
Published
07/20/2021 10:53 AM
311 - Verify instrument charges successfully
Instruction
Published
07/20/2021 10:44 AM
316 - 315 - Připojte nabíječku; Remark:289
Procedure Step
Published
07/29/2021 3:07 PM
315 - Connect charger
Instruction
Published
07/20/2021 10:45 AM
289 - Plug charger into instrument and AC power outlet
Remark
Published
07/20/2021 10:48 AM
318 - 317 - Sledujte stav nabíječky; Remark:290
Procedure Step
Published
07/29/2021 3:07 PM
317 - Observe charger status
Instruction
Published
07/20/2021 10:45 AM
290 - This charger has a blinking yellow light when charging.
Remark
Published
07/20/2021 10:49 AM
291 - This charger has a solid light when it is charging.
Remark
Published
07/21/2021 12:21 PM
253 - 242 - Document and report any unresolved problems; Remark:
Procedure Step
Published
06/22/2021 10:23 AM
242 - Document and report any unresolved problems
Instruction
Published
04/21/2025 11:45 AM
Corrective Maintenance Procedure
Document Type
Published
03/02/2020 3:32 PM
20 minutes
Duration
Published
05/18/2020 5:44 PM
As Needed
Frequency
Published
04/01/2020 11:36 AM
Note
Annotation Type
Published
03/02/2020 3:25 PM
Caution
Annotation Type
Published
03/02/2020 3:24 PM
Technician 2
Skill Level
Published
04/09/2020 1:17 AM
Medium Phillips (PH2) screwdriver
Tools
Published
04/24/2020 4:40 PM
Small Phillips (PH1) screwdriver
Tools
Published
05/14/2020 2:48 PM
5-mm (1/4 inch) nut driver or socket
Tools
Published
05/14/2020 3:21 PM
Needle nose pliers
Tools
Published
05/06/2020 4:10 PM
PRM470_Remove_Screws_Top_Case
Image
Published
05/08/2020 6:05 PM
PRM-470_di_CGN_open_00536
Image
Published
02/19/2023 11:26 AM
Battery_connection_is_labeled_1
Image
Published
02/19/2023 10:46 AM
PRM-470_Disconnect_battery
Image
Published
05/09/2020 8:40 PM
PRM-470 Remove four mounting screws on PRCB-472
Image
Published
05/11/2020 7:57 PM
PRM-470_Raise_edge_of _PRCB-472_board_gamma_on
Image
Published
05/20/2020 2:04 PM
PRM-470 Remove ribbon cable from PRCB-472 LCD Functional
Image
Published
05/20/2020 10:03 AM
PRM-470 Overlay connection contacts
Image
Published
05/12/2020 12:11 PM
PRM-470 cleaning overlay connection cable
Image
Published
05/20/2020 10:06 AM
PRM-470 - Connecting ribbon cable to overlay button connector
Image
Published
05/12/2020 12:56 PM
PRM-470_Set_PRCB-472_board_gamma_on
Image
Published
05/20/2020 2:13 PM
Remove metal brackets
Image
Published
09/08/2023 2:50 PM
Remove metal brackets 2
Image
Published
09/08/2023 2:51 PM
PRM-470 - GHA-472 mounting nut location
Image
Published
02/19/2023 11:37 AM
PRM-470 - GHA-472 mounting nut removal
Image
Published
05/12/2020 1:29 PM
PRM-470 - Removing GHA-472 board
Image
Published
05/12/2020 1:40 PM
PRM-470 - Re-seating GHA-472 board
Image
Published
05/12/2020 1:47 PM
PRM-470 - Re-seating the GHA-472 board
Image
Published
05/12/2020 1:53 PM
PRM-470 - GHA-472 mounting nut location
Image
Published
05/12/2020 2:00 PM
PRM-470 - Jumper PMT Select X1 location
Image
Published
05/12/2020 2:50 PM
PRM-470 Locate RS-232 spare pins
Image
Published
05/10/2020 8:07 PM
PRM-470 - RS-232 spare pins location
Image
Published
05/12/2020 2:59 PM
PRM-470 - Removing spare RS-232 pins
Image
Published
05/10/2020 8:10 PM
PRM-470_Insert_new_battery_pack
Image
Published
05/10/2020 7:58 PM
PRM470_Battery_connection_is_labeled_1
Image
Published
02/19/2023 10:40 AM
PRM-470_Reconnect_battery
Image
Published
05/10/2020 8:16 PM
PRM-470_Tighten_4_cover_screws
Image
Published
05/10/2020 8:22 PM
PRM-470 Port for Charging Cord Red Arrow
Image
Published
05/09/2020 1:49 PM
PRM-470 Charger_New Wall Plug Red Arrow
Image
Published
05/09/2020 1:47 PM
PRM-470 Charger_New Yellow LED On Red Circle
Image
Published
05/09/2020 1:43 PM
PRM-470 Charger_Old Yellow LED Off Red Circle
Image
Published
05/09/2020 1:45 PM

PRM-470 Battery Replacement

Last Updated: 05/12/2025 1:54 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Rapiscan PRM-470 CG
Device
Published
10/28/2024 3:40 PM
Rapiscan PRM-470 CGN
Device
Published
10/28/2024 3:33 PM
247 - 257 - Prepare instrument; Remark:
Procedure Step
Published
04/11/2025 9:08 PM
257 - Prepare instrument
Instruction
Published
04/11/2025 9:07 PM
607 - 205 - Disconnect charger; Remark:
Procedure Step
Published
07/23/2021 2:42 PM
205 - Disconnect charger
Instruction
Published
07/23/2021 2:42 PM
260 - 313 - Power off instrument; Remark:
Procedure Step
Published
07/23/2021 2:43 PM
313 - Power off instrument
Instruction
Published
07/23/2021 2:41 PM
261 - 65 - Uvolněte čtyři (4) šrouby v krytu; Remark:264
Procedure Step
Published
08/12/2021 7:25 AM
65 - Loosen four (4) cover screws
Instruction
Published
07/22/2021 12:38 PM
264 - Use a medium Phillips (PH2) screwdriver. Screws do not need to be completely ...
Remark
Published
07/20/2021 3:59 PM
263 - 262 - Odstraňte kryt přístroje; Remark:413
Procedure Step
Published
08/11/2021 1:41 PM
2771 - Note : There are high-voltage detector circuit boards inside the instrument; however...
Annotation
Published
10/04/2022 11:06 AM
262 - Remove instrument cover
Instruction
Published
07/20/2021 3:35 PM
413 - PRM-470 Remove Instrument Cover
Remark
Published
11/01/2024 8:32 PM
267 - 266 - Vyhledejte přípojku baterie; Remark:272
Procedure Step
Published
08/11/2021 1:42 PM
3033 - Note : PRM-470 CGN models have an additional board and connectors not shown in remar...
Annotation
Published
10/04/2022 11:07 AM
266 - Locate battery connection
Instruction
Published
07/20/2021 3:36 PM
272 - Battery connection is labeled 1.
Remark
Published
07/21/2021 12:11 PM
271 - 270 - Odpojte baterii; Remark:414
Procedure Step
Published
08/11/2021 1:42 PM
1345 - Note : It is good practice to ensure all cables and connectors are labeled prior to ...
Annotation
Published
10/04/2022 11:08 AM
270 - Disconnect battery
Instruction
Published
07/20/2021 3:37 PM
414 - PRM-470_Disconnect_battery
Remark
Published
11/02/2024 1:21 PM
278 - 277 - Replace battery pack; Remark:
Procedure Step
Published
08/26/2021 3:32 PM
277 - Replace battery pack
Instruction
Published
07/20/2021 3:38 PM
280 - 279 - Remove battery pack; Remark:268
Procedure Step
Published
08/26/2021 3:32 PM
279 - Remove battery pack
Instruction
Published
04/05/2025 1:26 PM
268 - Battery pack is held in place with a Velcro strip adhered to bottom of instru...
Remark
Published
07/29/2021 3:55 PM
282 - 281 - Odeberte pásku se suchým zipem; Remark:415
Procedure Step
Published
08/26/2021 3:32 PM
281 - Remove Velcro strip
Instruction
Published
07/20/2021 3:40 PM
415 - PRM-470_Remove_Velcro_strip
Remark
Published
11/01/2024 8:37 PM
284 - 283 - Upevněte pásku se suchým zipem přes nový akumulátor; Remark:273
Procedure Step
Published
08/26/2021 3:33 PM
283 - Adhere Velcro strip to new battery pack
Instruction
Published
07/20/2021 3:41 PM
273 - The Velcro is applied to the wiring side of the battery pack
Remark
Published
07/21/2021 12:15 PM
286 - 285 - Vložte nový akumulátor; Remark:274
Procedure Step
Published
08/26/2021 3:33 PM
285 - Insert new battery pack
Instruction
Published
07/20/2021 3:41 PM
274 - To minimize damage to wiring, insert battery pack with wiring side down. Push...
Remark
Published
07/21/2021 12:16 PM
301 - 300 - Remove pins; Remark:
Procedure Step
Published
08/26/2021 3:34 PM
300 - Remove pins
Instruction
Published
07/20/2021 3:43 PM
299 - 298 - Locate RS-232 (Spare); Remark:287
Procedure Step
Published
08/11/2021 2:06 PM
298 - Locate RS-232 (Spare)
Instruction
Published
07/20/2021 3:42 PM
287 - RS-232 spare pins are located on main circuit board (PRCB-472).
Remark
Published
10/06/2022 10:15 AM
297 - 296 - Odstraňte kolíky RS-232; Remark:288
Procedure Step
Published
08/11/2021 2:10 PM
296 - Remove RS-232 pins
Instruction
Published
07/22/2021 1:00 PM
288 - Use pliers to bend pins back and forth until they break. Dispose of pins. Thi...
Remark
Published
07/21/2021 12:18 PM
303 - 302 - Reassemble instrument; Remark:
Procedure Step
Published
10/07/2022 1:49 PM
302 - Reassemble instrument
Instruction
Published
06/16/2021 11:28 PM
306 - 305 - Reconnect battery; Remark:416
Procedure Step
Published
08/11/2021 3:11 PM
305 - Reconnect battery
Instruction
Published
07/29/2021 3:48 PM
416 - PRM-470 Battery Replacement - Reconnect battery
Remark
Published
11/02/2024 2:02 PM
308 - 307 - Vraťte přední kryt na místo; Remark:
Procedure Step
Published
08/11/2021 2:03 PM
304 - Caution : Ensure all wiring is inside the instrument while replacing cover.
Annotation
Published
10/04/2022 11:10 AM
307 - Replace front cover
Instruction
Published
07/20/2021 3:57 PM
310 - 309 - Utáhněte čtyři (4) šrouby v krytu; Remark:417
Procedure Step
Published
08/11/2021 2:04 PM
569 - Caution : Do not overtighten screws.
Annotation
Published
06/16/2021 2:31 PM
309 - Tighten four (4) cover screws
Instruction
Published
07/22/2021 1:02 PM
417 - Use a medium Phillips (PH2) screwdriver.
Remark
Published
07/22/2021 1:18 PM
312 - 311 - Verify instrument charges successfully; Remark:
Procedure Step
Published
07/20/2021 10:53 AM
311 - Verify instrument charges successfully
Instruction
Published
07/20/2021 10:44 AM
314 - 313 - Power off instrument; Remark:
Procedure Step
Published
08/12/2021 6:54 AM
316 - 315 - Připojte nabíječku; Remark:289
Procedure Step
Published
07/29/2021 3:07 PM
315 - Connect charger
Instruction
Published
07/20/2021 10:45 AM
289 - Plug charger into instrument and AC power outlet
Remark
Published
07/20/2021 10:48 AM
318 - 317 - Sledujte stav nabíječky; Remark:290
Procedure Step
Published
07/29/2021 3:07 PM
317 - Observe charger status
Instruction
Published
07/20/2021 10:45 AM
290 - This charger has a blinking yellow light when charging.
Remark
Published
07/20/2021 10:49 AM
291 - This charger has a solid light when it is charging.
Remark
Published
07/21/2021 12:21 PM
320 - 319 - Perform operational test; Remark:347
Procedure Step
Published
08/12/2021 7:12 AM
319 - Perform operational test
Instruction
Published
06/10/2021 8:31 PM
347 - Perform DET-HHD-RAP-RM01 PRM-470 Operational Test.
Remark
Published
07/21/2021 12:22 PM
322 - 321 - Document maintenance actions; Remark:
Procedure Step
Published
06/17/2021 9:49 AM
321 - Document maintenance actions
Instruction
Published
04/21/2025 11:19 AM
2869 - 2585 - Document maintenance performed; Remark:2866
Procedure Step
Published
06/18/2021 5:58 PM
2585 - Document maintenance performed
Instruction
Published
07/09/2021 12:15 PM
2866 - Record observations, times, and results for the maintenance report.
Remark
Published
04/21/2025 11:39 AM
4706 - 4705 - Submit report; Remark:4864
Procedure Step
Published
06/29/2022 9:50 AM
4705 - Submit report
Instruction
Published
06/29/2022 9:50 AM
4864 - As specified by management or contractual obligations.
Remark
Published
07/28/2022 1:36 PM
Corrective Maintenance Procedure
Document Type
Published
03/02/2020 3:32 PM
15 minutes
Duration
Published
04/01/2020 11:35 AM
As Needed
Frequency
Published
04/01/2020 11:36 AM
Note
Annotation Type
Published
03/02/2020 3:25 PM
Caution
Annotation Type
Published
03/02/2020 3:24 PM
Technician 1
Skill Level
Published
05/14/2020 2:56 PM
Medium Phillips (PH2) screwdriver
Tools
Published
04/24/2020 4:40 PM
Needle nose pliers
Tools
Published
05/06/2020 4:10 PM
PRM470_Remove_Screws_Top_Case
Image
Published
05/08/2020 6:05 PM
PRM-470_di_CGN_open_00536
Image
Published
02/19/2023 11:26 AM
Battery_connection_is_labeled_1
Image
Published
02/19/2023 10:46 AM
PRM-470_Disconnect_battery
Image
Published
05/09/2020 8:40 PM
PMR-470_Battery_pack-removals
Image
Published
05/09/2020 8:46 PM
PRM-470_Remove_Velcro_strip
Image
Published
05/10/2020 7:38 PM
PRM470_The_Velcro_is_applied_to_the_wiring_side
Image
Published
05/10/2020 7:54 PM
PRM-470_Insert_new_battery_pack
Image
Published
05/10/2020 7:58 PM
PRM-470 Locate RS-232 spare pins
Image
Published
05/10/2020 8:07 PM
PRM-470 - RS-232 spare pins location
Image
Published
05/12/2020 2:59 PM
PRM-470 - Removing spare RS-232 pins
Image
Published
05/10/2020 8:10 PM
PRM-470_Reconnect_battery
Image
Published
05/10/2020 8:16 PM
PRM-470_Tighten_4_cover_screws
Image
Published
05/10/2020 8:22 PM
PRM-470 Port for Charging Cord Red Arrow
Image
Published
05/09/2020 1:49 PM
PRM-470 Charger_New Wall Plug Red Arrow
Image
Published
05/09/2020 1:47 PM
PRM-470 Charger_New Yellow LED On Red Circle
Image
Published
05/09/2020 1:43 PM
PRM-470 Charger_Old Yellow LED Off Red Circle
Image
Published
05/09/2020 1:45 PM