Skip to main content
Home
FRONTLINE Maintenance Tool
  • Add Content
  • Structures
    • Content Management
  • Content Views
  • Exports
  • Management

Breadcrumb

  1. Home

9969 - 9884 - Swap signal cables at SCA-774 board - Decision, Notes: 9965

9873 - Note : Be sure to return all cables and connectors to their correct positions at the...

Type
Note

Be sure to return all cables and connectors to their correct positions at the end of troubleshooting and repair effort

9884 - Swap signal cables at SCA-774 board

Swap signal cables at SCA-774 board
Yes
Go to
9967 - 9964 - Swap cables at bottom of PMFX Box - Decision, Notes: 9885
No
Go to
9958 - 9869 - Swap SC-770 controller connectors - Decision, Notes: 7236
Note
9965 - Navigate to SHOW COUNTS on the SC-770  
9968 - While watching SHOW COUNTS, switch the BNC connectors for neutron CH3 and CH4...
9888 - Did the fault indication move from the original channel to the other?