The following table lists all the components that make up the document.

Title Type Status Last Updated
Rapiscan PM-700 Pedestrian Monitor
Device
Published
06/20/2024 11:38 AM
1402 - 7927 - Establish Initial Conditions; Remark:
Procedure Step
Published
09/30/2022 1:47 PM
7927 - Establish Initial Conditions
Instruction
Published
07/12/2023 12:23 AM
8972 - 7231 - Close lane; Remark:7415
Procedure Step
Published
09/25/2023 10:51 PM
7231 - Close lane
Instruction
Published
04/18/2023 1:00 PM
7415 - Re-route pedestrian traffic.
Remark
Published
06/02/2023 1:08 PM
7269 - 7232 - Open RPM door; Remark:7234
Procedure Step
Published
04/27/2023 7:02 PM
7232 - Open RPM door
Instruction
Published
04/18/2023 1:02 PM
7234 - Open all doors needed to access components.
Remark
Published
04/19/2025 7:48 PM
7454 - 7290 - Disable tamper switches; Remark:7416
Procedure Step
Published
06/02/2023 5:25 PM
7290 - Disable tamper switches
Instruction
Published
05/01/2023 8:14 AM
7416 - Use a magnet to disable tamper switches for all open doors. Use adhesive tape...
Remark
Published
06/02/2023 1:18 PM
7270 - 7235 - Power off RPM; Remark:7236
Procedure Step
Published
09/01/2023 7:57 PM
7235 - Power off RPM
Instruction
Published
04/24/2023 12:30 PM
7236 - Move LD-260 switch to OFF position. The PWR ON
Remark
Published
04/27/2023 4:25 PM
7479 - 7417 - Prepare New Occupancy Sensor; Remark:
Procedure Step
Published
06/02/2023 6:13 PM
7417 - Prepare New Occupancy Sensor
Instruction
Published
06/02/2023 1:39 PM
7456 - 7418 - Remove cover from new occupancy sensor; Remark:7419
Procedure Step
Published
06/02/2023 5:27 PM
7418 - Remove cover from new occupancy sensor
Instruction
Published
06/02/2023 1:43 PM
7419 - Use a slotted screwdriver to pry the cover off from the side.
Remark
Published
04/13/2025 5:44 PM
7457 - 7420 - Verify narrow field radar antenna is installed; Remark:7421
Procedure Step
Published
04/13/2025 6:18 PM
7420 - Verify narrow field radar antenna is installed
Instruction
Published
04/13/2025 5:44 PM
7421 - The IXIO-DT1 should come with the narrow field antenna installed.
Remark
Published
06/02/2023 2:14 PM
8901 - If needed, the antenna can be changed. Remove cover. Install narrow field ant...
Remark
Published
09/25/2023 9:51 PM
8889 - 8888 - Prepare Mounting Holes; Remark:
Procedure Step
Published
09/25/2023 4:55 PM
8888 - Prepare Mounting Holes
Instruction
Published
09/25/2023 4:54 PM
8884 - 8883 - Mark mounting hole height; Remark:8882
Procedure Step
Published
09/25/2023 4:58 PM
8883 - Mark mounting hole height
Instruction
Published
09/25/2023 4:56 PM
8882 - Use erasable marker or pencil to draw a level horizontal line. Mounting hole ...
Remark
Published
09/25/2023 4:58 PM
8886 - 8879 - Mark centerline of pedestrian monitor door; Remark:8878
Procedure Step
Published
09/25/2023 5:01 PM
8879 - Mark centerline of pedestrian monitor door
Instruction
Published
09/25/2023 5:00 PM
8878 - Use erasable marker or pencil to draw a vertical line.
Remark
Published
09/25/2023 5:01 PM
8885 - 8881 - Attach mounting template; Remark:8880
Procedure Step
Published
09/25/2023 4:59 PM
8881 - Attach mounting template
Instruction
Published
09/25/2023 4:58 PM
8880 - Template provided with the IXIO-DT1 has a self-adhesive backing. Template may...
Remark
Published
09/25/2023 4:59 PM
8887 - 8877 - Mark location of 3.2-mm (1/8-inch) mounting holes; Remark:8876
Procedure Step
Published
09/25/2023 5:03 PM
8904 - Caution : Ensure placement of mounting holes will not interfere with internal wiring in...
Annotation
Published
09/25/2023 9:57 PM
8877 - Mark location of 3.2-mm (1/8-inch) mounting holes
Instruction
Published
09/25/2023 5:01 PM
8876 - If available, use a center punch and hammer to create a dimple at each mounti...
Remark
Published
09/25/2023 5:01 PM
8905 - 8903 - Mark location of 8-mm (5/16-inch) hole for wire passage; Remark:8902
Procedure Step
Published
09/25/2023 9:58 PM
8903 - Mark location of 8-mm (5/16-inch) hole for wire passage
Instruction
Published
09/25/2023 9:58 PM
8902 - If available, use a center punch and hammer to create a dimple at center of w...
Remark
Published
09/25/2023 9:58 PM
8946 - 8945 - Drill Installation Holes; Remark:
Procedure Step
Published
09/25/2023 10:01 PM
8945 - Drill Installation Holes
Instruction
Published
09/25/2023 10:01 PM
8939 - 8938 - Hold or block the door in an open position; Remark:
Procedure Step
Published
09/25/2023 10:01 PM
8938 - Hold or block the door in an open position
Instruction
Published
09/25/2023 10:01 PM
8940 - 8935 - Drill two (2) mounting holes; Remark:8934
Procedure Step
Published
09/25/2023 10:02 PM
8936 - Warning : Wear protective gloves and eyewear when drilling into cabinet door.
Annotation
Published
09/25/2023 10:05 PM
8937 - Caution : Do not damage interior of RPM when drilling holes.
Annotation
Published
09/25/2023 10:05 PM
8935 - Drill two (2) mounting holes
Instruction
Published
09/25/2023 10:02 PM
8934 - Use a 3.2-mm (1/8-inch) drill bit.
Remark
Published
09/25/2023 10:02 PM
8941 - 8933 - Drill wire passage hole; Remark:8932
Procedure Step
Published
09/25/2023 10:03 PM
8933 - Drill wire passage hole
Instruction
Published
09/25/2023 10:03 PM
8932 - Use an 8-mm (5/16-inch) drill bit.
Remark
Published
09/25/2023 10:03 PM
8942 - 8931 - Clean newly drilled holes; Remark:8930
Procedure Step
Published
09/25/2023 10:04 PM
8931 - Clean newly drilled holes
Instruction
Published
09/25/2023 10:04 PM
8930 - Use the deburring tool
Remark
Published
09/25/2023 10:04 PM
8943 - 8929 - Partially insert two (2) screws into mounting holes; Remark:8928
Procedure Step
Published
09/25/2023 10:06 PM
8929 - Partially insert two (2) screws into mounting holes
Instruction
Published
09/25/2023 10:06 PM
8928 - Mounting screws are included in the IXIO-DT-1 kit. Do not fully tighten screw...
Remark
Published
09/25/2023 10:06 PM
8944 - 8926 - Insert rubber grommet in wire passage hole; Remark:8925
Procedure Step
Published
09/25/2023 10:08 PM
8927 - Note : Protecting wires with a rubber grommet is critical to preventing damage to wi...
Annotation
Published
09/25/2023 10:08 PM
8926 - Insert rubber grommet in wire passage hole
Instruction
Published
09/25/2023 10:07 PM
8925 - rubber grommet
Remark
Published
09/25/2023 10:08 PM
8924 - 8923 - Install IXIO-DT1 Sensor; Remark:
Procedure Step
Published
09/25/2023 10:09 PM
8923 - Install IXIO-DT1 Sensor
Instruction
Published
09/25/2023 10:09 PM
8918 - 8917 - Feed wiring connector through grommet; Remark:8915
Procedure Step
Published
09/25/2023 10:13 PM
8917 - Feed wiring connector through grommet
Instruction
Published
09/25/2023 10:11 PM
8915 - The wiring assembly is included in the IXIO-DT1 kit. Feed loose end of wiring...
Remark
Published
09/25/2023 10:11 PM
8916 - Leave approximately 15 cm (6 in) of wire remaining outside of cabinet.
Remark
Published
09/25/2023 10:13 PM
8919 - 8914 - Mount new sensor; Remark:8912
Procedure Step
Published
09/25/2023 10:15 PM
8914 - Mount new sensor
Instruction
Published
09/25/2023 10:13 PM
8912 - First, slide left side onto mounting screw.
Remark
Published
09/25/2023 10:14 PM
8913 - Then, place right side over mounting screw and push down.
Remark
Published
09/25/2023 10:15 PM
8920 - 8911 - Tighten two (2) mounting screws; Remark:8910
Procedure Step
Published
09/25/2023 10:16 PM
8911 - Tighten two (2) mounting screws
Instruction
Published
09/25/2023 10:15 PM
8910 - Use medium Phillips (PH2) screwdriver. Take care not to overtighten.
Remark
Published
09/25/2023 10:16 PM
8921 - 8909 - Route wiring through clamp and connect; Remark:8908
Procedure Step
Published
09/25/2023 10:18 PM
8909 - Route wiring through clamp and connect
Instruction
Published
09/25/2023 10:16 PM
8908 - route wiring through clamp and connect
Remark
Published
09/25/2023 10:18 PM
8922 - 8907 - Adjust angle of the radar antenna; Remark:8906
Procedure Step
Published
09/25/2023 10:20 PM
8907 - Adjust angle of the radar antenna
Instruction
Published
09/25/2023 10:18 PM
8906 - The angle is adjusted by manually rotating the antenna up or down. The defaul...
Remark
Published
09/25/2023 10:20 PM
8970 - 8969 - Connect Wiring to RPM; Remark:
Procedure Step
Published
09/25/2023 10:23 PM
8969 - Connect Wiring to RPM
Instruction
Published
09/25/2023 10:22 PM
8963 - 8962 - Disconnect existing SPY-2 wiring; Remark:8961
Procedure Step
Published
09/25/2023 10:25 PM
7351 - Note : It is good practice to verify all cables and connectors are labeled prior to ...
Annotation
Published
05/03/2023 11:25 AM
8962 - Disconnect existing SPY-2 wiring
Instruction
Published
09/25/2023 10:24 PM
8961 - Do not remove existing occupancy sensor from door panel. Disconnect SPY-2 wir...
Remark
Published
09/25/2023 10:24 PM
8964 - 8960 - Route new cable to TB2; Remark:8959
Procedure Step
Published
09/25/2023 10:26 PM
8960 - Route new cable to TB2
Instruction
Published
09/25/2023 10:25 PM
8959 - New IXIO-DT1 cable should be routed along existing SPY-2 cable. Cable ties ma...
Remark
Published
09/25/2023 10:26 PM
8965 - 8958 - Connect red wire to TB2, Pin 16; Remark:8956
Procedure Step
Published
09/25/2023 10:30 PM
7263 - Caution : Correct placement of connectors and wiring is critical to proper operation.
Annotation
Published
04/24/2023 2:32 PM
8958 - Connect red wire to TB2, Pin 16
Instruction
Published
09/25/2023 10:27 PM
8956 - Red is power (+12 VDC) wire.
Remark
Published
09/25/2023 10:29 PM
8957 - For models with older terminal blocks, it may be necessary to use a fork conn...
Remark
Published
09/25/2023 10:30 PM
8966 - 8955 - Connect both black and white wires to TB2, Pin 15; Remark:8954
Procedure Step
Published
09/25/2023 10:32 PM
8955 - Connect both black and white wires to TB2, Pin 15
Instruction
Published
09/25/2023 10:31 PM
8954 - Black is the ground wire. White is the common wire
Remark
Published
09/25/2023 10:32 PM
8967 - 8953 - Connect green wire to TB2, Pin 6; Remark:8952
Procedure Step
Published
09/25/2023 10:34 PM
8953 - Connect green wire to TB2, Pin 6
Instruction
Published
09/25/2023 10:33 PM
8952 - Green is the occupancy signal to the SCA-775 module.
Remark
Published
09/25/2023 10:34 PM
8968 - 8951 - Apply sealant if needed; Remark:8950
Procedure Step
Published
09/25/2023 10:35 PM
8951 - Apply sealant if needed
Instruction
Published
09/25/2023 10:34 PM
8950 - Access wire penetration hole from back of the RPM door.
Remark
Published
09/25/2023 10:35 PM
7279 - 7249 - Return equipment to normal operating condition; Remark:
Procedure Step
Published
04/27/2023 4:13 PM
7249 - Return equipment to normal operating condition
Instruction
Published
04/08/2025 3:22 PM
8949 - 8948 - Hold door open; Remark:8947
Procedure Step
Published
09/25/2023 10:37 PM
8948 - Hold door open
Instruction
Published
09/25/2023 10:37 PM
8947 - Do not move door. Door must remain stationary to prevent occupancy.
Remark
Published
09/25/2023 10:37 PM
7280 - 7250 - Power on RPM; Remark:7251
Procedure Step
Published
04/27/2023 4:14 PM
7250 - Power on RPM
Instruction
Published
05/01/2023 8:31 AM
7251 - Move LD-260 switch to ON position. The LED PWR ON
Remark
Published
05/10/2023 3:14 PM
7468 - 7304 - Confirm RPM has restarted correctly; Remark:7487
Procedure Step
Published
06/02/2023 5:36 PM
7304 - Confirm RPM has restarted correctly
Instruction
Published
05/01/2023 8:31 AM
7487 - The SC-770 controller will display "OK" following Power On Self-Test (POST) a...
Remark
Published
06/02/2023 10:35 PM
7389 - 7254 - Confirm network connection; Remark:7255
Procedure Step
Published
05/04/2023 4:33 PM
7254 - Confirm network connection
Instruction
Published
04/27/2023 2:22 PM
7255 - Contact operators to confirm communications have been reestablished between RPM ...
Remark
Published
05/10/2023 3:15 PM
7470 - 7442 - Generate occupancy; Remark:7443
Procedure Step
Published
06/02/2023 5:37 PM
7442 - Generate occupancy
Instruction
Published
06/02/2023 4:19 PM
7443 - Create motion in front of occupancy sensor. While holding the door open and s...
Remark
Published
06/02/2023 4:21 PM
7471 - 7444 - Verify occupancy sensor functionality; Remark:7445
Procedure Step
Published
06/02/2023 5:38 PM
7444 - Verify occupancy sensor functionality
Instruction
Published
06/02/2023 4:32 PM
7445 - IXIO-DT1 green sensor light will illuminate.
Remark
Published
06/02/2023 4:35 PM
8973 - Left latch on the LCD screen will indicate a “closed” circuit.
Remark
Published
09/25/2023 11:05 PM
8974 - SC-770 status will read “OCCUPIED”.
Remark
Published
09/25/2023 11:06 PM
7472 - 7446 - Install sensor cover; Remark:7447
Procedure Step
Published
06/02/2023 5:38 PM
7446 - Install sensor cover
Instruction
Published
06/02/2023 4:37 PM
7447 - The cover should snap into place.
Remark
Published
06/02/2023 4:38 PM
7473 - 7448 - If needed, apply sealant; Remark:7449
Procedure Step
Published
06/02/2023 5:39 PM
7448 - If needed, apply sealant
Instruction
Published
06/02/2023 4:39 PM
7449 - If used outdoors, sealant should be applied to top and sides of cover. Do not...
Remark
Published
06/02/2023 4:41 PM
7474 - 7310 - Enable tamper switches; Remark:7451
Procedure Step
Published
06/02/2023 5:41 PM
7310 - Enable tamper switches
Instruction
Published
05/01/2023 8:36 AM
7451 - Remove magnets and/or adhesive tape from door tamper switches.
Remark
Published
04/13/2025 5:46 PM
7283 - 7256 - Close and lock all RPM doors; Remark:
Procedure Step
Published
09/01/2023 11:45 PM
7256 - Close and lock all RPM doors
Instruction
Published
04/27/2023 2:21 PM
7842 - 7820 - Inform system operators upon completion of maintenance action; Remark:
Procedure Step
Published
07/07/2023 11:15 PM
7820 - Inform system operators upon completion of maintenance action
Instruction
Published
07/07/2023 10:02 PM
322 - 321 - Document maintenance actions; Remark:
Procedure Step
Published
06/17/2021 9:49 AM
321 - Document maintenance actions
Instruction
Published
04/21/2025 11:19 AM
2869 - 2585 - Document maintenance performed; Remark:2866
Procedure Step
Published
06/18/2021 5:58 PM
2585 - Document maintenance performed
Instruction
Published
07/09/2021 12:15 PM
2866 - Record observations, times, and results for the maintenance report.
Remark
Published
04/21/2025 11:39 AM
4706 - 4705 - Submit report; Remark:4864
Procedure Step
Published
06/29/2022 9:50 AM
4705 - Submit report
Instruction
Published
06/29/2022 9:50 AM
4864 - As specified by management or contractual obligations.
Remark
Published
07/28/2022 1:36 PM
Corrective Maintenance Procedure
Document Type
Published
03/02/2020 3:32 PM
minutes
Duration
Published
05/26/2022 11:41 AM
Upon failure of the Visonic SPY-2 infrared curtain occupancy sensor
Frequency
Published
09/25/2023 3:49 PM
Caution
Annotation Type
Published
03/02/2020 3:24 PM
Warning
Annotation Type
Published
03/02/2020 3:25 PM
Note
Annotation Type
Published
03/02/2020 3:25 PM
Technician 2
Skill Level
Published
04/09/2020 1:17 AM
Keys to access RPM
Replacement Parts
Published
04/27/2023 6:56 PM
Magnets and adhesive tape to disable door tamper switches
Replacement Parts
Published
06/02/2023 10:08 PM
Medium Phillips (PH2) screwdriver
Tools
Published
04/24/2020 4:40 PM
Cordless drill
Tools
Published
09/25/2023 4:19 PM
3.2-mm (1/8-inch) drill bit (for metal)
Tools
Published
09/25/2023 4:19 PM
8-mm (5/16-inch) drill bit (for metal)
Tools
Published
09/25/2023 4:19 PM
Deburring tool
Tools
Published
09/25/2023 4:20 PM
safety glasses
Replacement Parts
Published
07/02/2023 4:48 PM
Gloves (heavy duty)
Tools
Published
09/25/2023 4:20 PM
Wire stripper
Tools
Published
09/25/2023 4:20 PM
Wire crimping tool
Tools
Published
09/25/2023 4:20 PM
Orange/yellow safety vest
Replacement Parts
Published
04/27/2023 6:56 PM
Safety shoes
Replacement Parts
Published
04/27/2023 6:56 PM
Protective headwear: glasses, hard hat
Replacement Parts
Published
05/10/2023 3:31 PM
Orange traffic cones
Replacement Parts
Published
04/27/2023 6:56 PM
Disable tamper switch
Image
Published
09/07/2023 8:22 PM
Disable Tamper Switch
Image
Published
06/02/2023 2:28 PM
LD-260 Disconnect Switch Power Off
Image
Published
04/24/2023 12:49 PM
Remove Occupancy Sensor Cover
Image
Published
06/02/2023 2:38 PM
The IXIO-DT1 should come with the narrow field antenna installed
Image
Published
09/25/2023 8:35 PM
Verify narrow field radar antenna is installed
Image
Published
09/25/2023 8:38 PM
Verify narrow field radar antenna is installed 2
Image
Published
09/25/2023 8:39 PM
Mark mounting hole height
Image
Published
09/25/2023 8:40 PM
Mark centerline of pedestrian monitor door
Image
Published
09/25/2023 8:42 PM
Attach mounting template
Image
Published
09/25/2023 8:44 PM
Mark location of 3.2-mm (1/8-inch) mounting holes
Image
Published
09/25/2023 8:46 PM
Mark location of 8-mm (5/16-inch) hole for wire passage
Image
Published
09/25/2023 8:47 PM
Insert rubber grommet in wire passage hole
Image
Published
09/25/2023 8:48 PM
Feed wiring connector through grommet
Image
Published
09/25/2023 8:50 PM
Feed wiring connector through grommet2
Image
Published
09/25/2023 8:51 PM
Mount new sensor
Image
Published
09/25/2023 8:52 PM
Mount new sensor2
Image
Published
09/25/2023 8:53 PM
Tighten two (2) mounting screws
Image
Published
09/25/2023 8:54 PM
Route wiring through clamp and connect
Image
Published
09/25/2023 8:55 PM
Adjust angle of the radar antenna
Image
Published
09/25/2023 8:56 PM
Adjust angle of the radar antenna2
Image
Published
09/25/2023 8:58 PM
Disconnect existing SPY-2 wiring
Image
Published
09/25/2023 8:59 PM
Route new cable to TB2
Image
Published
09/25/2023 9:01 PM
Connect red wire to TB2, Pin 16
Image
Published
09/25/2023 9:02 PM
Connect red wire to TB2, Pin 16 (2)
Image
Published
09/25/2023 9:03 PM
fork connector
Image
Published
09/25/2023 9:04 PM
Connect both black and white wires to TB2, Pin 15
Image
Published
09/25/2023 9:06 PM
Connect green wire to TB2, Pin 6
Image
Published
09/25/2023 9:34 PM
Apply sealant if needed
Image
Published
09/25/2023 9:36 PM
LD-260 Disconnect Switch Power On
Image
Published
05/04/2023 3:37 PM
IXIO-DT1 green sensor light will illuminate
Image
Published
09/25/2023 9:37 PM
Verify occupancy sensor functionality
Image
Published
09/25/2023 9:38 PM
Verify occupancy sensor functionality2
Image
Published
09/25/2023 9:39 PM
Install Occupancy Sensor Cover
Image
Published
06/02/2023 4:26 PM
Occupancy Sensor Sealant Application
Image
Published
06/02/2023 4:30 PM
Remove Magnet from Tamper.PNG
Image
Published
09/28/2023 9:37 AM
Remove Magnet on Tamper Switch
Image
Published
06/02/2023 4:31 PM
DET-RPM-RAP-CM15

Install the BEA IXIO-DT1 occupancy sensor on the pedestrian radiation portal monitor (RPM). The existing Visonic SPY-2 infrared curtain sensor is abandoned in place.

Equipment Hierarchy
Rapiscan PM-700 Pedestrian Monitor
Frequency
Upon failure of the Visonic SPY-2 infrared curtain occupancy sensor
Technician Level
Technician Level
Technician 2
x 2
Duration
Time increment
minutes
Length of time
120
Tools Required
Keys to access RPM
Magnets and adhesive tape to disable door tamper switches
Medium Phillips (PH2) screwdriver
Cordless drill
3.2-mm (1/8-inch) drill bit (for metal)
8-mm (5/16-inch) drill bit (for metal)
Deburring tool
safety glasses
Gloves (heavy duty)
Wire stripper
Wire crimping tool
Orange/yellow safety vest
Safety shoes
Protective headwear: glasses, hard hat
Orange traffic cones
Materials Required
BEA IXIO-DT1 Dual Technology Occupancy Sensor (Rapiscan Part #6692W)
Wiring crimp connector, fork type, 18-20 gauge
Silicone sealant, or equivalent
8-mm (5/16-inch) rubber hole grommet
Cable ties, or equivalent
Originators
Brian Tucker
Erica Kilgannon
Mark Melany
Originating Organization
Rapiscan Systems; PNNL
Approver
Cody Hostick
Additional Retest Requirements Information

Verify occupancy sensor functionality

Final Documentation
Corrective maintenance report
Departmental Coordination

Prior to arrival, notify operators concerning expected work, duration, and anticipated alarms and fault indications.

Date of Origin
Version #
Revision Description

Updated LD-260 images to re-usable standardized content.  Updated instructions to standardized re-usable content. 

Revision Date
Revision Author
Step 1
Step 2

7457 - 7420 - Verify narrow field radar antenna is installed; Remark:7421

Step 00
Step 3

8887 - 8877 - Mark location of 3.2-mm (1/8-inch) mounting holes; Remark:8876

Step 00
Step 4

8940 - 8935 - Drill two (2) mounting holes; Remark:8934

Step 00
Step 5

8918 - 8917 - Feed wiring connector through grommet; Remark:8915

Step 00
Step 6

8963 - 8962 - Disconnect existing SPY-2 wiring; Remark:8961

Step 00

8965 - 8958 - Connect red wire to TB2, Pin 16; Remark:8956

Step 00
Step 7
Document Type
Corrective Maintenance Procedure
Percent Complete
100.00
Percent Complete W/Media
100.00