Last Updated: 04/24/2025 1:44 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Rapiscan PM-700 Pedestrian Monitor
Device
Published
06/20/2024 11:38 AM
Rapiscan VM-250 Vehicle Monitor
Device
Published
10/14/2024 9:50 AM
Rapiscan TM-850 Rail Monitor
Device
Published
09/18/2024 10:28 AM
Rapiscan CM-267 Conveyor Monitor
Device
Published
06/27/2024 1:02 PM
1402 - 7927 - Establish Initial Conditions; Remark:
Procedure Step
Published
09/30/2022 1:47 PM
7927 - Establish Initial Conditions
Instruction
Published
07/12/2023 12:23 AM
7268 - 7231 - Close lane; Remark:7233
Procedure Step
Published
04/27/2023 7:01 PM
9053 - Warning : Traffic should temporarily be rerouted or halted during conduction of this pr...
Annotation
Published
09/27/2023 9:09 AM
7231 - Close lane
Instruction
Published
04/18/2023 1:00 PM
7233 - Use orange safety (traffic control) cones to setup barriers. Practice establi...
Remark
Published
04/24/2023 12:18 PM
7269 - 7232 - Open RPM door; Remark:7234
Procedure Step
Published
04/27/2023 7:02 PM
7232 - Open RPM door
Instruction
Published
04/18/2023 1:02 PM
7234 - Open all doors needed to access components.
Remark
Published
04/19/2025 7:48 PM
7270 - 7235 - Power off RPM; Remark:7236
Procedure Step
Published
09/01/2023 7:57 PM
7235 - Power off RPM
Instruction
Published
04/24/2023 12:30 PM
7236 - Move LD-260 switch to OFF position. The PWR ON
Remark
Published
04/27/2023 4:25 PM
8070 - 8066 - Disconnect upper left connector; Remark:8065
Procedure Step
Published
07/31/2023 1:54 PM
8066 - Disconnect upper left connector
Instruction
Published
07/31/2023 1:49 PM
8065 - The power input connector is a three-pin Molex. Both LEDs should be off when ...
Remark
Published
07/31/2023 1:54 PM
8077 - 8076 - Uninstall Faulty Fuse; Remark:
Procedure Step
Published
07/31/2023 4:31 PM
8076 - Uninstall Faulty Fuse
Instruction
Published
07/31/2023 4:31 PM
8075 - 8074 - Remove switch retaining nut; Remark:8073
Procedure Step
Published
07/31/2023 4:38 PM
8074 - Remove switch retaining nut
Instruction
Published
07/31/2023 4:32 PM
8073 - A small box end or crescent wrench may be required to loosen the switch retai...
Remark
Published
07/31/2023 4:38 PM
8084 - 8083 - Remove four cover plate screws; Remark:8082
Procedure Step
Published
07/31/2023 7:46 PM
8083 - Remove four cover plate screws
Instruction
Published
07/31/2023 7:44 PM
8082 -
Remark
Published
07/31/2023 7:46 PM
8085 - 8081 - Remove cover plate; Remark:8080
Procedure Step
Published
07/31/2023 7:52 PM
8081 - Remove cover plate
Instruction
Published
07/31/2023 7:51 PM
8080 -
Remark
Published
07/31/2023 7:52 PM
8086 - 8079 - Remove failed fuse; Remark:8078
Procedure Step
Published
07/31/2023 7:54 PM
8079 - Remove failed fuse
Instruction
Published
07/31/2023 7:53 PM
8078 - Carefully pull or pry the failed fuse from holder.
Remark
Published
07/31/2023 7:54 PM
3397 - 3395 - Label faulty component; Remark:3396
Procedure Step
Published
07/21/2024 6:59 AM
3395 - Label faulty component
Instruction
Published
08/07/2021 11:07 AM
3396 - Use tag or tape. Include date of removal, description of failure symptoms, co...
Remark
Published
08/09/2021 11:35 AM
8097 - 8096 - Install New Fuse; Remark:
Procedure Step
Published
07/31/2023 7:56 PM
8096 - Install New Fuse
Instruction
Published
07/31/2023 7:55 PM
10323 - 10322 - Place the new fuse in the fuse holder.; Remark:
Procedure Step
Published
11/17/2023 7:19 PM
10322 - Place the new fuse in the fuse holder.
Instruction
Published
11/17/2023 7:18 PM
8098 - 8094 - Install cover plate; Remark:
Procedure Step
Published
07/31/2023 7:56 PM
8094 - Install cover plate
Instruction
Published
07/31/2023 7:56 PM
8099 - 8093 - Install four screws; Remark:
Procedure Step
Published
07/31/2023 7:57 PM
8093 - Install four screws
Instruction
Published
07/31/2023 7:57 PM
8100 - 8092 - Install switch retaining nut; Remark:
Procedure Step
Published
07/31/2023 7:58 PM
8092 - Install switch retaining nut
Instruction
Published
07/31/2023 7:57 PM
7279 - 7249 - Return equipment to normal operating condition; Remark:
Procedure Step
Published
04/27/2023 4:13 PM
7249 - Return equipment to normal operating condition
Instruction
Published
04/08/2025 3:22 PM
8089 - 8088 - Reconnect upper left connector; Remark:8087
Procedure Step
Published
07/31/2023 8:06 PM
8088 - Reconnect upper left connector
Instruction
Published
07/31/2023 8:01 PM
8087 - When the connector is reconnected, the AC LED should be lit....
Remark
Published
07/31/2023 8:05 PM
7280 - 7250 - Power on RPM; Remark:7251
Procedure Step
Published
04/27/2023 4:14 PM
7250 - Power on RPM
Instruction
Published
05/01/2023 8:31 AM
7251 - Move LD-260 switch to ON position. The LED PWR ON
Remark
Published
05/10/2023 3:14 PM
7281 - 7252 - Verify RPM start-up; Remark:7253
Procedure Step
Published
04/20/2025 3:26 PM
7252 - Verify RPM start-up
Instruction
Published
04/27/2023 2:23 PM
7253 - RPM will perform a power on self-test (POST) and collect a background radiati...
Remark
Published
05/10/2023 3:14 PM
7282 - 7254 - Confirm network connection; Remark:7255
Procedure Step
Published
04/27/2023 4:15 PM
7254 - Confirm network connection
Instruction
Published
04/27/2023 2:22 PM
7255 - Contact operators to confirm communications have been reestablished between RPM ...
Remark
Published
05/10/2023 3:15 PM
7283 - 7256 - Close and lock all RPM doors; Remark:
Procedure Step
Published
09/01/2023 11:45 PM
7256 - Close and lock all RPM doors
Instruction
Published
04/27/2023 2:21 PM
7842 - 7820 - Inform system operators upon completion of maintenance action; Remark:
Procedure Step
Published
07/07/2023 11:15 PM
7820 - Inform system operators upon completion of maintenance action
Instruction
Published
07/07/2023 10:02 PM
322 - 321 - Document maintenance actions; Remark:
Procedure Step
Published
06/17/2021 9:49 AM
321 - Document maintenance actions
Instruction
Published
04/21/2025 11:19 AM
2869 - 2585 - Document maintenance performed; Remark:2866
Procedure Step
Published
06/18/2021 5:58 PM
2585 - Document maintenance performed
Instruction
Published
07/09/2021 12:15 PM
2866 - Record observations, times, and results for the maintenance report.
Remark
Published
04/21/2025 11:39 AM
4706 - 4705 - Submit report; Remark:4864
Procedure Step
Published
06/29/2022 9:50 AM
4705 - Submit report
Instruction
Published
06/29/2022 9:50 AM
4864 - As specified by management or contractual obligations.
Remark
Published
07/28/2022 1:36 PM
Corrective Maintenance Procedure
Document Type
Published
03/02/2020 3:32 PM
20 minutes
Duration
Published
05/18/2020 5:44 PM
Upon failure of the fuse
Frequency
Published
11/17/2023 6:27 PM
Warning
Annotation Type
Published
03/02/2020 3:25 PM
Technician 2
Skill Level
Published
04/09/2020 1:17 AM
Keys to access RPM
Replacement Parts
Published
04/27/2023 6:56 PM
Small Phillips (PH1) screwdriver
Tools
Published
05/14/2020 2:48 PM
Medium Phillips (PH2) screwdriver
Tools
Published
04/24/2020 4:40 PM
Orange/yellow safety vest
Replacement Parts
Published
04/27/2023 6:56 PM
Safety shoes
Replacement Parts
Published
04/27/2023 6:56 PM
safety glasses
Replacement Parts
Published
07/02/2023 4:48 PM
Ladder; 2 meters, 6 feet tall; non-conducting if required
Replacement Parts
Published
07/02/2023 4:48 PM
Orange traffic cones
Replacement Parts
Published
04/27/2023 6:56 PM
Small crescent wrench
Tools
Published
07/31/2023 10:46 AM
LD-260 Disconnect Switch Power Off
Image
Published
04/24/2023 12:49 PM
Unplugged LD-260
Image
Published
11/17/2023 6:50 PM
LD-260 Switch Power Off
Image
Published
11/17/2023 6:49 PM
LD-260 Nut
Image
Published
11/17/2023 7:06 PM
Remove four cover plate screws
Image
Published
07/31/2023 7:46 PM
LD-260 Cover Removed
Image
Published
11/17/2023 8:25 PM
LD-260 Fuse
Image
Published
11/17/2023 7:10 PM
LD-260
Image
Published
07/31/2023 7:42 PM
LD-260 Disconnect Switch Power On
Image
Published
05/04/2023 3:37 PM
DET-RPM-RAP-CM05

Replace fuse in LD-260 load disconnect

Equipment Hierarchy
Rapiscan PM-700 Pedestrian Monitor
Rapiscan VM-250 Vehicle Monitor
Rapiscan TM-850 Rail Monitor
Rapiscan CM-267 Conveyor Monitor
Frequency
Upon failure of the fuse
Technician Level
Technician Level
Technik 2
x 1
Duration
Time increment
20 minutes
Length of time
20
Tools Required
Keys to access RPM
Small Phillips (PH1) screwdriver
Medium Phillips (PH2) screwdriver
Orange/yellow safety vest
Safety shoes
safety glasses
Ladder; 2 meters, 6 feet tall; non-conducting if required
Orange traffic cones
Small crescent wrench
Materials Required
RPM Maintenance Guide Rev 2.0
5 Amp fast acting fuse 5x20 mm
Originators
David Alexander
Originating Organization
PNNL
Approver
Craig Stinson
Safety Concerns
Traffic
Final Documentation
Corrective maintenance report
Departmental Coordination

Prior to arrival, notify operators concerning expected work, duration, and anticipated alarms and fault indications.

Date of Origin
Version
0.00
Version #
Revision Description

Updated pillar names

Revision Date
Revision Author
Step 1

7268 - 7231 - Close lane; Remark:7233

Step 00
Step 2
Prevádzka
Step 4
Document Type
Corrective Maintenance Procedure
Percent Complete
100.00
Percent Complete W/Media
100.00