Last Updated: 04/24/2025 1:44 AM
The following table lists all the components that make up the document.
Inspect and replace desiccant in Rapiscan radiation portal monitor (RPM). (the frequency of required desiccant replacement will vary from site to site, type and quantity of desiccant and possibly season to season; the recommendation is to start monthly and adjust as necessary).
5 minutes per pedestrian monitor; 10 minutes per vehicle monitor; 20 minutes per rail monitor (additional 10 minutes with protective cage)
Prior to arrival, notify operators concerning expected work, duration, and anticipated alarms and fault indications.
7928 - 7927 - Establish Initial Conditions; Remark:
7927 - Establish Initial Conditions
Establish Initial Conditions
7969 - 7968 - Close lane; Remark:8224
8226 - Warning : Traffic should temporarily be rerouted or halted during this procedure to ens...
Traffic should temporarily be rerouted or halted during this procedure to ensure safety and prevent unscreened vehicles from passing.
7968 - Close lane
Close lane
8224 - Use orange safety (traffic control) cones to setup barriers. Practice establi...
Use orange safety (traffic control) cones to setup barriers. Practice established safety protocols.
7926 - 7924 - Open RPM door.; Remark:8223
7924 - Open RPM door.
Open RPM door.
8223 - Open all doors needed to access components.
Open all doors needed to access components.
7270 - 7235 - Power off RPM; Remark:7236
7235 - Power off RPM
Power off RPM
7236 - Move LD-260 switch to OFF position. The PWR ON
Move LD-260 switch to OFF position. The PWR ON LED will turn off.

7964 - 7963 - Inspect Desiccant; Remark:
7963 - Inspect Desiccant
Inspect Desiccant
7959 - 7958 - Inspect existing desiccant bags.; Remark:8233
7958 - Inspect existing desiccant bags.
Inspect existing desiccant bags.
8233 - Inspect existing desiccant bags visually and by feel. If the bags are only pa...
Inspect existing desiccant bags visually and by feel. If the bags are only partially depleted, experience will indicate if the bags will last until the next inspection date or if they should be replaced now. Replace it if it feels like slush; it can remain if solid particles are present.
7960 - 7956 - Document the current date on the existing bag if no replacement is required.; Remark:
7956 - Document the current date on the existing bag if no replacement is required.
Document the current date on the existing bag if no replacement is required.
7961 - 7955 - Inspect interior of RPM cabinets.; Remark:7954
7955 - Inspect interior of RPM cabinets.
Inspect interior of RPM cabinets.
7954 - Inspect cabinets for dirt, debris, and signs of water or rodent/insect infest...
Inspect cabinets for dirt, debris, and signs of water or rodent/insect infestation. Make note of any problems observed in operator log.
7962 - 7953 - Clean cabinet interior.; Remark:8227
7953 - Clean cabinet interior.
Clean cabinet interior.
8227 - Use absorbent cleaning rags if required.
Use absorbent cleaning rags if required.
7952 - 7951 - Replace Desiccant; Remark:
7951 - Replace Desiccant
Replace Desiccant
7947 - 7945 - Remove exhausted desiccant bag(s); Remark:
7945 - Remove exhausted desiccant bag(s)
Remove exhausted desiccant bag(s)
7948 - 7944 - Install new desiccant bag(s) in place of removed bag; Remark:
7975 - Caution : Place bags away from electrical connections to avoid damage if desiccant leak...
Place bags away from electrical connections to avoid damage if desiccant leaks. Do not place desiccant bag on top of the neutron detector due to leaking CaCl desiccant bags causing issues in the field. A different location needs to be determined
7944 - Install new desiccant bag(s) in place of removed bag
Install new desiccant bag(s) in place of removed bag
7949 - 7943 - Properly dispose of exhausted desiccant bag; Remark:
7943 - Properly dispose of exhausted desiccant bag
Properly dispose of exhausted desiccant bag
7279 - 7249 - Return equipment to normal operating condition; Remark:
7249 - Return equipment to normal operating condition
Return equipment to normal operating condition
7280 - 7250 - Power on RPM; Remark:7251
7250 - Power on RPM
Power on RPM
7251 - Move LD-260 switch to ON position. The LED PWR ON
Move LD-260 switch to ON position. The LED PWR ON will illuminate.

7281 - 7252 - Verify RPM start-up; Remark:7253
7252 - Verify RPM start-up
Verify RPM start-up
7253 - RPM will perform a power on self-test (POST) and collect a background radiati...
RPM will perform a power on self-test (POST) and collect a background radiation measurement.
7282 - 7254 - Confirm network connection; Remark:7255
7254 - Confirm network connection
Confirm network connection
7255 - Contact operators to confirm communications have been reestablished between RPM ...
7283 - 7256 - Close and lock all RPM doors; Remark:
7256 - Close and lock all RPM doors
Close and lock all RPM doors
7842 - 7820 - Inform system operators upon completion of maintenance action; Remark:
7820 - Inform system operators upon completion of maintenance action
Inform system operators upon completion of maintenance action
322 - 321 - Registre las tareas de mantenimiento; Remark:
321 - Registre las tareas de mantenimiento
Registre las tareas de mantenimiento
2869 - 2585 - Registre el mantenimiento realizado; Remark:2866
2585 - Registre el mantenimiento realizado
Registre el mantenimiento realizado
2866 - Registre las observaciones, las horas y los resultados para el informe de manten...
Registre las observaciones, las horas y los resultados para el informe de mantenimiento correctivo.
4706 - 4705 - Envíe el informe; Remark:4864
4705 - Envíe el informe
Envíe el informe
4864 - Según lo especificado por la gerencia o las obligaciones contractuales.
Según lo especificado por la gerencia o las obligaciones contractuales.