Last Updated: 04/24/2025 1:44 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Rapiscan VM-250 Vehicle Monitor
Device
Published
10/14/2024 9:50 AM
Rapiscan PM-700 Pedestrian Monitor
Device
Published
06/20/2024 11:38 AM
Rapiscan TM-850 Rail Monitor
Device
Published
09/18/2024 10:28 AM
7621 - 1401 - Establish Initial Conditions; Remark:
Procedure Step
Published
06/29/2023 5:37 PM
1401 - Establish Initial Conditions
Instruction
Published
09/30/2022 3:14 PM
7622 - 7592 - Inform system operators; Remark:11335
Procedure Step
Published
04/20/2025 10:15 AM
7592 - Inform system operators
Instruction
Published
06/29/2023 3:20 PM
11335 - Upon arrival, brief system operators on expected work, duration, anticipated ...
Remark
Published
04/20/2025 10:14 AM
7623 - 7593 - Brief system operators on expected work and duration before starting work&nbs...; Remark:
Procedure Step
Published
06/29/2023 4:56 PM
7593 - Brief system operators on expected work and duration before starting work&nbs...
Instruction
Published
06/29/2023 3:22 PM
7624 - 7594 - Close lane and set up barriers to establish a safety watch; Remark:7595
Procedure Step
Published
06/29/2023 4:57 PM
7594 - Close lane and set up barriers to establish a safety watch
Instruction
Published
06/29/2023 3:28 PM
7595 - Use orange safety (traffic control) cones or equivalent per site-specific saf...
Remark
Published
06/29/2023 3:33 PM
7625 - 7596 - Perform +12 VDC Battery Load Test; Remark:
Procedure Step
Published
06/29/2023 4:58 PM
7596 - Perform +12 VDC Battery Load Test
Instruction
Published
06/29/2023 3:38 PM
7626 - 7597 - Unlock and open RPM cabinets doors as required to access cabinet interior...; Remark:
Procedure Step
Published
06/29/2023 4:59 PM
7597 - Unlock and open RPM cabinets doors as required to access cabinet interior...
Instruction
Published
06/29/2023 3:40 PM
7270 - 7235 - Power off RPM; Remark:7236
Procedure Step
Published
09/01/2023 7:57 PM
7235 - Power off RPM
Instruction
Published
04/24/2023 12:30 PM
7236 - Move LD-260 switch to OFF position. The PWR ON
Remark
Published
04/27/2023 4:25 PM
7629 - 7600 - Switch ac power off so green window is visible; Remark:7628
Procedure Step
Published
04/13/2025 6:19 PM
7599 - Warning : 120/220 Vac will be present at the input side of the ac circuit breaker.&nbsp...
Annotation
Published
06/29/2023 3:43 PM
7600 - Switch ac power off so green window is visible
Instruction
Published
04/13/2025 5:48 PM
7628 - Breaker Off
Remark
Published
06/29/2023 5:01 PM
7280 - 7250 - Power on RPM; Remark:7251
Procedure Step
Published
04/27/2023 4:14 PM
7250 - Power on RPM
Instruction
Published
05/01/2023 8:31 AM
7251 - Move LD-260 switch to ON position. The LED PWR ON
Remark
Published
05/10/2023 3:14 PM
11339 - 6914 - Verify battery operation; Remark:11338
Procedure Step
Published
04/20/2025 1:30 PM
6914 - Verify battery operation
Instruction
Published
12/21/2022 12:41 PM
11338 - If the RPM does not power on, replace battery by performing procedure ...
Remark
Published
04/20/2025 1:28 PM
7633 - 7606 - Measure and record battery voltage; Remark:7632
Procedure Step
Published
06/29/2023 5:09 PM
7605 - Standard : Using a DMM, the battery voltage should be approximately 12 to 13 VDC.
Annotation
Published
06/29/2023 4:01 PM
7606 - Measure and record battery voltage
Instruction
Published
06/29/2023 4:02 PM
7632 - VDC Battery
Remark
Published
06/29/2023 5:09 PM
7634 - 7607 - Wait approximately 1 hour; Remark:
Procedure Step
Published
06/29/2023 5:10 PM
7607 - Wait approximately 1 hour
Instruction
Published
06/29/2023 4:05 PM
7635 - 7608 - Re-measure battery voltage; Remark:7609
Procedure Step
Published
06/29/2023 5:11 PM
7608 - Re-measure battery voltage
Instruction
Published
06/29/2023 4:09 PM
7609 - If the battery voltage is less than 11 VDC, replace the battery by performing...
Remark
Published
06/29/2023 4:11 PM
7636 - 7610 - Switch ac power on so red window is visible; Remark:7611
Procedure Step
Published
06/29/2023 5:12 PM
7610 - Switch ac power on so red window is visible
Instruction
Published
06/29/2023 4:13 PM
7611 - Amber "ac" light on LD-260 should illuminate.
Remark
Published
04/13/2025 5:48 PM
7637 - 7612 - Close and lock RPM cabinets; Remark:
Procedure Step
Published
06/29/2023 5:12 PM
7612 - Close and lock RPM cabinets
Instruction
Published
06/29/2023 4:23 PM
7279 - 7249 - Return equipment to normal operating condition; Remark:
Procedure Step
Published
04/27/2023 4:13 PM
7249 - Return equipment to normal operating condition
Instruction
Published
04/08/2025 3:22 PM
7282 - 7254 - Confirm network connection; Remark:7255
Procedure Step
Published
04/27/2023 4:15 PM
7254 - Confirm network connection
Instruction
Published
04/27/2023 2:22 PM
7255 - Contact operators to confirm communications have been reestablished between RPM ...
Remark
Published
05/10/2023 3:15 PM
7640 - 7616 - Close, reopen, and close cabinet doors to clear all tampers from fault queue; Remark:
Procedure Step
Published
06/29/2023 5:17 PM
7616 - Close, reopen, and close cabinet doors to clear all tampers from fault queue
Instruction
Published
06/29/2023 4:42 PM
7641 - 7617 - Open lane; Remark:
Procedure Step
Published
06/29/2023 5:17 PM
7617 - Open lane
Instruction
Published
06/29/2023 4:43 PM
7842 - 7820 - Inform system operators upon completion of maintenance action; Remark:
Procedure Step
Published
07/07/2023 11:15 PM
7820 - Inform system operators upon completion of maintenance action
Instruction
Published
07/07/2023 10:02 PM
322 - 321 - Document maintenance actions; Remark:
Procedure Step
Published
06/17/2021 9:49 AM
321 - Document maintenance actions
Instruction
Published
04/21/2025 11:19 AM
2869 - 2585 - Document maintenance performed; Remark:2866
Procedure Step
Published
06/18/2021 5:58 PM
2585 - Document maintenance performed
Instruction
Published
07/09/2021 12:15 PM
2866 - Record observations, times, and results for the maintenance report.
Remark
Published
04/21/2025 11:39 AM
4706 - 4705 - Submit report; Remark:4864
Procedure Step
Published
06/29/2022 9:50 AM
4705 - Submit report
Instruction
Published
06/29/2022 9:50 AM
4864 - As specified by management or contractual obligations.
Remark
Published
07/28/2022 1:36 PM
Routine Maintenance Procedure
Document Type
Published
03/02/2020 3:31 PM
Semi-annually
Frequency
Published
11/03/2022 2:10 PM
Warning
Annotation Type
Published
03/02/2020 3:25 PM
Standard
Annotation Type
Published
03/02/2020 3:25 PM
Technician 2
Skill Level
Published
04/09/2020 1:17 AM
Keys for RPM
Replacement Parts
Published
06/20/2023 4:47 PM
Reflective safety vest if applicable
Replacement Parts
Published
06/29/2023 5:46 PM
Safety glasses if applicable
Replacement Parts
Published
06/29/2023 5:46 PM
Traffic control cones or equivalent
Replacement Parts
Published
06/29/2023 5:46 PM
Digital multimeter DMM
Replacement Parts
Published
06/29/2023 5:46 PM
LD-260 Disconnect Switch Power Off
Image
Published
04/24/2023 12:49 PM
AC Circuit Breaker Off_0.png
Image
Published
06/29/2023 4:24 PM
LD-260 Disconnect Switch Power On
Image
Published
05/04/2023 3:37 PM
Battery VDC
Image
Published
06/29/2023 4:04 PM
AC Circuit Breaker On_0.png
Image
Published
06/29/2023 4:20 PM
DET-RPM-RAP-RM04

Perform +12 volts direct current (VDC) battery load test.

Equipment Hierarchy
Rapiscan VM-250 Vehicle Monitor
Rapiscan PM-700 Pedestrian Monitor
Rapiscan TM-850 Rail Monitor
Frequency
Semi-annually
Technician Level
Technician Level
Technician 2
x 1
Duration
Length of time
80
Tools Required
Keys for RPM
Reflective safety vest if applicable
Safety glasses if applicable
Traffic control cones or equivalent
Digital multimeter DMM
Materials Required
Applicable TSA Operations and Service Manuals
Originators
Craig Stinson
Bailey Toon
Originating Organization
PNNL
Safety Concerns
Electrical
Final Documentation
Routine maintenance report
Departmental Coordination

Coordinate site access with system operators

Date of Origin
Version
0.00
Preparation
Step 1
Step 2

7635 - 7608 - Re-measure battery voltage; Remark:7609

Step 00
Document Type
Routine Maintenance Procedure
Percent Complete
100.00
Percent Complete W/Media
100.00