Last Updated: 04/24/2025 1:43 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Rapiscan PM-700 Pedestrian Monitor
Device
Published
06/20/2024 11:38 AM
7478 - 1401 - Establish Initial Conditions; Remark:
Procedure Step
Published
09/01/2023 7:48 PM
1401 - Establish Initial Conditions
Instruction
Published
09/30/2022 3:14 PM
7452 - 7231 - Close lane; Remark:7415
Procedure Step
Published
06/02/2023 5:12 PM
7231 - Close lane
Instruction
Published
04/18/2023 1:00 PM
7415 - Re-route pedestrian traffic.
Remark
Published
06/02/2023 1:08 PM
7453 - 7232 - Open RPM door; Remark:7267
Procedure Step
Published
06/02/2023 5:24 PM
7232 - Open RPM door
Instruction
Published
04/18/2023 1:02 PM
7267 - Open all doors needed to access components.
Remark
Published
09/16/2023 4:54 PM
7454 - 7290 - Disable tamper switches; Remark:7416
Procedure Step
Published
06/02/2023 5:25 PM
7290 - Disable tamper switches
Instruction
Published
05/01/2023 8:14 AM
7416 - Use a magnet to disable tamper switches for all open doors. Use adhesive tape...
Remark
Published
06/02/2023 1:18 PM
7270 - 7235 - Power off RPM; Remark:7236
Procedure Step
Published
09/01/2023 7:57 PM
7235 - Power off RPM
Instruction
Published
04/24/2023 12:30 PM
7236 - Move LD-260 switch to OFF position. The PWR ON
Remark
Published
04/27/2023 4:25 PM
7479 - 7417 - Prepare New Occupancy Sensor; Remark:
Procedure Step
Published
06/02/2023 6:13 PM
7417 - Prepare New Occupancy Sensor
Instruction
Published
06/02/2023 1:39 PM
7456 - 7418 - Remove cover from new occupancy sensor; Remark:7419
Procedure Step
Published
06/02/2023 5:27 PM
7418 - Remove cover from new occupancy sensor
Instruction
Published
06/02/2023 1:43 PM
7419 - Use a slotted screwdriver to pry the cover off from the side.
Remark
Published
04/13/2025 5:44 PM
7457 - 7420 - Verify narrow field radar antenna is installed; Remark:7421
Procedure Step
Published
04/13/2025 6:18 PM
7420 - Verify narrow field radar antenna is installed
Instruction
Published
04/13/2025 5:44 PM
7421 - The IXIO-DT1 should come with the narrow field antenna installed.
Remark
Published
06/02/2023 2:14 PM
8901 - If needed, the antenna can be changed. Remove cover. Install narrow field ant...
Remark
Published
09/25/2023 9:51 PM
7480 - 7422 - Uninstall Faulty Occupancy Sensor; Remark:
Procedure Step
Published
06/02/2023 9:42 PM
7422 - Uninstall Faulty Occupancy Sensor
Instruction
Published
06/02/2023 2:16 PM
7458 - 7423 - Remove Cover; Remark:7424
Procedure Step
Published
06/02/2023 5:28 PM
7423 - Remove Cover
Instruction
Published
06/02/2023 2:18 PM
7424 - If needed, use a sharp utility knife to cut sealant around edges of sensor. A...
Remark
Published
06/02/2023 2:21 PM
7459 - 7425 - Disconnect wire connector; Remark:7426
Procedure Step
Published
06/02/2023 5:29 PM
7425 - Disconnect wire connector
Instruction
Published
06/02/2023 2:48 PM
7426 - The wire connector is located on the right side of existing sensor.
Remark
Published
06/02/2023 2:53 PM
7460 - 7427 - Loosen two (2) mounting screws; Remark:7428
Procedure Step
Published
06/02/2023 5:30 PM
7429 - Note : Some existing occupancy sensors are installed using screws and nuts, ...
Annotation
Published
06/02/2023 3:09 PM
7427 - Loosen two (2) mounting screws
Instruction
Published
06/02/2023 2:56 PM
7428 - Use a medium Phillips (PH2) screwdriver. If screws and nuts were used, an adj...
Remark
Published
06/02/2023 3:04 PM
7461 - 7430 - Remove faulty occupancy sensor; Remark:7431
Procedure Step
Published
06/02/2023 5:31 PM
7430 - Remove faulty occupancy sensor
Instruction
Published
06/02/2023 3:11 PM
7431 - If a Wizard G3 sensor is being removed, push up on both sides to free the sen...
Remark
Published
09/29/2023 1:49 PM
3397 - 3395 - Label faulty component; Remark:3396
Procedure Step
Published
07/21/2024 6:59 AM
3395 - Label faulty component
Instruction
Published
08/07/2021 11:07 AM
3396 - Use tag or tape. Include date of removal, description of failure symptoms, co...
Remark
Published
08/09/2021 11:35 AM
7481 - 7432 - Install new occupancy sensor; Remark:
Procedure Step
Published
06/02/2023 9:46 PM
7432 - Install new occupancy sensor
Instruction
Published
06/02/2023 3:27 PM
7463 - 7433 - Mount new sensor; Remark:7434
Procedure Step
Published
06/02/2023 5:32 PM
7433 - Mount new sensor
Instruction
Published
06/02/2023 3:29 PM
7434 - First, slide left side onto mounting screw.
Remark
Published
04/13/2025 5:44 PM
9206 - Then, place right side over mounting screw and push down.
Remark
Published
09/29/2023 1:55 PM
7464 - 7435 - Tighten two (2) mounting screws; Remark:7436
Procedure Step
Published
06/02/2023 5:33 PM
7435 - Tighten two (2) mounting screws
Instruction
Published
06/02/2023 3:40 PM
7436 - Use medium Phillips (PH2) screwdriver. Take care not to overtighten.
Remark
Published
04/13/2025 5:45 PM
7482 - 7437 - Route wiring through clamp and connect; Remark:7488
Procedure Step
Published
06/02/2023 10:42 PM
7437 - Route wiring through clamp and connect
Instruction
Published
06/02/2023 3:53 PM
7488 - Clamp and Connect
Remark
Published
06/02/2023 10:49 PM
7465 - 7439 - Adjust angle of the radar antenna; Remark:7438
Procedure Step
Published
04/13/2025 6:19 PM
7439 - Adjust angle of the radar antenna
Instruction
Published
04/13/2025 5:45 PM
7438 - The angle is adjusted by manually rotating the antenna up or down. The defaul...
Remark
Published
09/29/2023 1:58 PM
7279 - 7249 - Return equipment to normal operating condition; Remark:
Procedure Step
Published
04/27/2023 4:13 PM
7249 - Return equipment to normal operating condition
Instruction
Published
04/08/2025 3:22 PM
7466 - 7440 - Hold door open; Remark:7441
Procedure Step
Published
06/02/2023 5:35 PM
7440 - Hold door open
Instruction
Published
06/02/2023 4:10 PM
7441 - Do not move door. Door must remain stationary to prevent occupancy.
Remark
Published
04/13/2025 5:45 PM
7280 - 7250 - Power on RPM; Remark:7251
Procedure Step
Published
04/27/2023 4:14 PM
7250 - Power on RPM
Instruction
Published
05/01/2023 8:31 AM
7251 - Move LD-260 switch to ON position. The LED PWR ON
Remark
Published
05/10/2023 3:14 PM
7468 - 7304 - Confirm RPM has restarted correctly; Remark:7487
Procedure Step
Published
06/02/2023 5:36 PM
7304 - Confirm RPM has restarted correctly
Instruction
Published
05/01/2023 8:31 AM
7487 - The SC-770 controller will display "OK" following Power On Self-Test (POST) a...
Remark
Published
06/02/2023 10:35 PM
7282 - 7254 - Confirm network connection; Remark:7255
Procedure Step
Published
04/27/2023 4:15 PM
7254 - Confirm network connection
Instruction
Published
04/27/2023 2:22 PM
7255 - Contact operators to confirm communications have been reestablished between RPM ...
Remark
Published
05/10/2023 3:15 PM
7470 - 7442 - Generate occupancy; Remark:7443
Procedure Step
Published
06/02/2023 5:37 PM
7442 - Generate occupancy
Instruction
Published
06/02/2023 4:19 PM
7443 - Create motion in front of occupancy sensor. While holding the door open and s...
Remark
Published
06/02/2023 4:21 PM
7471 - 7444 - Verify occupancy sensor functionality; Remark:7445
Procedure Step
Published
06/02/2023 5:38 PM
7444 - Verify occupancy sensor functionality
Instruction
Published
06/02/2023 4:32 PM
7445 - IXIO-DT1 green sensor light will illuminate.
Remark
Published
06/02/2023 4:35 PM
8973 - Left latch on the LCD screen will indicate a “closed” circuit.
Remark
Published
09/25/2023 11:05 PM
8974 - SC-770 status will read “OCCUPIED”.
Remark
Published
09/25/2023 11:06 PM
7472 - 7446 - Install sensor cover; Remark:7447
Procedure Step
Published
06/02/2023 5:38 PM
7446 - Install sensor cover
Instruction
Published
06/02/2023 4:37 PM
7447 - The cover should snap into place.
Remark
Published
06/02/2023 4:38 PM
7473 - 7448 - If needed, apply sealant; Remark:7449
Procedure Step
Published
06/02/2023 5:39 PM
7448 - If needed, apply sealant
Instruction
Published
06/02/2023 4:39 PM
7449 - If used outdoors, sealant should be applied to top and sides of cover. Do not...
Remark
Published
06/02/2023 4:41 PM
7474 - 7310 - Enable tamper switches; Remark:7451
Procedure Step
Published
06/02/2023 5:41 PM
7310 - Enable tamper switches
Instruction
Published
05/01/2023 8:36 AM
7451 - Remove magnets and/or adhesive tape from door tamper switches.
Remark
Published
04/13/2025 5:46 PM
7283 - 7256 - Close and lock all RPM doors; Remark:
Procedure Step
Published
09/01/2023 11:45 PM
7256 - Close and lock all RPM doors
Instruction
Published
04/27/2023 2:21 PM
7842 - 7820 - Inform system operators upon completion of maintenance action; Remark:
Procedure Step
Published
07/07/2023 11:15 PM
7820 - Inform system operators upon completion of maintenance action
Instruction
Published
07/07/2023 10:02 PM
322 - 321 - Document maintenance actions; Remark:
Procedure Step
Published
06/17/2021 9:49 AM
321 - Document maintenance actions
Instruction
Published
04/21/2025 11:19 AM
2869 - 2585 - Document maintenance performed; Remark:2866
Procedure Step
Published
06/18/2021 5:58 PM
2585 - Document maintenance performed
Instruction
Published
07/09/2021 12:15 PM
2866 - Record observations, times, and results for the maintenance report.
Remark
Published
04/21/2025 11:39 AM
4706 - 4705 - Submit report; Remark:4864
Procedure Step
Published
06/29/2022 9:50 AM
4705 - Submit report
Instruction
Published
06/29/2022 9:50 AM
4864 - As specified by management or contractual obligations.
Remark
Published
07/28/2022 1:36 PM
Corrective Maintenance Procedure
Document Type
Published
03/02/2020 3:32 PM
Instrument is not functioning correctly
Frequency
Published
12/19/2022 5:52 PM
Note
Annotation Type
Published
03/02/2020 3:25 PM
Technician 1
Skill Level
Published
05/14/2020 2:56 PM
Keys to access RPM
Replacement Parts
Published
04/27/2023 6:56 PM
Magnets and adhesive tape to disable door tamper switches
Replacement Parts
Published
06/02/2023 10:08 PM
Medium slotted screwdriver
Replacement Parts
Published
06/02/2023 10:08 PM
Medium Phillips (PH2) screwdriver
Tools
Published
04/24/2020 4:40 PM
Adjustable wrench
Replacement Parts
Published
06/02/2023 10:08 PM
Utility knife
Tools
Published
05/19/2020 1:54 PM
Orange/yellow safety vest
Replacement Parts
Published
04/27/2023 6:56 PM
Safety shoes
Replacement Parts
Published
04/27/2023 6:56 PM
Gloves
Replacement Parts
Published
05/10/2023 3:28 PM
Protective headwear: glasses, hard hat
Replacement Parts
Published
05/10/2023 3:31 PM
Orange traffic cones
Replacement Parts
Published
04/27/2023 6:56 PM
Disable tamper switch
Image
Published
09/07/2023 8:22 PM
Disable Tamper Switch
Image
Published
06/02/2023 2:28 PM
LD-260 Disconnect Switch Power Off
Image
Published
04/24/2023 12:49 PM
Remove Occupancy Sensor Cover
Image
Published
06/02/2023 2:38 PM
The IXIO-DT1 should come with the narrow field antenna installed
Image
Published
09/25/2023 8:35 PM
Verify narrow field radar antenna is installed
Image
Published
09/25/2023 8:38 PM
Verify narrow field radar antenna is installed 2
Image
Published
09/25/2023 8:39 PM
Uninstall Occupancy Sensor Cover
Image
Published
06/02/2023 2:37 PM
Disconnect Wire Connector
Image
Published
06/02/2023 2:53 PM
Loosen Two Mounting screws
Image
Published
06/02/2023 3:04 PM
Remove faulty Occupancy Sensor
Image
Published
09/29/2023 1:47 PM
Push Occupancy Sensor to the right
Image
Published
09/29/2023 1:48 PM
Mount new sensor
Image
Published
09/25/2023 8:52 PM
Push Down Over Mounting Screw to Install Occupancy Sensor
Image
Published
06/02/2023 3:51 PM
Tighten Occupancy Sensor Mounting Screws
Image
Published
06/02/2023 3:48 PM
Route wiring through clamp and connect
Image
Published
06/02/2023 3:55 PM
Adjust angle of the radar antenna
Image
Published
09/25/2023 8:56 PM
Adjust angle of the radar antenna2
Image
Published
09/25/2023 8:58 PM
LD-260 Disconnect Switch Power On
Image
Published
05/04/2023 3:37 PM
IXIO-DT1 green sensor light will illuminate
Image
Published
09/25/2023 9:37 PM
Verify occupancy sensor functionality
Image
Published
09/25/2023 9:38 PM
Verify occupancy sensor functionality2
Image
Published
09/25/2023 9:39 PM
Install Occupancy Sensor Cover
Image
Published
06/02/2023 4:26 PM
Occupancy Sensor Sealant Application
Image
Published
06/02/2023 4:30 PM
Remove Magnet from Tamper.PNG
Image
Published
09/28/2023 9:37 AM
Remove Magnet on Tamper Switch
Image
Published
06/02/2023 4:31 PM
DET-RPM-RAP-CM16

Replace a faulty BEA IXIO-DT1 occupancy sensor. This procedure can also be used to replace a faulty BEA Wizard G3 occupancy sensor. 

Equipment Hierarchy
Rapiscan PM-700 Pedestrian Monitor
Frequency
Instrument is not functioning correctly
Technician Level
Technician Level
Teknisyen 1
x 1
Duration
Length of time
30
Tools Required
Keys to access RPM
Magnets and adhesive tape to disable door tamper switches
Medium slotted screwdriver
Medium Phillips (PH2) screwdriver
Adjustable wrench
Utility knife
Orange/yellow safety vest
Safety shoes
Gloves
Protective headwear: glasses, hard hat
Orange traffic cones
Materials Required
BEA IXIO-DT1 Dual Technology Occupancy Sensor (Rapiscan Part #6692W)
Silicone sealant
Originators
Mike Papp
Brian Tucker
Erica Kilgannon
Originating Organization
Rapiscan Systems; PNNL
Approver
Cody Hostick
Safety Concerns
None
Final Documentation
Corrective Maintenance Report
Departmental Coordination

Prior to arrival, notify operators concerning expected work, duration, and anticipated alarms and fault indications. 

Date of Origin
Hazırlık
Step 1
Çalıştırma
Step 2

7457 - 7420 - Verify narrow field radar antenna is installed; Remark:7421

Step 00
Çalıştırma
Step 3

7460 - 7427 - Loosen two (2) mounting screws; Remark:7428

Step 00

3397 - 3395 - Arızalı bileşeni etiketleyin; Remark:3396

Step 00
Çalıştırma
Step 4
Çalıştırma
Step 5
Document Type
Corrective Maintenance Procedure
Percent Complete
100.00
Percent Complete W/Media
100.00