Last Updated: 04/24/2025 1:43 AM
The following table lists all the components that make up the document.
Replace the ethernet-to-fiber media converter (GarrettCom Magnum CS14P) on the radiation portal monitor (RPM).
Prior to arrival, notify operators concerning expected work, duration, and anticipated alarms and fault indications.
7371 - 1401 - Establish Initial Conditions; Remark:
1401 - Establish Initial Conditions
Establish Initial Conditions
7372 - 7231 - Close lane; Remark:7233
7261 - Warning : Traffic should temporarily be rerouted or halted during this procedure to ens...
Traffic should temporarily be rerouted or halted during this procedure to ensure safety and prevent unscreened vehicles from passing.
7231 - Close lane
Close lane
7233 - Use orange safety (traffic control) cones to setup barriers. Practice establi...
Use orange safety (traffic control) cones to setup barriers. Practice established safety protocols.
7373 - 7232 - Open RPM door; Remark:7267
7232 - Open RPM door
Open RPM door
7267 - Open all doors needed to access components.
Open all doors needed to access components.
7374 - 7235 - Power off RPM; Remark:7236
7235 - Power off RPM
Power off RPM
7236 - Move LD-260 switch to OFF position. The PWR ON
Move LD-260 switch to OFF position. The PWR ON LED will turn off.

7375 - 7356 - Uninstall Faulty Media Converter; Remark:
7356 - Uninstall Faulty Media Converter
Uninstall Faulty Media Converter
7376 - 7357 - Disconnect Ethernet and optical cables; Remark:7358
5291 - Note : It is good practice to verify all cables and connectors are labeled prior to ...
It is good practice to verify all cables and connectors are labeled prior to disconnection.
7357 - Disconnect Ethernet and optical cables
7358 - Magnum CS14P Premium Rated Converter Switch
Magnum CS14P Premium Rated Converter Switch

7377 - 7295 - Disconnect power wires; Remark:7359
7295 - Disconnect power wires
Disconnect power wires
7359 - Use a small precision screwdriver to loosen the screw

7378 - 5405 - Remove two (2) mounting screws; Remark:7360
5405 - Remove two (2) mounting screws
Remove two (2) mounting screws
7360 - Use medium Phillips head (PH2) screwdriver. Retain screws.

7379 - 7361 - Remove faulty media converter; Remark:
7361 - Remove faulty media converter
3397 - 3395 - Label faulty component; Remark:3396
3395 - Label faulty component
Label faulty component
3396 - Use tag or tape. Include date of removal, description of failure symptoms, co...
Use tag or tape. Include date of removal, description of failure symptoms, country, site, and lane number. Dispose per Nuclear Smuggling Detection and Deterrence (NSDD) guidance or contractual requirements.
7381 - 7362 - Install New Ethernet-to-Fiber Media Converter; Remark:
7362 - Install New Ethernet-to-Fiber Media Converter
Install New Ethernet-to-Fiber Media Converter
7382 - 7363 - Mount new media converter with two (2) screws; Remark:7396
7363 - Mount new media converter with two (2) screws
7396 - Use retained screws. Use medium Phillips (PH2) screwdriver.
Use retained screws. Use medium Phillips (PH2) screwdriver.

7383 - 7301 - Reconnect power wires; Remark:7364
462 - Caution : Correct placement of connectors and wiring is critical to proper operation.
Correct placement of connectors and wiring is critical to proper operation.
7301 - Reconnect power wires
Reconnect power wires
7364 - Insert power wires and use a small precision screwdriver to tighten the screw.

7384 - 7365 - Reconnect Ethernet and fiber cables; Remark:7366
462 - Caution : Correct placement of connectors and wiring is critical to proper operation.
Correct placement of connectors and wiring is critical to proper operation.
7365 - Reconnect Ethernet and fiber cables
7279 - 7249 - Return equipment to normal operating condition; Remark:
7249 - Return equipment to normal operating condition
Return equipment to normal operating condition
7386 - 7250 - Power on RPM; Remark:7367
7250 - Power on RPM
Power on RPM
7367 - Move LD-260 switch to ON position. The PWR ON
Move LD-260 switch to ON position. The PWR ON LED will illuminate.

7387 - 7368 - Verify power and connectivity; Remark:7369
7368 - Verify power and connectivity
7369 - POWER and communications LEDs will be constantly on or blinking.

7388 - 7304 - Confirm RPM has restarted correctly; Remark:7370
7304 - Confirm RPM has restarted correctly
Confirm RPM has restarted correctly
7370 - The SC-770 will perform Power On Self-Test (POST) followed by a background me...
The SC-770 will perform Power On Self-Test (POST) followed by a background measurement.
7389 - 7254 - Confirm network connection; Remark:7255
7254 - Confirm network connection
Confirm network connection
7255 - Contact operators to confirm communications have been reestablished between RPM ...
7390 - 7256 - Close and lock all RPM doors; Remark:
7256 - Close and lock all RPM doors
Close and lock all RPM doors
7842 - 7820 - Inform system operators upon completion of maintenance action; Remark:
7820 - Inform system operators upon completion of maintenance action
Inform system operators upon completion of maintenance action
322 - 321 - Document maintenance actions; Remark:
321 - Document maintenance actions
Document maintenance actions
2869 - 2585 - Document maintenance performed; Remark:2866
2585 - Document maintenance performed
Document maintenance performed
2866 - Record observations, times, and results for the maintenance report.
Record observations, times, and results for the maintenance report.
4706 - 4705 - Submit report; Remark:4864
4705 - Submit report
Submit report
4864 - As specified by management or contractual obligations.
As specified by management or contractual obligations.