Last Updated: 04/25/2025 1:39 AM
The following table lists all the components that make up the document.
Use the handheld radiation monitor to detect nuclear and other radioactive (RN) material.
247 - 257 - Prepare instrument; Remark:
257 - Prepare instrument
Prepare instrument
786 - 219 - Verify there are no sources of radiation near instrument; Remark:7
219 - Verify there are no sources of radiation near instrument
Verify there are no sources of radiation near instrument
7 - No Radiation symbol

4289 - 220 - Power on instrument; Remark:4287
220 - Power on instrument
Power on instrument
4287 - Select a mode for operation: AUDIO only
Select a mode for operation:
AUDIO only

4288 - VIBRATE only
VIBRATE only

4290 - 612 - Wait for instrument to complete start-up sequence; Remark:4286
612 - Wait for instrument to complete start-up sequence
Wait for instrument to complete start-up sequence
4286 - The unit is ready for operation when the period flashes every 20 seconds....
The unit is ready for operation when the period flashes every 20 seconds.

4291 - 319 - Perform operational test; Remark:4285
319 - Perform operational test
Perform operational test
4285 - It is recommended to perform an operational test daily before use. DET-HHD-ST...
It is recommended to perform an operational test daily before use. DET-HHD-STE-HRM-RM01, Handheld Radiation Monitor Operational Test.
4284 - 2903 - Operation; Remark:
2903 - Operation
Operation
4282 - 2904 - Wear instrument during shift; Remark:4281
2904 - Wear instrument during shift
Wear instrument during shift
4281 - The HRM should be worn on the body, such as forearm, lower leg, or on the tor...
The HRM should be worn on the body, such as forearm, lower leg, or on the torso as appropriate for the mission. Instrument remains powered on at all times.

4283 - 4280 - Update background as needed; Remark:4278
4280 - Update background as needed
Update background as needed
4278 - Background should be updated when:
Background should be updated when:

4279 - Moving to different surroundings Searching for high activi...
- Moving to different surroundings
- Searching for high activity sources of radiation
- U appears in LED display

4308 - 1096 - Respond to alarms; Remark:4307
1096 - Respond to alarms
Respond to alarms
4307 - When the instrument alarms, either move away from the source of radiation or ...
When the instrument alarms, either move away from the source of radiation or continue to locate the source.
4309 - 4305 - Follow standard operating procedures (SOPs); Remark:4304
4306 - Note : An alarm is indicated by a numeric value (1-9) in the gamma and/or neutron LE...
An alarm is indicated by a numeric value (1-9) in the gamma and/or neutron LED [light-emitting diode] display and a vibration or audible tone. If the gamma LED is slowly flashing 9, the dose rate is 120 micro-Sievert/hour (µSv/h) or greater.
4305 - Follow standard operating procedures (SOPs)
Follow standard operating procedures (SOPs)
4304 - SOPs will define acceptable radiation levels from RN material.
SOPs will define acceptable radiation levels from RN material.
410 - 7519 - Locate radioactive material; Remark:
7519 - Locate radioactive material
Locate radioactive material
4298 - 363 - Select mode; Remark:4882
363 - Select mode
Select mode
4882 - AUDIO mode is recommended for searching.
AUDIO mode is recommended for searching.

4299 - 408 - Survey close to surface of item; Remark:388
408 - Survey close to surface of item
Survey close to surface of item
388 - Maintain a distance of approximately 5 to 10 cm from surface of item. Do not ...
Maintain a distance of approximately 5 to 10 cm from surface of item. Do not make contact.
4300 - 366 - Survey slowly over entire item; Remark:2315
366 - Survey slowly over entire item
Survey slowly over entire item
2315 - Move instrument approximately 20 cm per second. Thoroughly survey all accessi...
Move instrument approximately 20 cm per second. Thoroughly survey all accessible surfaces of item.
4301 - 367 - Observe instrument response; Remark:4297
367 - Observe instrument response
Observe instrument response
4297 - Numerical values and audible alerts or vibration rate will increase with radi...
Numerical values and audible alerts or vibration rate will increase with radiation levels.

10647 - 10646 - Localize source of radiation; Remark:386
10646 - Localize source of radiation
Localize source of radiation
386 - Use crosshair technique to localize.
Use crosshair technique to localize.
4302 - 4296 - Reset threshold (if necessary); Remark:4295
4296 - Reset threshold (if necessary)
Reset threshold (if necessary)
4295 - If a 9 appears on the gamma display, press UPDATE and contin...
If a 9 appears on the gamma display, press UPDATE and continue searching. If a flashing 9 appears with a continuous alarm, stop searching. Pressing UPDATE will have no effect.
405 - 368 - Mark point(s) of interest; Remark:4277
368 - Mark point(s) of interest
Mark point(s) of interest
4277 - Place a marker (tape, pencil, etc.) on points exhibiting elevated radiation. ...
Place a marker (tape, pencil, etc.) on points exhibiting elevated radiation. There may be more than one point of interest.

4294 - 313 - Power off instrument; Remark:4293
313 - Power off instrument
Power off instrument
4293 - Move switch to OFF position.
Move switch to OFF position.