Last Updated: 04/25/2025 1:38 AM
The following table lists all the components that make up the document.
Upload spectra from the Smiths Detection RadSeeker CS to computer. Attach spectra to an event in RAVEN central alarm station (CAS).
This procedure is accurate for RAVEN software V2.4.1, Build 116.
Reinserted all pictures in PNG format. Made several small editorial changes throughout. Previous version was COM-RVN-SMD-OP01.
3719 - 3687 - Upload Spectra; Remark:
3687 - Upload Spectra
Upload Spectra
3720 - 220 - Power on instrument; Remark:2303
3666 - Note : Smiths Detection Connection Manager and Detector Controller must be installed...
Smiths Detection Connection Manager and Detector Controller must be installed on the computer before connecting the RadSeeker.
220 - Power on instrument
Power on instrument
2303 - Press and hold ENTER button until display powers on (3 to 5 ...
Press and hold ENTER button until display powers on (3 to 5 seconds).
3721 - 3601 - Connect instrument to computer; Remark:3607
3601 - Connect instrument to computer
Connect instrument to computer
3607 - Use USB-A to mini-USB cable provided with RadSeeker.
Use USB-A to mini-USB cable provided with RadSeeker.

3651 - If Detector Controller software does not start automatically, double click ic...
If Detector Controller software does not start automatically, double click icon. Click File, then Connect and select a COM port to connect to instrument.

3722 - 3635 - Wait for Detector Controller to open; Remark:3652
3635 - Wait for Detector Controller to open
Wait for Detector Controller to open
3652 - Detector Controller opens automatically to the Offload Data ...
Detector Controller opens automatically to the Offload Data tab.

5581 - If the computer cannot connect with the RadSeeker, refer to DET-HHD-SMD-OP04,...
If the computer cannot connect with the RadSeeker, refer to DET-HHD-SMD-OP04, RadSeeker Detector Controller Installation.
3723 - 3636 - Select files to transfer; Remark:3653
3667 - Note : RadSeeker stores three files for every identification measurement; it is only...
RadSeeker stores three files for every identification measurement; it is only necessary to upload and attach the N42.n42 file.
3668 - Note : Delete spectra from RadSeeker after upload by selecting Delete downloaded dat...
Delete spectra from RadSeeker after upload by selecting Delete downloaded data from detector.
3636 - Select files to transfer
Select files to transfer
3653 - Under Download, select which files to transfer to computer. ...
Under Download, select which files to transfer to computer. Choose All, Most recent, or Event number range.

3724 - 3637 - Select location to store files; Remark:3654
3637 - Select location to store files
Select location to store files
3654 - Select the location to save the files to by clicking Browse....
Select the location to save the files to by clicking Browse.

3725 - 3638 - Click Start Offloading; Remark:3655
3638 - Click Start Offloading
Click Start Offloading
3655 - The Download Status will display Offloaded when the file upl...
The Download Status will display Offloaded when the file upload is complete.

3700 - 3591 - Disconnect instrument from computer; Remark:3622
3591 - Disconnect instrument from computer
Disconnect instrument from computer
3727 - 3641 - Spektrumları ekleyin; Remark:
3641 - Spektrumları ekleyin
Spektrumları ekleyin
3728 - 3640 - RAVEN Olay Günlüğünü açın; Remark:3657
3640 - RAVEN Olay Günlüğünü açın
RAVEN Olay Günlüğünü açın
3729 - 3642 - Spektrumları eklemek için alarm olayına tıklayın; Remark:3658
3642 - Spektrumları eklemek için alarm olayına tıklayın
Spektrumları eklemek için alarm olayına tıklayın
3730 - 3643 - “Attach RIID”e (RIID Ekle) tıklayın; Remark:3659
3643 - “Attach RIID”e (RIID Ekle) tıklayın
“Attach RIID”e (RIID Ekle) tıklayın
3731 - 3644 - Click Import File; Remark:3660
3669 - Note : RadSeeker is not currently available in the Riid Type dropdo...
RadSeeker is not currently available in the Riid Type dropdown menu. Choose Detective or Identifinder option.
3644 - Click Import File
Click Import File
3732 - 3645 - Open spectrum; Remark:3661
3645 - Open spectrum
Open spectrum
3661 - Locate spectral file previously saved. Select the N42.N42 file (ANSI format)....
Locate spectral file previously saved. Select the N42.N42 file (ANSI format). Click Open.

3733 - 3646 - İletişim kutusu penceresini kapatmak için “OK” (Tamam) düğmesine tıklayın; Remark:3662
3646 - İletişim kutusu penceresini kapatmak için “OK” (Tamam) düğmesine tıklayın
İletişim kutusu penceresini kapatmak için “OK” (Tamam) düğmesine tıklayın
3734 - 3647 - Eki doğrulamak için “RIID Data” (RIID Verisi) sekmesine tıklayın; Remark:3663
3647 - Eki doğrulamak için “RIID Data” (RIID Verisi) sekmesine tıklayın
Eki doğrulamak için “RIID Data” (RIID Verisi) sekmesine tıklayın
3663 - Ekli dosya(lar) bu olaya eklenmiş olan RIID Taramaları altında listelenecektir.
Ekli dosya(lar) bu olaya eklenmiş olan RIID Taramaları altında listelenecektir.

3736 - 3649 - Type a comment; Remark:3665
3649 - Type a comment
Type a comment
3665 - The comment should indicate that a RadSeeker was used to perform identificati...
The comment should indicate that a RadSeeker was used to perform identification.

3737 - 3650 - Click OK; Remark:
3650 - Click OK
Click OK
253 - 242 - Çözülmemiş sorunlar varsa kaydedin ve rapor edin; Remark:
242 - Çözülmemiş sorunlar varsa kaydedin ve rapor edin
Çözülmemiş sorunlar varsa kaydedin ve rapor edin