Last Updated: 05/18/2025 1:35 AM
The following table lists all the components that make up the document.
Routine assessment of the Rapiscan PRM-470.
This procedure may be performed using the Handheld Assessment and Troubleshooting Software (HATS)
None
Prior to arrival, notify operators concerning expected work and duration.
Several revisions: updated description to use HATS, updated pictures for step 1, added pictures for several steps, updated step 2 charger pictures and information, added Efficiency Test in step 5 for future use.
361 - 343 - Document model and serial number; Remark:349
343 - Document model and serial number
Document model and serial number
349 - Model (CG or CGN) and serial number are located on the bottom of the instrume...
Model (CG or CGN) and serial number are located on the bottom of the instrument. Document these on the Rapiscan PRM-470 CG(N) Assessment Form.


312 - 311 - Verificați dacă instrumentul se încarcă; Remark:
311 - Verificați dacă instrumentul se încarcă
Verificați dacă instrumentul se încarcă
260 - 313 - Opriți instrumentul; Remark:
313 - Opriți instrumentul
Opriți instrumentul
316 - 315 - Conectați încărcătorul; Remark:289
315 - Conectați încărcătorul
Conectați încărcătorul
289 - Conectați încărcătorul la instrument și la priza de curent alternativ.
Conectați încărcătorul la instrument și la priza de curent alternativ.


318 - 317 - Observați starea încărcătorului; Remark:290
317 - Observați starea încărcătorului
Observați starea încărcătorului
290 - Acest încărcător prezintă o lumină galbenă intermitentă pe durata înc...
Acest încărcător prezintă o lumină galbenă intermitentă pe durata încărcării.

291 - Acest încărcător prezintă o lumină galbenă continuă pe durata încărc...
Acest încărcător prezintă o lumină galbenă continuă pe durata încărcării.

358 - 344 - Verify parameter settings are correct; Remark:351
344 - Verify parameter settings are correct
Verify parameter settings are correct
351 - NSDD has established standardized PRM-470 parameters. Some instruments have s...
NSDD has established standardized PRM-470 parameters. Some instruments have site-specific values for Sigma.
Perform DET-HHD-RAP-RM03 PRM-470 Settings Verification.
359 - 319 - Perform operational test; Remark:347
319 - Perform operational test
Perform operational test
347 - Perform DET-HHD-RAP-RM01 PRM-470 Operational Test.
Perform DET-HHD-RAP-RM01 PRM-470 Operational Test.
355 - 345 - Perform an efficiency test; Remark:348
345 - Perform an efficiency test
Perform an efficiency test
348 - Perform DET-HHD-RAP-RM05 PRM-470 Efficiency Test.
Perform DET-HHD-RAP-RM05 PRM-470 Efficiency Test.
357 - 356 - Document results on Assessment Form; Remark:352
356 - Document results on Assessment Form
Document results on Assessment Form
352 - Report “OK” or “Changed” for the Settings Verified c...
Report “OK” or “Changed” for the Settings Verified column.
Report “Pass” or “Fail” in the Operational Test column.
Report measured efficiency in the Efficiency Test column.
Use the Comments column to note any change in parameter settings, damage, battery replacements, or issues with the instrument.
354 - 346 - Transmiteți formularul de evaluare; Remark:353
346 - Transmiteți formularul de evaluare
Transmiteți formularul de evaluare
353 - Transmiteți în mod electronic Formularul de evaluare al Pagerului pentru ra...
Transmiteți în mod electronic Formularul de evaluare al Pagerului pentru radiații sau fișierul de evaluare HATS către autoritățile adecvate