Last Updated: 04/25/2025 1:44 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
ORTEC radEAGLET-R 2SG
Device
Published
10/08/2024 1:48 PM
247 - 257 - Prepare instrument; Remark:
Procedure Step
Published
04/11/2025 9:08 PM
257 - Prepare instrument
Instruction
Published
04/11/2025 9:07 PM
10725 - 10724 - Wear safety strap; Remark:10723
Procedure Step
Published
07/19/2024 2:24 PM
10724 - Wear safety strap
Instruction
Published
07/19/2024 2:22 PM
10723 - radEAGLET Wear safety strap
Remark
Published
09/28/2024 8:38 AM
786 - 219 - Verify there are no sources of radiation near instrument; Remark:7
Procedure Step
Published
04/20/2025 6:37 PM
219 - Verify there are no sources of radiation near instrument
Instruction
Published
04/12/2025 4:20 PM
7 - No Radiation symbol
Remark
Published
07/12/2021 1:34 PM
10726 - 10722 - Place instrument next to calibration block; Remark:10720
Procedure Step
Published
07/19/2024 2:30 PM
10722 - Place instrument next to calibration block
Instruction
Published
07/19/2024 2:28 PM
10720 - This is not required for models with an internal Cesium-137 (Cs-137) source. ...
Remark
Published
07/19/2024 2:28 PM
10721 - radEAGLET Next to calibration block
Remark
Published
09/28/2024 10:54 AM
10727 - 220 - Power on instrument; Remark:10718
Procedure Step
Published
07/19/2024 2:44 PM
220 - Power on instrument
Instruction
Published
04/06/2025 7:00 PM
10718 - Hold power button for about 2 seconds.
Remark
Published
07/19/2024 2:35 PM
10719 - radEAGLET Power instrument on
Remark
Published
09/28/2024 10:57 AM
10728 - 612 - Wait for instrument to complete start-up sequence; Remark:10713
Procedure Step
Published
04/13/2025 6:58 PM
612 - Wait for instrument to complete start-up sequence
Instruction
Published
04/13/2025 6:38 PM
10713 - This may take 1-3 minutes.
Remark
Published
07/19/2024 2:45 PM
10714 - radEAGLET Start up instrument stabilizing
Remark
Published
09/26/2024 7:15 PM
10715 - radEAGLET Start up sequence
Remark
Published
09/26/2024 7:14 PM
10729 - 10712 - Verify sufficient battery charge; Remark:10710
Procedure Step
Published
07/19/2024 3:01 PM
10717 - Note : If the screen dims due to inactivity, press any button once to wake up.
Annotation
Published
07/19/2024 2:49 PM
10712 - Verify sufficient battery charge
Instruction
Published
07/19/2024 2:57 PM
10710 - A fully charged battery will last approximately 8 hours. Confirm remaining ba...
Remark
Published
07/19/2024 3:00 PM
10711 - radEAGLET Verify battery charge
Remark
Published
09/28/2024 11:12 AM
10730 - 10709 - Verify instrument is stabilized; Remark:10707
Procedure Step
Published
07/19/2024 3:04 PM
10709 - Verify instrument is stabilized
Instruction
Published
07/19/2024 3:02 PM
10707 - The instrument is stabilized when the icon is green.
Remark
Published
07/19/2024 3:03 PM
10708 - radEAGLET Verify instrument stablized
Remark
Published
09/25/2024 10:09 PM
11051 - 3494 - Collect background measurement; Remark:10705
Procedure Step
Published
09/27/2024 8:51 PM
3494 - Collect background measurement
Instruction
Published
08/27/2024 5:25 PM
10705 - For instructions on performing a background measurement, refer to DET-HHD-ORT...
Remark
Published
04/13/2025 5:28 PM
410 - 7519 - Locate radioactive material; Remark:
Procedure Step
Published
04/13/2025 6:17 PM
7519 - Locate radioactive material
Instruction
Published
04/13/2025 5:47 PM
10696 - 2209 - Verify instrument is in a suitable background radiation area; Remark:10693
Procedure Step
Published
07/19/2024 3:14 PM
2209 - Verify instrument is in a suitable background radiation area
Instruction
Published
06/11/2024 3:31 PM
10693 - The instrument should be located near the secondary inspection area, in simil...
Remark
Published
07/19/2024 3:12 PM
10794 - No Radiation Sources
Remark
Published
09/28/2024 11:01 AM
10697 - 10692 - Enter DETECT mode; Remark:10690
Procedure Step
Published
07/19/2024 3:19 PM
10695 - Note : Left, right, and down arrow Buttons will select screen options. The remainder...
Annotation
Published
07/19/2024 3:14 PM
10692 - Enter DETECT mode
Instruction
Published
07/19/2024 3:16 PM
10690 - Press down arrow to select DETECT.
Remark
Published
07/19/2024 3:16 PM
10691 - radEAGLET Enter DETECT Mode
Remark
Published
09/28/2024 11:40 AM
10698 - 2220 - Wait for measurement to complete; Remark:10688
Procedure Step
Published
07/19/2024 3:23 PM
2220 - Wait for measurement to complete
Instruction
Published
10/22/2020 11:15 AM
10688 - This should take approximately 30 seconds. Instrument is ready when percentage b...
Remark
Published
07/19/2024 3:22 PM
10689 - radEAGLET Wait for measurement to complete
Remark
Published
09/26/2024 7:42 PM
10699 - 408 - Survey close to surface of item; Remark:388
Procedure Step
Published
07/19/2024 3:27 PM
408 - Survey close to surface of item
Instruction
Published
06/10/2021 8:50 PM
388 - Maintain a distance of approximately 5 to 10 cm from surface of item. Do not ...
Remark
Published
06/10/2021 8:49 PM
10687 - radEAGLET Survey close to surface
Remark
Published
09/27/2024 9:01 PM
10700 - 366 - Survey slowly over entire item; Remark:2315
Procedure Step
Published
07/19/2024 4:06 PM
366 - Survey slowly over entire item
Instruction
Published
06/11/2021 9:10 AM
2315 - Move instrument approximately 20 cm per second. Thoroughly survey all accessi...
Remark
Published
11/04/2020 5:09 PM
10686 - radEAGLET Survey slowly
Remark
Published
09/27/2024 9:06 PM
10701 - 367 - Observe instrument response; Remark:10684
Procedure Step
Published
07/19/2024 4:09 PM
367 - Observe instrument response
Instruction
Published
06/11/2021 9:21 AM
10684 - Use audible alerts, numerical values, and moving graph to locate sources of r...
Remark
Published
07/19/2024 4:07 PM
10685 - radEAGLET Observe response
Remark
Published
09/27/2024 9:09 PM
10702 - 10646 - Localize source of radiation; Remark:386
Procedure Step
Published
07/19/2024 4:12 PM
10646 - Localize source of radiation
Instruction
Published
06/14/2024 4:22 PM
386 - Use crosshair technique to localize.
Remark
Published
06/11/2021 9:20 AM
10683 - radEAGLET Localize source
Remark
Published
09/27/2024 9:11 PM
405 - 368 - Mark point(s) of interest; Remark:4277
Procedure Step
Published
04/20/2025 5:44 PM
368 - Mark point(s) of interest
Instruction
Published
06/11/2021 9:23 AM
4277 - Place a marker (tape, pencil, etc.) on points exhibiting elevated radiation. ...
Remark
Published
04/20/2025 5:37 PM
10704 - 10680 - Exit DETECT mode; Remark:10678
Procedure Step
Published
07/24/2024 1:36 PM
10680 - Exit DETECT mode
Instruction
Published
07/19/2024 4:18 PM
10678 - Select EXIT
Remark
Published
07/19/2024 4:18 PM
10679 - radEAGLET Selet EXIT
Remark
Published
09/27/2024 9:20 PM
10677 - 856 - Identify Isotopes; Remark:
Procedure Step
Published
07/19/2024 4:20 PM
856 - Identify Isotopes
Instruction
Published
07/23/2021 9:20 PM
10674 - 2218 - Place instrument close to measurement location; Remark:2325
Procedure Step
Published
07/19/2024 4:24 PM
2218 - Place instrument close to measurement location
Instruction
Published
04/06/2021 5:15 PM
2325 - The instrument should be as close as possible without making contact.
Remark
Published
07/23/2021 10:42 PM
10673 - radEAGLET Instrument close to location
Remark
Published
09/27/2024 9:22 PM
10943 - 10672 - Verify instrument is in dose rate mode; Remark:10942
Procedure Step
Published
07/29/2024 10:21 AM
10672 - Verify instrument is in dose rate mode
Instruction
Published
07/19/2024 4:25 PM
10942 - radEAGLET Verify instrument is in dose rate mode
Remark
Published
09/27/2024 9:28 PM
10676 - 859 - Start identification measurement; Remark:10665
Procedure Step
Published
07/19/2024 4:32 PM
859 - Start identification measurement
Instruction
Published
10/26/2020 7:00 PM
10665 - Select EASY ID
Remark
Published
07/19/2024 4:28 PM
10666 - radEAGLET Select EASY ID
Remark
Published
10/01/2024 5:36 PM
10667 - Highlight Unknown
Remark
Published
07/19/2024 4:29 PM
10668 - radEAGLET Highlight Unknown
Remark
Published
10/01/2024 5:38 PM
10669 - Choose SELECT
Remark
Published
07/19/2024 4:31 PM
10670 - radEAGLET Unknown choose SELECT
Remark
Published
10/01/2024 5:41 PM
10739 - 2220 - Wait for measurement to complete; Remark:10737
Procedure Step
Published
07/20/2024 7:37 PM
10737 - The screen might prompt the operator to move the instrument away or towards t...
Remark
Published
07/20/2024 7:34 PM
10738 - radEAGLET Wait for measurement to complete
Remark
Published
07/23/2024 6:16 PM
10740 - 2221 - Observe identification results; Remark:10735
Procedure Step
Published
07/20/2024 7:54 PM
2221 - Observe identification results
Instruction
Published
04/06/2021 5:20 PM
10735 - Identification results include: 1) identification confidence (1-10)
Remark
Published
07/20/2024 7:42 PM
10736 - radEAGLET Identification Results
Remark
Published
07/24/2024 11:35 AM
10750 - 10749 - Exit EASY ID mode; Remark:10678
Procedure Step
Published
07/20/2024 8:27 PM
10749 - Exit EASY ID mode
Instruction
Published
07/20/2024 8:24 PM
10748 - radEAGLET Select EXIT
Remark
Published
07/23/2024 5:57 PM
399 - 375 - Document results; Remark:394
Procedure Step
Published
06/11/2021 9:46 AM
375 - Document results
Instruction
Published
06/11/2021 9:37 AM
394 - Document results per Standard Operating Procedures.
Remark
Published
06/11/2021 9:36 AM
2248 - 313 - Power off instrument; Remark:10741
Procedure Step
Published
10/22/2020 12:22 PM
313 - Power off instrument
Instruction
Published
07/23/2021 2:41 PM
10741 - Select MENU
Remark
Published
07/20/2024 8:44 PM
10742 - radEAGLET Select MENU power off
Remark
Published
07/23/2024 6:13 PM
10743 - Highlight Shutdown
Remark
Published
07/20/2024 8:46 PM
10744 - radEAGLET Highlight Shutdown
Remark
Published
07/23/2024 5:59 PM
10745 - radEAGLET Choose Select for Shutdown
Remark
Published
07/23/2024 5:58 PM
10746 - Select OK
Remark
Published
07/20/2024 8:50 PM
10747 - radEAGLET Select OK
Remark
Published
07/23/2024 5:57 PM
10792 - 2370 - Connect to charger; Remark:10787
Procedure Step
Published
07/21/2024 12:40 PM
2370 - Connect to charger
Instruction
Published
04/06/2021 5:31 PM
10787 - The instrument has a wall charger and an automobile charger.
Remark
Published
07/21/2024 12:34 PM
10788 - radEAGLET Wall Charger and Charging Port
Remark
Published
07/23/2024 5:55 PM
10793 -
Remark
Published
07/21/2024 12:43 PM
10789 - Align the red dash with the top of the charging port.
Remark
Published
07/21/2024 12:36 PM
10790 - radEAGLET Align red dash charging port
Remark
Published
07/23/2024 5:54 PM
10791 - radEAGLET Align red dash charging port 2
Remark
Published
07/23/2024 5:41 PM
Operator Procedure
Document Type
Published
03/02/2020 3:31 PM
Note
Annotation Type
Published
03/02/2020 3:25 PM
None
Tools
Published
05/06/2020 9:50 PM
radEAGLET Wear safety strap
Image
Published
07/19/2024 4:32 PM
No Radiation Symbol
Image
Published
08/13/2024 2:56 PM
radEAGLET Next to calibration block
Image
Published
07/19/2024 4:32 PM
radEAGLET Power instrument on
Image
Published
07/19/2024 4:32 PM
radEAGLET Start up instrument stabilizing
Image
Published
07/19/2024 4:32 PM
radEAGLET start up sequence
Image
Published
07/19/2024 4:32 PM
radEAGLET Verify battery charge
Image
Published
07/19/2024 4:32 PM
radEAGLET Verify instrument stabilized
Image
Published
07/19/2024 4:32 PM
No Radiation Sources
Image
Published
07/21/2024 2:10 PM
RadEAGLET Enter DETECT mode_V2.png
Image
Published
07/20/2024 1:49 PM
radEAGLET Wait for measurement to complete
Image
Published
07/19/2024 4:32 PM
radEAGLET Survey close to surface
Image
Published
07/19/2024 4:32 PM
radEAGLET Survey slowly
Image
Published
07/19/2024 4:32 PM
radEAGLET Observe response
Image
Published
07/19/2024 4:32 PM
radEAGLET Localize source
Image
Published
07/19/2024 4:32 PM
Mark_Source_Location_Trefoil
Image
Published
02/19/2023 10:54 AM
radEAGLET Select EXIT DETECT mode
Image
Published
07/25/2024 9:20 PM
radEAGLET Instrument close to location
Image
Published
07/19/2024 4:32 PM
radEAGLET Verify instrument is in dose rate mode
Image
Published
07/19/2024 4:32 PM
radEAGLET Select EASY ID
Image
Published
07/19/2024 4:32 PM
radEAGLET Highlight Unknown
Image
Published
07/19/2024 4:32 PM
radEAGLET Unknown choose SELECT
Image
Published
07/19/2024 4:32 PM
radEAGLET Wait for measurement to complete
Image
Published
07/20/2024 7:54 PM
radEAGLET Identification Results
Image
Published
07/20/2024 7:54 PM
radEAGLET Select EXIT
Image
Published
07/20/2024 8:51 PM
radEAGLET Select MENU
Image
Published
07/25/2024 8:34 PM
radEAGLET Highlight Shutdown
Image
Published
07/20/2024 8:51 PM
radEAGLET Choose Select for Shutdown
Image
Published
07/20/2024 8:51 PM
radEAGLET Select OK
Image
Published
07/20/2024 8:51 PM
radEAGLET Wall charger
Image
Published
07/21/2024 12:40 PM
radEAGLET Charging port
Image
Published
07/21/2024 12:40 PM
radEAGLET Align red dash charging port
Image
Published
07/21/2024 12:40 PM
radEAGLET Align red dash charging port_2
Image
Published
07/21/2024 12:40 PM
DET-HHD-ORT-RET-OP01

Search for and identify radioactive material.

Equipment Hierarchy
ORTEC radEAGLET-R 2SG
Technician Level
Duration
Tools Required
None
Materials Required
None
Originators
Brian Tucker
Originating Organization
Pacific Northwest National Laboratory
Approver
James Kitchen
Date of Origin
Version
0.00
Step 1

10729 - 10712 - Verify sufficient battery charge; Remark:10710

Step 00
Step 2
Main Step
Step 3

10696 - 2209 - Verify instrument is in a suitable background radiation area; Remark:10693

Step 00
Step 4
Step 5
Main Step
Document Type
Operator Procedure
Percent Complete
100.00
Percent Complete W/Media
100.00