Last Updated: 04/24/2025 1:43 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Rapiscan PM-700 Pedestrian Monitor
Device
Published
06/20/2024 11:38 AM
Rapiscan VM-250 Vehicle Monitor
Device
Published
10/14/2024 9:50 AM
Rapiscan TM-850 Rail Monitor
Device
Published
09/18/2024 10:28 AM
7264 - 1401 - Establish Initial Conditions; Remark:
Procedure Step
Published
04/27/2023 7:00 PM
1401 - Establish Initial Conditions
Instruction
Published
09/30/2022 3:14 PM
7268 - 7231 - Close lane; Remark:7233
Procedure Step
Published
04/27/2023 7:01 PM
9053 - Warning : Traffic should temporarily be rerouted or halted during conduction of this pr...
Annotation
Published
09/27/2023 9:09 AM
7231 - Close lane
Instruction
Published
04/18/2023 1:00 PM
7233 - Use orange safety (traffic control) cones to setup barriers. Practice establi...
Remark
Published
04/24/2023 12:18 PM
7269 - 7232 - Open RPM door; Remark:7234
Procedure Step
Published
04/27/2023 7:02 PM
7232 - Open RPM door
Instruction
Published
04/18/2023 1:02 PM
7234 - Open all doors needed to access components.
Remark
Published
04/19/2025 7:48 PM
7270 - 7235 - Power off RPM; Remark:7236
Procedure Step
Published
09/01/2023 7:57 PM
7235 - Power off RPM
Instruction
Published
04/24/2023 12:30 PM
7236 - Move LD-260 switch to OFF position. The PWR ON
Remark
Published
04/27/2023 4:25 PM
7271 - 7237 - Uninstall Faulty LD-260; Remark:
Procedure Step
Published
04/27/2023 7:05 PM
7237 - Uninstall Faulty LD-260
Instruction
Published
04/24/2023 1:09 PM
7272 - 7238 - Disconnect three (3) connectors; Remark:7239
Procedure Step
Published
04/27/2023 7:06 PM
5291 - Note : It is good practice to verify all cables and connectors are labeled prior to ...
Annotation
Published
10/24/2022 8:35 AM
7238 - Disconnect three (3) connectors
Instruction
Published
04/24/2023 12:38 PM
7239 - Needle nose pliers can be used to remove connectors.
Remark
Published
05/10/2023 3:08 PM
7273 - 7240 - Remove two (2) mounting screw; Remark:7241
Procedure Step
Published
04/27/2023 4:09 PM
7240 - Remove two (2) mounting screws
Instruction
Published
04/05/2025 2:39 PM
7241 - Use medium Phillips (PH2) screwdriver. Retain screws.
Remark
Published
05/10/2023 3:09 PM
7274 - 7242 - Remove faulty LD-260; Remark:
Procedure Step
Published
04/27/2023 4:09 PM
7242 - Remove faulty LD-260
Instruction
Published
05/10/2023 3:10 PM
3397 - 3395 - Label faulty component; Remark:3396
Procedure Step
Published
07/21/2024 6:59 AM
3395 - Label faulty component
Instruction
Published
08/07/2021 11:07 AM
3396 - Use tag or tape. Include date of removal, description of failure symptoms, co...
Remark
Published
08/09/2021 11:35 AM
7276 - 7245 - Install New LD-260; Remark:
Procedure Step
Published
04/27/2023 4:11 PM
7245 - Install New LD-260
Instruction
Published
05/10/2023 3:11 PM
7277 - 7246 - Mount new LD-260; Remark:7247
Procedure Step
Published
04/27/2023 7:07 PM
7246 - Mount new LD-260
Instruction
Published
05/10/2023 3:12 PM
7247 - Use retained screws. Use medium Phillips (PH2) screwdriver.
Remark
Published
05/10/2023 3:12 PM
7278 - 7248 - Reconnect three (3) connectors; Remark:7411
Procedure Step
Published
05/08/2023 8:31 AM
7263 - Caution : Correct placement of connectors and wiring is critical to proper operation.
Annotation
Published
04/24/2023 2:32 PM
7248 - Reconnect three (3) connectors
Instruction
Published
05/10/2023 3:13 PM
7411 - Reconnect three (3) connectors
Remark
Published
05/08/2023 8:30 AM
7279 - 7249 - Return equipment to normal operating condition; Remark:
Procedure Step
Published
04/27/2023 4:13 PM
7249 - Return equipment to normal operating condition
Instruction
Published
04/08/2025 3:22 PM
7280 - 7250 - Power on RPM; Remark:7251
Procedure Step
Published
04/27/2023 4:14 PM
7250 - Power on RPM
Instruction
Published
05/01/2023 8:31 AM
7251 - Move LD-260 switch to ON position. The LED PWR ON
Remark
Published
05/10/2023 3:14 PM
7281 - 7252 - Verify RPM start-up; Remark:7253
Procedure Step
Published
04/20/2025 3:26 PM
7252 - Verify RPM start-up
Instruction
Published
04/27/2023 2:23 PM
7253 - RPM will perform a power on self-test (POST) and collect a background radiati...
Remark
Published
05/10/2023 3:14 PM
7282 - 7254 - Confirm network connection; Remark:7255
Procedure Step
Published
04/27/2023 4:15 PM
7254 - Confirm network connection
Instruction
Published
04/27/2023 2:22 PM
7255 - Contact operators to confirm communications have been reestablished between RPM ...
Remark
Published
05/10/2023 3:15 PM
7283 - 7256 - Close and lock all RPM doors; Remark:
Procedure Step
Published
09/01/2023 11:45 PM
7256 - Close and lock all RPM doors
Instruction
Published
04/27/2023 2:21 PM
7842 - 7820 - Inform system operators upon completion of maintenance action; Remark:
Procedure Step
Published
07/07/2023 11:15 PM
7820 - Inform system operators upon completion of maintenance action
Instruction
Published
07/07/2023 10:02 PM
322 - 321 - Document maintenance actions; Remark:
Procedure Step
Published
06/17/2021 9:49 AM
321 - Document maintenance actions
Instruction
Published
04/21/2025 11:19 AM
2869 - 2585 - Document maintenance performed; Remark:2866
Procedure Step
Published
06/18/2021 5:58 PM
2585 - Document maintenance performed
Instruction
Published
07/09/2021 12:15 PM
2866 - Record observations, times, and results for the maintenance report.
Remark
Published
04/21/2025 11:39 AM
4706 - 4705 - Submit report; Remark:4864
Procedure Step
Published
06/29/2022 9:50 AM
4705 - Submit report
Instruction
Published
06/29/2022 9:50 AM
4864 - As specified by management or contractual obligations.
Remark
Published
07/28/2022 1:36 PM
Corrective Maintenance Procedure
Document Type
Published
03/02/2020 3:32 PM
Instrument is not functioning correctly
Frequency
Published
12/19/2022 5:52 PM
Warning
Annotation Type
Published
03/02/2020 3:25 PM
Note
Annotation Type
Published
03/02/2020 3:25 PM
Caution
Annotation Type
Published
03/02/2020 3:24 PM
Technician 2
Skill Level
Published
04/09/2020 1:17 AM
Keys to access RPM
Replacement Parts
Published
04/27/2023 6:56 PM
Medium Phillips (PH2) screwdriver
Tools
Published
04/24/2020 4:40 PM
Needle nose pliers
Tools
Published
05/06/2020 4:10 PM
Orange/yellow safety vest
Replacement Parts
Published
04/27/2023 6:56 PM
Safety shoes
Replacement Parts
Published
04/27/2023 6:56 PM
Gloves
Replacement Parts
Published
05/10/2023 3:28 PM
Protective headwear: glasses, hard hat
Replacement Parts
Published
05/10/2023 3:31 PM
Orange traffic cones
Replacement Parts
Published
04/27/2023 6:56 PM
LD-260 Disconnect Switch Power Off
Image
Published
04/24/2023 12:49 PM
LD-260 Disconnect Switch Connector Removal
Image
Published
04/24/2023 12:57 PM
LD-260 Disconnect Switch Screw Locations
Image
Published
04/24/2023 1:03 PM
LD-260 Disconnect Switch Connector Install
Image
Published
04/24/2023 1:19 PM
LD-260 Disconnect Switch Power On
Image
Published
05/04/2023 3:37 PM
DET-RPM-RAP-CM06

Replace the LD-260 load disconnect on the radiation portal monitor (RPM).

Equipment Hierarchy
Rapiscan PM-700 Pedestrian Monitor
Rapiscan VM-250 Vehicle Monitor
Rapiscan TM-850 Rail Monitor
Frequency
Instrument is not functioning correctly
Technician Level
Technician Level
Technician 2
x 1
Duration
Length of time
15
Tools Required
Keys to access RPM
Medium Phillips (PH2) screwdriver
Needle nose pliers
Orange/yellow safety vest
Safety shoes
Gloves
Protective headwear: glasses, hard hat
Orange traffic cones
Materials Required
LD-260 Load Disconnect (Rapiscan Part #8453B)
Originators
Craig Stinson
David Alexander
Brian Tucker
Originating Organization
ORNL; PNNL
Approver
Cody Hostick
Safety Concerns
Traffic
Final Documentation
Corrective Maintenance Report
Departmental Coordination

Prior to arrival, notify operators concerning expected work, duration, and anticipated alarms and fault indications.

Date of Origin
Version
0.00
Preparation
Step 1

7268 - 7231 - Close lane; Remark:7233

Step 00
Operation
Step 2
Operation
Step 4
Document Type
Corrective Maintenance Procedure
Percent Complete
100.00
Percent Complete W/Media
100.00