Last Updated: 04/24/2025 1:43 AM
The following table lists all the components that make up the document.
Replace a faulty BEA IXIO-DT1 occupancy sensor. This procedure can also be used to replace a faulty BEA Wizard G3 occupancy sensor.
Prior to arrival, notify operators concerning expected work, duration, and anticipated alarms and fault indications.
7478 - 1401 - Establish Initial Conditions; Remark:
1401 - Establish Initial Conditions
Establish Initial Conditions
7452 - 7231 - Close lane; Remark:7415
7231 - Close lane
Close lane
7415 - Re-route pedestrian traffic.
Re-route pedestrian traffic.
7453 - 7232 - Open RPM door; Remark:7267
7232 - Open RPM door
Open RPM door
7267 - Open all doors needed to access components.
Open all doors needed to access components.
7454 - 7290 - Disable tamper switches; Remark:7416
7290 - Disable tamper switches
Disable tamper switches
7416 - Use a magnet to disable tamper switches for all open doors. Use adhesive tape...
Use a magnet to disable tamper switches for all open doors. Use adhesive tape to disable older mechanical switches.


7270 - 7235 - Power off RPM; Remark:7236
7235 - Power off RPM
Power off RPM
7236 - Move LD-260 switch to OFF position. The PWR ON
Move LD-260 switch to OFF position. The PWR ON LED will turn off.

7479 - 7417 - Prepare New Occupancy Sensor; Remark:
7417 - Prepare New Occupancy Sensor
Prepare New Occupancy Sensor
7456 - 7418 - Remove cover from new occupancy sensor; Remark:7419
7418 - Remove cover from new occupancy sensor
Remove cover from new occupancy sensor
7419 - Use a slotted screwdriver to pry the cover off from the side.
Use a slotted screwdriver to pry the cover off from the side.

7457 - 7420 - Verify narrow field radar antenna is installed; Remark:7421
7420 - Verify narrow field radar antenna is installed
Verify narrow field radar antenna is installed
7421 - The IXIO-DT1 should come with the narrow field antenna installed.
The IXIO-DT1 should come with the narrow field antenna installed.

8901 - If needed, the antenna can be changed. Remove cover. Install narrow field ant...
If needed, the antenna can be changed. Remove cover. Install narrow field antenna stored in slot behind antenna mount. Replace cover.


7480 - 7422 - Uninstall Faulty Occupancy Sensor; Remark:
7422 - Uninstall Faulty Occupancy Sensor
Uninstall Faulty Occupancy Sensor
7458 - 7423 - Remove Cover; Remark:7424
7423 - Remove Cover
Remove Cover
7424 - If needed, use a sharp utility knife to cut sealant around edges of sensor. A...
If needed, use a sharp utility knife to cut sealant around edges of sensor. A slotted screwdriver is needed to remove the cover.

7459 - 7425 - Disconnect wire connector; Remark:7426
7425 - Disconnect wire connector
Disconnect wire connector
7426 - The wire connector is located on the right side of existing sensor.
The wire connector is located on the right side of existing sensor.

7460 - 7427 - Loosen two (2) mounting screws; Remark:7428
7429 - Note : Some existing occupancy sensors are installed using screws and nuts, ...
- Some existing occupancy sensors are installed using screws and nuts, others are installed using self tapping screws.
- Removal and replacement only requires mounting screws to be loose, not completely removed.
7427 - Loosen two (2) mounting screws
Loosen two (2) mounting screws
7428 - Use a medium Phillips (PH2) screwdriver. If screws and nuts were used, an adj...
Use a medium Phillips (PH2) screwdriver. If screws and nuts were used, an adjustable wrench may be needed.

7461 - 7430 - Remove faulty occupancy sensor; Remark:7431
7430 - Remove faulty occupancy sensor
Remove faulty occupancy sensor
7431 - If a Wizard G3 sensor is being removed, push up on both sides to free the sen...
If a Wizard G3 sensor is being removed, push up on both sides to free the sensor from the mounting screws. If an IXIO-DT1 sensor is being removed, push up on right side and slide sensor to the right.


3397 - 3395 - Label faulty component; Remark:3396
3395 - Label faulty component
Label faulty component
3396 - Use tag or tape. Include date of removal, description of failure symptoms, co...
Use tag or tape. Include date of removal, description of failure symptoms, country, site, and lane number. Dispose per Nuclear Smuggling Detection and Deterrence (NSDD) guidance or contractual requirements.
7481 - 7432 - Install new occupancy sensor; Remark:
7432 - Install new occupancy sensor
Install new occupancy sensor
7463 - 7433 - Mount new sensor; Remark:7434
7433 - Mount new sensor
Mount new sensor
7434 - First, slide left side onto mounting screw.
First, slide left side onto mounting screw.

9206 - Then, place right side over mounting screw and push down.
Then, place right side over mounting screw and push down.

7464 - 7435 - Tighten two (2) mounting screws; Remark:7436
7435 - Tighten two (2) mounting screws
Tighten two (2) mounting screws
7436 - Use medium Phillips (PH2) screwdriver. Take care not to overtighten.
Use medium Phillips (PH2) screwdriver. Take care not to overtighten.

7482 - 7437 - Route wiring through clamp and connect; Remark:7488
7437 - Route wiring through clamp and connect
Route wiring through clamp and connect
7488 - Clamp and Connect

7465 - 7439 - Adjust angle of the radar antenna; Remark:7438
7439 - Adjust angle of the radar antenna
Adjust angle of the radar antenna
7438 - The angle is adjusted by manually rotating the antenna up or down. The defaul...
The angle is adjusted by manually rotating the antenna up or down. The default angle is approximately 15 degrees.


7279 - 7249 - Return equipment to normal operating condition; Remark:
7249 - Return equipment to normal operating condition
Return equipment to normal operating condition
7466 - 7440 - Hold door open; Remark:7441
7440 - Hold door open
Hold door open
7441 - Do not move door. Door must remain stationary to prevent occupancy.
Do not move door. Door must remain stationary to prevent occupancy.
7280 - 7250 - Power on RPM; Remark:7251
7250 - Power on RPM
Power on RPM
7251 - Move LD-260 switch to ON position. The LED PWR ON
Move LD-260 switch to ON position. The LED PWR ON will illuminate.

7468 - 7304 - Confirm RPM has restarted correctly; Remark:7487
7304 - Confirm RPM has restarted correctly
Confirm RPM has restarted correctly
7487 - The SC-770 controller will display "OK" following Power On Self-Test (POST) a...
The SC-770 controller will display "OK" following Power On Self-Test (POST) and background measurement.
7282 - 7254 - Confirm network connection; Remark:7255
7254 - Confirm network connection
Confirm network connection
7255 - Contact operators to confirm communications have been reestablished between RPM ...
7470 - 7442 - Generate occupancy; Remark:7443
7442 - Generate occupancy
Generate occupancy
7443 - Create motion in front of occupancy sensor. While holding the door open and s...
Create motion in front of occupancy sensor. While holding the door open and still, wave a hand or walk in front of the sensor.
7471 - 7444 - Verify occupancy sensor functionality; Remark:7445
7444 - Verify occupancy sensor functionality
Verify occupancy sensor functionality
7445 - IXIO-DT1 green sensor light will illuminate.
IXIO-DT1 green sensor light will illuminate.

8973 - Left latch on the LCD screen will indicate a “closed” circuit.
Left latch on the LCD screen will indicate a “closed” circuit.

8974 - SC-770 status will read “OCCUPIED”.
SC-770 status will read “OCCUPIED”.

7472 - 7446 - Install sensor cover; Remark:7447
7446 - Install sensor cover
Install sensor cover
7447 - The cover should snap into place.
The cover should snap into place.

7473 - 7448 - If needed, apply sealant; Remark:7449
7448 - If needed, apply sealant
If needed, apply sealant
7449 - If used outdoors, sealant should be applied to top and sides of cover. Do not...
If used outdoors, sealant should be applied to top and sides of cover. Do not apply sealant along bottom of cover. Remove excess silicone with mineral spirits and rags.

7474 - 7310 - Enable tamper switches; Remark:7451
7310 - Enable tamper switches
Enable tamper switches
7451 - Remove magnets and/or adhesive tape from door tamper switches.
Remove magnets and/or adhesive tape from door tamper switches.

7283 - 7256 - Close and lock all RPM doors; Remark:
7256 - Close and lock all RPM doors
Close and lock all RPM doors
7842 - 7820 - Inform system operators upon completion of maintenance action; Remark:
7820 - Inform system operators upon completion of maintenance action
Inform system operators upon completion of maintenance action
322 - 321 - Document maintenance actions; Remark:
321 - Document maintenance actions
Document maintenance actions
2869 - 2585 - Document maintenance performed; Remark:2866
2585 - Document maintenance performed
Document maintenance performed
2866 - Record observations, times, and results for the maintenance report.
Record observations, times, and results for the maintenance report.
4706 - 4705 - Submit report; Remark:4864
4705 - Submit report
Submit report
4864 - As specified by management or contractual obligations.