Last Updated: 04/24/2025 1:45 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Rapiscan VM-250 Vehicle Monitor
Device
Published
10/14/2024 9:50 AM
Rapiscan PM-700 Pedestrian Monitor
Device
Published
06/20/2024 11:38 AM
Rapiscan TM-850 Rail Monitor
Device
Published
09/18/2024 10:28 AM
Rapiscan CM-267 Conveyor Monitor
Device
Published
06/27/2024 1:02 PM
7621 - 1401 - Establish Initial Conditions; Remark:
Procedure Step
Published
06/29/2023 5:37 PM
1401 - Establish Initial Conditions
Instruction
Published
09/30/2022 3:14 PM
7268 - 7231 - Close lane; Remark:7233
Procedure Step
Published
04/27/2023 7:01 PM
9053 - Warning : Traffic should temporarily be rerouted or halted during conduction of this pr...
Annotation
Published
09/27/2023 9:09 AM
7231 - Close lane
Instruction
Published
04/18/2023 1:00 PM
7233 - Use orange safety (traffic control) cones to setup barriers. Practice establi...
Remark
Published
04/24/2023 12:18 PM
7269 - 7232 - Open RPM door; Remark:7234
Procedure Step
Published
04/27/2023 7:02 PM
7232 - Open RPM door
Instruction
Published
04/18/2023 1:02 PM
7234 - Open all doors needed to access components.
Remark
Published
04/19/2025 7:48 PM
8221 - 7676 - Brief system operators on expected work, duration, anticipated alarms, and fa...; Remark:
Procedure Step
Published
09/01/2023 9:26 PM
7676 - Brief system operators on expected work, duration, anticipated alarms, and fa...
Instruction
Published
07/01/2023 11:39 PM
9632 - 9609 - Power off AC circuit breaker; Remark:9610
Procedure Step
Published
10/11/2023 3:25 PM
9607 - Warning : 110/240 VAC is present at circuit breaker and at the AC line filter.
Annotation
Published
04/13/2025 6:03 PM
9608 - Note : Normally, the OFF position will be when the circuit breaker ...
Annotation
Published
10/11/2023 2:20 PM
9609 - Power off AC circuit breaker
Instruction
Published
10/11/2023 2:21 PM
9610 - The AC circuit breaker is located at the bottom of the control pillar. ...
Remark
Published
04/13/2025 6:03 PM
9633 - 9611 - Uninstall AC Line Filter; Remark:
Procedure Step
Published
10/11/2023 3:26 PM
9611 - Uninstall AC Line Filter
Instruction
Published
10/11/2023 2:30 PM
9634 - 9612 - Confirm no AC voltage is present; Remark:9613
Procedure Step
Published
04/13/2025 6:15 PM
9612 - Confirm no AC voltage is present
Instruction
Published
04/13/2025 6:02 PM
9613 - Using a digital multimeter, place the negative (-) lead on the mounting screw...
Remark
Published
10/11/2023 2:36 PM
9635 - 9615 - Measure each black wire connection; Remark:9616
Procedure Step
Published
10/11/2023 3:27 PM
9614 - Warning : DO NOT proceed if voltage is present at either wire location...
Annotation
Published
10/11/2023 2:37 PM
9615 - Measure each black wire connection
Instruction
Published
10/11/2023 2:40 PM
9616 - Using a digital multimeter, place the positive (+) lead on each of the mounti...
Remark
Published
10/11/2023 2:44 PM
9636 - 9617 - Measure each white wire connection; Remark:9618
Procedure Step
Published
10/11/2023 3:28 PM
9617 - Measure each white wire connection
Instruction
Published
10/11/2023 2:45 PM
9618 - Using a digital multimeter, place the positive (+) lead on each of the mounti...
Remark
Published
10/11/2023 2:49 PM
9637 - 9619 - Disconnect all wiring; Remark:9620
Procedure Step
Published
10/11/2023 3:29 PM
7352 - Note : It is good practice to verify all cables and connectors are labeled prior to ...
Annotation
Published
05/03/2023 11:27 AM
9619 - Disconnect all wiring
Instruction
Published
10/11/2023 2:51 PM
9620 - Using a small Phillips screwdriver, disconnect all the wires attached to the ...
Remark
Published
10/11/2023 2:52 PM
9638 - 9621 - Remove AC line filter; Remark:9622
Procedure Step
Published
10/11/2023 3:30 PM
9621 - Remove AC line filter
Instruction
Published
10/11/2023 2:52 PM
9622 - Remove two M4 mounting screws and washers. Retain hardware.
Remark
Published
10/11/2023 2:58 PM
3397 - 3395 - Label faulty component; Remark:3396
Procedure Step
Published
07/21/2024 6:59 AM
3395 - Label faulty component
Instruction
Published
08/07/2021 11:07 AM
3396 - Use tag or tape. Include date of removal, description of failure symptoms, co...
Remark
Published
08/09/2021 11:35 AM
9639 - 9623 - Install New AC Line Filter; Remark:
Procedure Step
Published
10/11/2023 3:30 PM
9623 - Install New AC Line Filter
Instruction
Published
10/11/2023 3:01 PM
9640 - 9624 - Mount new AC line filter; Remark:9625
Procedure Step
Published
10/11/2023 3:31 PM
7263 - Caution : Correct placement of connectors and wiring is critical to proper operation.
Annotation
Published
04/24/2023 2:32 PM
9624 - Mount new AC line filter
Instruction
Published
10/11/2023 3:01 PM
9625 - Reuse retained M4 screws and internal washers. Remember to mount the ground w...
Remark
Published
10/11/2023 3:04 PM
9641 - 9626 - Reconnect AC line filter wiring; Remark:9627
Procedure Step
Published
10/11/2023 3:32 PM
9626 - Reconnect AC line filter wiring
Instruction
Published
10/11/2023 3:07 PM
9627 - Make sure the load wire (+) is accross from the line wire (+).
Remark
Published
10/11/2023 3:09 PM
7279 - 7249 - Return equipment to normal operating condition; Remark:
Procedure Step
Published
04/27/2023 4:13 PM
7249 - Return equipment to normal operating condition
Instruction
Published
04/08/2025 3:22 PM
9642 - 9628 - Power on AC circuit breaker; Remark:9629
Procedure Step
Published
10/11/2023 3:33 PM
9628 - Power on AC circuit breaker
Instruction
Published
10/11/2023 3:12 PM
9629 - AC Circuit Breaker On
Remark
Published
10/11/2023 3:16 PM
9643 - 9630 - Verify AC line filter voltage; Remark:9631
Procedure Step
Published
10/11/2023 3:33 PM
9630 - Verify AC line filter voltage
Instruction
Published
10/11/2023 3:18 PM
9631 - Voltage should be present at both the input and output. 110-240 VAC will be p...
Remark
Published
10/11/2023 3:21 PM
7280 - 7250 - Power on RPM; Remark:7251
Procedure Step
Published
04/27/2023 4:14 PM
7250 - Power on RPM
Instruction
Published
05/01/2023 8:31 AM
7251 - Move LD-260 switch to ON position. The LED PWR ON
Remark
Published
05/10/2023 3:14 PM
7281 - 7252 - Verify RPM start-up; Remark:7253
Procedure Step
Published
04/20/2025 3:26 PM
7252 - Verify RPM start-up
Instruction
Published
04/27/2023 2:23 PM
7253 - RPM will perform a power on self-test (POST) and collect a background radiati...
Remark
Published
05/10/2023 3:14 PM
7282 - 7254 - Confirm network connection; Remark:7255
Procedure Step
Published
04/27/2023 4:15 PM
7254 - Confirm network connection
Instruction
Published
04/27/2023 2:22 PM
7255 - Contact operators to confirm communications have been reestablished between RPM ...
Remark
Published
05/10/2023 3:15 PM
7283 - 7256 - Close and lock all RPM doors; Remark:
Procedure Step
Published
09/01/2023 11:45 PM
7256 - Close and lock all RPM doors
Instruction
Published
04/27/2023 2:21 PM
7842 - 7820 - Inform system operators upon completion of maintenance action; Remark:
Procedure Step
Published
07/07/2023 11:15 PM
7820 - Inform system operators upon completion of maintenance action
Instruction
Published
07/07/2023 10:02 PM
322 - 321 - Document maintenance actions; Remark:
Procedure Step
Published
06/17/2021 9:49 AM
321 - Document maintenance actions
Instruction
Published
04/21/2025 11:19 AM
2869 - 2585 - Document maintenance performed; Remark:2866
Procedure Step
Published
06/18/2021 5:58 PM
2585 - Document maintenance performed
Instruction
Published
07/09/2021 12:15 PM
2866 - Record observations, times, and results for the maintenance report.
Remark
Published
04/21/2025 11:39 AM
4706 - 4705 - Submit report; Remark:4864
Procedure Step
Published
06/29/2022 9:50 AM
4705 - Submit report
Instruction
Published
06/29/2022 9:50 AM
4864 - As specified by management or contractual obligations.
Remark
Published
07/28/2022 1:36 PM
Corrective Maintenance Procedure
Document Type
Published
03/02/2020 3:32 PM
Upon failure of AC line filter
Frequency
Published
10/11/2023 3:49 PM
Warning
Annotation Type
Published
03/02/2020 3:25 PM
Note
Annotation Type
Published
03/02/2020 3:25 PM
Caution
Annotation Type
Published
03/02/2020 3:24 PM
Technician 2
Skill Level
Published
04/09/2020 1:17 AM
Technician 1
Skill Level
Published
05/14/2020 2:56 PM
Small Phillips (PH1) screwdriver
Tools
Published
05/14/2020 2:48 PM
Small slotted (flathead) screwdriver
Tools
Published
09/11/2020 11:23 AM
Digital multimeter DMM
Replacement Parts
Published
06/29/2023 5:46 PM
Orange/yellow safety vest
Replacement Parts
Published
04/27/2023 6:56 PM
Safety shoes
Replacement Parts
Published
04/27/2023 6:56 PM
Safety glasses if required
Replacement Parts
Published
06/20/2023 4:47 PM
Ladder; 2 meters, 6 feet tall; non-conducting if required
Replacement Parts
Published
07/02/2023 4:48 PM
Orange traffic cones
Replacement Parts
Published
04/27/2023 6:56 PM
AC Line Ground Wire
Image
Published
10/11/2023 2:33 PM
AC Line Filter Black Wire
Image
Published
10/11/2023 2:42 PM
AC White Line Filter
Image
Published
10/11/2023 2:48 PM
AC Line Filter Mounts
Image
Published
10/11/2023 2:57 PM
AC Line Filter Wiring Orientation
Image
Published
10/11/2023 3:08 PM
AC Breaker On
Image
Published
10/11/2023 3:12 PM
AC Circuit Breaker On
Image
Published
10/11/2023 3:15 PM
Measure AC Line Filter Voltage
Image
Published
10/11/2023 3:17 PM
LD-260 Disconnect Switch Power On
Image
Published
05/04/2023 3:37 PM
DET-RPM-RAP-CM27

Replace an alternating current (AC) line filter. 

Equipment Hierarchy
Rapiscan VM-250 Vehicle Monitor
Rapiscan PM-700 Pedestrian Monitor
Rapiscan TM-850 Rail Monitor
Rapiscan CM-267 Conveyor Monitor
Frequency
Upon failure of AC line filter
Technician Level
Technician Level
Technician 2
x 1
Technician Level
Technician 1
x 1
Duration
Notes

Minutes

Length of time
30
Tools Required
Small Phillips (PH1) screwdriver
Small slotted (flathead) screwdriver
Digital multimeter DMM
Orange/yellow safety vest
Safety shoes
Safety glasses if required
Ladder; 2 meters, 6 feet tall; non-conducting if required
Orange traffic cones
Materials Required
AC line filter ( Rapiscan Part# 0418)
RPM Maintenance Guide Rev 2.0
Originators
David Alexander
Originating Organization
PNNL
Approver
Craig Stinson
Safety Concerns
Electrical
Final Documentation
Corrective Maintenance Report
Departmental Coordination

Prior to arrival, notify operators concerning expected work, duration, and anticipated alarms and fault indications. 

Date of Origin
Version
1.00
Version #
Revision Description

Updated pillar names

Revision Author
Preparation
Step 1

7268 - 7231 - Close lane; Remark:7233

Step 00

9632 - 9609 - Power off AC circuit breaker; Remark:9610

Step 00
Operation
Step 2

9635 - 9615 - Measure each black wire connection; Remark:9616

Step 00

9636 - 9617 - Measure each white wire connection; Remark:9618

Step 00
Operation
Step 3

9640 - 9624 - Mount new AC line filter; Remark:9625

Step 00

9641 - 9626 - Reconnect AC line filter wiring; Remark:9627

Step 00
Operation
Step 4
Document Type
Corrective Maintenance Procedure
Percent Complete
100.00
Percent Complete W/Media
100.00