Last Updated: 04/24/2025 1:45 AM
The following table lists all the components that make up the document.
Replace an alternating current (AC) line filter.
Minutes
Prior to arrival, notify operators concerning expected work, duration, and anticipated alarms and fault indications.
Updated pillar names
7621 - 1401 - Establish Initial Conditions; Remark:
1401 - Establish Initial Conditions
Establish Initial Conditions
7268 - 7231 - Close lane; Remark:7233
9053 - Warning : Traffic should temporarily be rerouted or halted during conduction of this pr...
Traffic should temporarily be rerouted or halted during conduction of this procedure to ensure maintenance provider safety and to prevent unscreened vehicles from passing.
7231 - Close lane
Close lane
7233 - Use orange safety (traffic control) cones to setup barriers. Practice establi...
Use orange safety (traffic control) cones to setup barriers. Practice established safety protocols.
7269 - 7232 - Open RPM door; Remark:7234
7232 - Open RPM door
Open RPM door
7234 - Open all doors needed to access components.
Open all doors needed to access components.
8221 - 7676 - Brief system operators on expected work, duration, anticipated alarms, and fa...; Remark:
7676 - Brief system operators on expected work, duration, anticipated alarms, and fa...
Brief system operators on expected work, duration, anticipated alarms, and fault indications before starting work
9632 - 9609 - Power off AC circuit breaker; Remark:9610
9607 - Warning : 110/240 VAC is present at circuit breaker and at the AC line filter.
110/240 VAC is present at circuit breaker and at the AC line filter.
9608 - Note : Normally, the OFF position will be when the circuit breaker ...
Normally, the OFF position will be when the circuit breaker switch is in the down position; however, confirm the correct position for the specific RPM.
9609 - Power off AC circuit breaker
Power off AC circuit breaker
9610 - The AC circuit breaker is located at the bottom of the control pillar. ...
The AC circuit breaker is located at the bottom of the control pillar.
There are two types of AC circuit breakers:
There should be no lit LEDs when the breaker is switched to OFF.
9633 - 9611 - Uninstall AC Line Filter; Remark:
9611 - Uninstall AC Line Filter
Uninstall AC Line Filter
9634 - 9612 - Confirm no AC voltage is present; Remark:9613
9612 - Confirm no AC voltage is present
Confirm no AC voltage is present
9613 - Using a digital multimeter, place the negative (-) lead on the mounting screw...
Using a digital multimeter, place the negative (-) lead on the mounting screw with the ground wire (green).

9635 - 9615 - Measure each black wire connection; Remark:9616
9614 - Warning : DO NOT proceed if voltage is present at either wire location...
DO NOT proceed if voltage is present at either wire location. Reconfirm the AC breaker is off as described in Step 1-4.
9615 - Measure each black wire connection
Measure each black wire connection
9616 - Using a digital multimeter, place the positive (+) lead on each of the mounti...
Using a digital multimeter, place the positive (+) lead on each of the mounting screws with the black wire.

9636 - 9617 - Measure each white wire connection; Remark:9618
9614 - Warning : DO NOT proceed if voltage is present at either wire location...
DO NOT proceed if voltage is present at either wire location. Reconfirm the AC breaker is off as described in Step 1-4.
9617 - Measure each white wire connection
Measure each white wire connection
9618 - Using a digital multimeter, place the positive (+) lead on each of the mounti...
Using a digital multimeter, place the positive (+) lead on each of the mounting screws with the white wire.

9637 - 9619 - Disconnect all wiring; Remark:9620
7352 - Note : It is good practice to verify all cables and connectors are labeled prior to ...
It is good practice to verify all cables and connectors are labeled prior to disconnection.
9619 - Disconnect all wiring
Disconnect all wiring
9620 - Using a small Phillips screwdriver, disconnect all the wires attached to the ...
Using a small Phillips screwdriver, disconnect all the wires attached to the AC line filter.
9638 - 9621 - Remove AC line filter; Remark:9622
9621 - Remove AC line filter
Remove AC line filter
9622 - Remove two M4 mounting screws and washers. Retain hardware.
Remove two M4 mounting screws and washers. Retain hardware.

3397 - 3395 - Label faulty component; Remark:3396
3395 - Label faulty component
Label faulty component
3396 - Use tag or tape. Include date of removal, description of failure symptoms, co...
Use tag or tape. Include date of removal, description of failure symptoms, country, site, and lane number. Dispose per Nuclear Smuggling Detection and Deterrence (NSDD) guidance or contractual requirements.
9639 - 9623 - Install New AC Line Filter; Remark:
9623 - Install New AC Line Filter
Install New AC Line Filter
9640 - 9624 - Mount new AC line filter; Remark:9625
7263 - Caution : Correct placement of connectors and wiring is critical to proper operation.
Correct placement of connectors and wiring is critical to proper operation.
9624 - Mount new AC line filter
Mount new AC line filter
9625 - Reuse retained M4 screws and internal washers. Remember to mount the ground w...
Reuse retained M4 screws and internal washers. Remember to mount the ground wire (green) under the M4 screw.

9641 - 9626 - Reconnect AC line filter wiring; Remark:9627
7263 - Caution : Correct placement of connectors and wiring is critical to proper operation.
Correct placement of connectors and wiring is critical to proper operation.
9626 - Reconnect AC line filter wiring
Reconnect AC line filter wiring
9627 - Make sure the load wire (+) is accross from the line wire (+).
Make sure the load wire (+) is accross from the line wire (+).
Black in line with black.
White in line with white.

7279 - 7249 - Return equipment to normal operating condition; Remark:
7249 - Return equipment to normal operating condition
Return equipment to normal operating condition
9642 - 9628 - Power on AC circuit breaker; Remark:9629
9607 - Warning : 110/240 VAC is present at circuit breaker and at the AC line filter.
110/240 VAC is present at circuit breaker and at the AC line filter.
9628 - Power on AC circuit breaker
Power on AC circuit breaker
9629 - AC Circuit Breaker On


9643 - 9630 - Verify AC line filter voltage; Remark:9631
9630 - Verify AC line filter voltage
Verify AC line filter voltage
9631 - Voltage should be present at both the input and output. 110-240 VAC will be p...
Voltage should be present at both the input and output. 110-240 VAC will be present depending on country of installation.

7280 - 7250 - Power on RPM; Remark:7251
7250 - Power on RPM
Power on RPM
7251 - Move LD-260 switch to ON position. The LED PWR ON
Move LD-260 switch to ON position. The LED PWR ON will illuminate.

7281 - 7252 - Verify RPM start-up; Remark:7253
7252 - Verify RPM start-up
Verify RPM start-up
7253 - RPM will perform a power on self-test (POST) and collect a background radiati...
RPM will perform a power on self-test (POST) and collect a background radiation measurement.
7282 - 7254 - Confirm network connection; Remark:7255
7254 - Confirm network connection
Confirm network connection
7255 - Contact operators to confirm communications have been reestablished between RPM ...
7283 - 7256 - Close and lock all RPM doors; Remark:
7256 - Close and lock all RPM doors
Close and lock all RPM doors
7842 - 7820 - Inform system operators upon completion of maintenance action; Remark:
7820 - Inform system operators upon completion of maintenance action
Inform system operators upon completion of maintenance action
322 - 321 - Document maintenance actions; Remark:
321 - Document maintenance actions
Document maintenance actions
2869 - 2585 - Document maintenance performed; Remark:2866
2585 - Document maintenance performed
Document maintenance performed
2866 - Record observations, times, and results for the maintenance report.
Record observations, times, and results for the maintenance report.
4706 - 4705 - Submit report; Remark:4864
4705 - Submit report
Submit report
4864 - As specified by management or contractual obligations.
As specified by management or contractual obligations.