Last Updated: 04/24/2025 1:46 AM
The following table lists all the components that make up the document.
Title | Type | Status | Last Updated |
---|---|---|---|
786 - 219 - Verify there are no sources of radiation near instrument; Remark:7 | Procedure Step
|
Published
|
04/20/2025 6:37 PM
|
219 - Verify there are no sources of radiation near instrument | Instruction
|
Published
|
04/12/2025 4:20 PM
|
7 - No Radiation symbol | Remark
|
Published
|
07/12/2021 1:34 PM
|
10474 - 220 - Power on instrument; Remark:10473 | Procedure Step
|
Published
|
04/20/2025 9:53 PM
|
220 - Power on instrument | Instruction
|
Published
|
04/06/2025 7:00 PM
|
10473 - | Remark
|
Published
|
12/01/2023 4:42 PM
|
679 - 612 - Wait for instrument to complete start-up sequence; Remark: | Procedure Step
|
Published
|
04/13/2025 6:33 PM
|
612 - Wait for instrument to complete start-up sequence | Instruction
|
Published
|
04/13/2025 6:38 PM
|
3085 - 3077 - SELECT mode; Remark:10470 | Procedure Step
|
Published
|
07/12/2021 1:41 PM
|
3077 - SELECT mode | Instruction
|
Published
|
07/12/2021 1:31 PM
|
10470 - | Remark
|
Published
|
12/01/2023 4:48 PM
|
10469 - 114 - PLACE instrument in SEARCH MODE; Remark:10468 | Procedure Step
|
Published
|
12/01/2023 4:49 PM
|
114 - PLACE instrument in SEARCH MODE | Instruction
|
Published
|
04/09/2020 1:39 AM
|
10468 - | Remark
|
Published
|
12/01/2023 4:55 PM
|
131 - 115 - SURVEY close to surface of item (5-10 centimeters); Remark:10467 | Procedure Step
|
Published
|
07/12/2021 1:42 PM
|
115 - SURVEY close to surface of item (5-10 centimeters) | Instruction
|
Published
|
06/13/2022 11:23 AM
|
10467 - | Remark
|
Published
|
12/01/2023 4:53 PM
|
10466 - 10465 - SURVEY SLOWLY over entire item (20 cm/s); Remark: | Procedure Step
|
Published
|
12/01/2023 4:56 PM
|
10465 - SURVEY SLOWLY over entire item (20 cm/s) | Instruction
|
Published
|
12/01/2023 4:56 PM
|
10464 - 10463 - CHANGE to FIND MODE when alarm is constant; Remark:10462 | Procedure Step
|
Published
|
12/01/2023 5:00 PM
|
10463 - CHANGE to FIND MODE when alarm is constant | Instruction
|
Published
|
12/01/2023 4:56 PM
|
10462 - | Remark
|
Published
|
12/01/2023 5:00 PM
|
3089 - 3080 - OBSERVE instrument response; Remark:10461 | Procedure Step
|
Published
|
07/12/2021 1:43 PM
|
3080 - OBSERVE instrument response | Instruction
|
Published
|
07/12/2021 1:27 PM
|
10461 - | Remark
|
Published
|
12/01/2023 5:04 PM
|
133 - 368 - Mark point(s) of interest; Remark:132 | Procedure Step
|
Published
|
04/20/2025 6:28 PM
|
368 - Mark point(s) of interest | Instruction
|
Published
|
06/11/2021 9:23 AM
|
132 - Marking location for further investigation | Remark
|
Published
|
11/09/2024 3:37 PM
|
136 - 117 - DOCUMENT results; Remark: | Procedure Step
|
Published
|
07/12/2021 1:44 PM
|
117 - DOCUMENT results | Instruction
|
Published
|
07/12/2021 1:26 PM
|
10347 - 313 - Power off instrument; Remark:10472 | Procedure Step
|
Published
|
04/21/2025 8:23 AM
|
313 - Power off instrument | Instruction
|
Published
|
07/23/2021 2:41 PM
|
10472 - | Remark
|
Published
|
12/01/2023 5:13 PM
|
10458 - Reminder : It is recommended to perform an operational test daily before use. DET-HHD-RA... | Annotation
|
Published
|
12/01/2023 5:14 PM
|
121 - Reminder : If instrument does not move for 60 seconds, it will switch to background mode... | Annotation
|
Published
|
07/12/2021 1:22 PM
|
10459 - Reminder : Do not operate the instrument at temperatures lower than 0°C or higher than ... | Annotation
|
Published
|
12/01/2023 5:15 PM
|
3076 - Reminder : Power off instrument prior to connecting to charger. | Annotation
|
Published
|
07/12/2021 1:20 PM
|
Pocket Guide | Document Type
|
Published
|
03/02/2020 3:32 PM
|
Reminder | Annotation Type
|
Published
|
04/08/2020 12:21 PM
|
No Radiation Symbol | Image
|
Published
|
08/13/2024 2:56 PM
|
Rapiscan PRM-470 CGN Power On_Off | Image
|
Published
|
12/01/2023 5:15 PM
|
Rapiscan PRM-470 CGN Select Mode | Image
|
Published
|
12/01/2023 5:15 PM
|
Rapiscan PRM-470 CGN Search Mode | Image
|
Published
|
12/01/2023 5:15 PM
|
Rapiscan PRM-470 CGN survey close to surface | Image
|
Published
|
12/01/2023 5:15 PM
|
Rapiscan PRM-470 CGN select mode | Image
|
Published
|
12/01/2023 5:15 PM
|
Rapiscan PRM-470 CGN Instrument response Find Mode | Image
|
Published
|
12/01/2023 5:15 PM
|
Mark_Source_Location_Trefoil | Image
|
Published
|
02/19/2023 10:54 AM
|
Rapiscan PRM-470 CGN Power On Off | Image
|
Published
|
12/01/2023 5:12 PM
|
DET-HHD-RAP-PG01
Search for radioactive materials
Technician Level
Duration
Preparation
Step 1
Main Step
786 - 219 - Verify there are no sources of radiation near instrument; Remark:7
Step 00
219 - Verify there are no sources of radiation near instrument
Verify there are no sources of radiation near instrument
7 - No Radiation symbol
Image

Step 2
Step 3
Main Step
679 - 612 - Wait for instrument to complete start-up sequence; Remark:
Step 00
612 - Wait for instrument to complete start-up sequence
Wait for instrument to complete start-up sequence
Step 4
Main Step
Step 6
Main Step
131 - 115 - SURVEY close to surface of item (5-10 centimeters); Remark:10467
Step 00
115 - SURVEY close to surface of item (5-10 centimeters)
SURVEY close to surface of item (5-10 centimeters)
10467 -
Image

Step 7
Main Step
10466 - 10465 - SURVEY SLOWLY over entire item (20 cm/s); Remark:
Step 00
10465 - SURVEY SLOWLY over entire item (20 cm/s)
SURVEY SLOWLY over entire item (20 cm/s)
Step 8
Main Step
10464 - 10463 - CHANGE to FIND MODE when alarm is constant; Remark:10462
Step 00
10463 - CHANGE to FIND MODE when alarm is constant
CHANGE to FIND MODE when alarm is constant
10462 -
Image

Step 9
Step 10
Main Step
133 - 368 - Mark point(s) of interest; Remark:132
Step 00
368 - Mark point(s) of interest
Mark point(s) of interest
Step 11
Main Step
136 - 117 - DOCUMENT results; Remark:
Step 00
117 - DOCUMENT results
DOCUMENT results
Step 12
Reminders
10458 - Reminder : It is recommended to perform an operational test daily before use. DET-HHD-RA...
Type
Reminder
It is recommended to perform an operational test daily before use. DET-HHD-RAP-RM01, PRM-470 Operational Test.
121 - Reminder : If instrument does not move for 60 seconds, it will switch to background mode...
Type
Reminder
If instrument does not move for 60 seconds, it will switch to background mode.
10459 - Reminder : Do not operate the instrument at temperatures lower than 0°C or higher than ...
Type
Reminder
Do not operate the instrument at temperatures lower than 0°C or higher than 38°C.
3076 - Reminder : Power off instrument prior to connecting to charger.
Type
Reminder
Power off instrument prior to connecting to charger.
Document Type
Pocket Guide
Percent Complete
100.00
Percent Complete W/Media