Last Updated: 04/25/2025 1:37 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Sensor Tech Radiation Pager
Device
Published
10/28/2024 3:52 PM
247 - 257 - Prepare instrument; Remark:
Procedure Step
Published
04/11/2025 9:08 PM
257 - Prepare instrument
Instruction
Published
04/11/2025 9:07 PM
786 - 219 - Verify there are no sources of radiation near instrument; Remark:7
Procedure Step
Published
04/20/2025 6:37 PM
219 - Verify there are no sources of radiation near instrument
Instruction
Published
04/12/2025 4:20 PM
7 - No Radiation symbol
Remark
Published
07/12/2021 1:34 PM
2980 - 220 - Power on instrument; Remark:2974
Procedure Step
Published
06/22/2021 9:21 AM
220 - Power on instrument
Instruction
Published
04/06/2025 7:00 PM
2974 - Choose a mode for operation.
Remark
Published
06/14/2021 3:40 PM
2976 - Vibrate only mode
Remark
Published
06/14/2021 3:41 PM
2977 - Audio only mode
Remark
Published
06/14/2021 3:42 PM
2910 - 319 - Perform operational test; Remark:2906
Procedure Step
Published
04/11/2022 9:56 AM
3058 - Note : It is recommended to perform an operational test daily before use
Annotation
Published
06/14/2021 5:28 PM
319 - Perform operational test
Instruction
Published
06/10/2021 8:31 PM
2906 - DET-HHD-STE-RPG-RM01, Radiation Pager Operational Test.
Remark
Published
08/02/2022 12:00 PM
2909 - 2903 - Operation; Remark:
Procedure Step
Published
06/22/2021 9:22 AM
2903 - Operation
Instruction
Published
06/15/2021 8:58 AM
2981 - 2904 - Wear instrument during shift; Remark:2978
Procedure Step
Published
06/22/2021 9:23 AM
2904 - Wear instrument during shift
Instruction
Published
06/15/2021 9:00 AM
2978 - Carry Radiation Pager in holster attached to belt. Instrument remains powered...
Remark
Published
06/14/2021 3:44 PM
3403 - 1096 - Respond to alarms; Remark:2979
Procedure Step
Published
06/06/2022 1:11 PM
1096 - Respond to alarms
Instruction
Published
06/15/2021 9:00 AM
2979 - Press acknowledge button to display alarm level.
Remark
Published
06/14/2021 3:45 PM
2908 - 2905 - Follow standard operating procedures; Remark:2907
Procedure Step
Published
06/22/2021 9:24 AM
2905 - Follow standard operating procedures
Instruction
Published
07/07/2021 9:04 AM
2907 - Maintain safe distance from nuclear or other radioactive material based on al...
Remark
Published
06/14/2021 3:46 PM
2942 - 313 - Power off instrument; Remark:2929
Procedure Step
Published
06/22/2021 10:19 AM
313 - Power off instrument
Instruction
Published
07/23/2021 2:41 PM
2929 - IO RadPager Power Off Button
Remark
Published
10/26/2024 10:45 AM
Operator Procedure
Document Type
Published
03/02/2020 3:31 PM
Note
Annotation Type
Published
03/02/2020 3:25 PM
No Radiation Symbol
Image
Published
08/13/2024 2:56 PM
Pager_Alarm_Mode_000575.png
Image
Published
03/27/2021 1:42 AM
Radiation Pager Power On
Image
Published
03/27/2021 1:42 AM
Carry Radiation Pager
Image
Published
03/27/2021 1:42 AM
Radiation Pager acknowledge alarm
Image
Published
03/27/2021 1:42 AM
power_off_000564.png
Image
Published
03/26/2021 1:40 AM
DET-HHD-STE-RPG-OP01

Use radiation pager to assess safety and indicate the presence of radiation.

Equipment Hierarchy
Sensor Tech Radiation Pager
Technician Level
Duration
Materials Required
DET-HHD-STE-RM01 Radiation Pager Operational Test
Originators
Tucker, Brian
Originating Organization
PNNL
Approver
Deena Bean
Date of Origin
Version
3.00
Version #
Revision #
2.00
Revision Description

Updated text for consistency with new FLO curriculum. Updated pictures. Optimized document for mobile viewing.

Revision Date
Document Type
Operator Procedure
Percent Complete
100.00
Percent Complete W/Media
100.00