Abbreviation
RM

RS-350 Operational Test

Last Updated: 05/17/2025 1:41 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Radiation Solutions Inc. RS-350
Device
Published
10/20/2024 8:53 AM
4819 - 257 - Prepare instrument; Remark:
Procedure Step
Published
07/27/2022 1:18 PM
1468 - Note : No artificial radioactive sources should be present during the initial startu...
Annotation
Published
07/27/2022 1:16 PM
257 - Prepare instrument
Instruction
Published
04/11/2025 9:07 PM
786 - 219 - Verify there are no sources of radiation near instrument; Remark:7
Procedure Step
Published
04/20/2025 6:37 PM
219 - Verify there are no sources of radiation near instrument
Instruction
Published
04/12/2025 4:20 PM
7 - No Radiation symbol
Remark
Published
07/12/2021 1:34 PM
4424 - 220 - Zapněte přístroj; Remark:4423
Procedure Step
Published
06/10/2022 6:25 AM
220 - Power on instrument
Instruction
Published
04/06/2025 7:00 PM
4423 - Open backpack and press power button for approximately 1 second.
Remark
Published
06/10/2022 5:14 AM
1496 - 1495 - Power on mobile device; Remark:
Procedure Step
Published
11/12/2020 4:40 PM
1495 - Power on mobile device
Instruction
Published
11/12/2020 4:20 PM
4425 - 4421 - Otevřete aplikaci RadMobile; Remark:4811
Procedure Step
Published
06/10/2022 5:16 AM
4422 - Note : Refer to DET-HHD-RSI-RS3-OP02, RS-350 RadMobile App Pairing for app ...
Annotation
Published
06/10/2022 5:16 AM
4421 - Open RadMobile app
Instruction
Published
06/10/2022 5:15 AM
4811 - IO RS350 RadMobile App Logo No Words
Remark
Published
07/07/2022 12:54 PM
4426 - 4420 - Zvolte název RS-350; Remark:4419
Procedure Step
Published
06/10/2022 5:17 AM
4420 - Select name of RS-350
Instruction
Published
06/10/2022 5:17 AM
4419 - The last connected device will appear as the first option on the screen. ...
Remark
Published
06/10/2022 5:17 AM
4427 - 1432 - Zkontrolujte připojení batohu k mobilnímu zařízení; Remark:4418
Procedure Step
Published
06/10/2022 5:20 AM
1432 - Verify backpack connection to mobile device
Instruction
Published
09/01/2020 7:34 PM
4418 - Gamma and neutron values will be changing.
Remark
Published
06/10/2022 5:20 AM
4428 - 2295 - Ověřte, zda jsou baterie dostatečně nabité; Remark:4416
Procedure Step
Published
06/10/2022 5:23 AM
2295 - Verify sufficient battery charge
Instruction
Published
04/06/2021 4:43 PM
4416 - Backpack battery life is indicated by the battery icon in the app.
Remark
Published
06/10/2022 5:22 AM
4417 - Mobile device battery life is typically indicated at the top of the display.
Remark
Published
06/10/2022 5:23 AM
252 - 232 - Check instrument gamma response; Remark:
Procedure Step
Published
07/29/2021 11:10 AM
232 - Check instrument gamma response
Instruction
Published
07/23/2021 9:58 AM
4497 - 235 - Place instrument next to radioactive gamma source; Remark:4817
Procedure Step
Published
06/10/2022 7:59 AM
235 - Place instrument next to radioactive gamma source
Instruction
Published
07/09/2021 1:39 PM
4817 - IO RS350 Move Closer to Rad Source Trefoil
Remark
Published
07/07/2022 7:25 PM
4498 - 1439 - Ověřte, že přístroj reaguje na radioaktivní zdroj; Remark:4495
Procedure Step
Published
06/10/2022 8:00 AM
1439 - Verify instrument responds to radioactive source
Instruction
Published
06/29/2022 11:50 PM
4495 - Gamma dose rate and count rate values will increase. Movin...
Remark
Published
07/07/2022 7:21 PM
4496 - Automatic identification of the radiation source may occur as the RS-350 is b...
Remark
Published
07/07/2022 7:23 PM
2251 - 2217 - Perform Identification Measurement; Remark:
Procedure Step
Published
07/28/2021 9:55 PM
2217 - Perform Identification Measurement
Instruction
Published
04/06/2021 5:13 PM
4452 - 859 - Start identification measurement; Remark:4430
Procedure Step
Published
06/10/2022 6:07 AM
859 - Start identification measurement
Instruction
Published
10/26/2020 7:00 PM
4430 - Tap menu icon.
Remark
Published
06/10/2022 5:38 AM
4451 - Tap Start dwell.
Remark
Published
06/10/2022 6:07 AM
4453 - 2220 - Wait for measurement to complete; Remark:4809
Procedure Step
Published
04/20/2025 12:56 PM
2220 - Wait for measurement to complete
Instruction
Published
10/22/2020 11:15 AM
4809 - IO RS350 Dwell Mode Timer Running 3/60
Remark
Published
07/06/2022 4:29 PM
4492 - 1442 - Zkontrolujte správnost výsledků identifikace; Remark:4491
Procedure Step
Published
06/10/2022 7:28 AM
1442 - Verify identification results are correct
Instruction
Published
09/02/2020 3:03 PM
4491 - Identification results should match the isotopes associated with the radioact...
Remark
Published
07/07/2022 7:19 PM
4493 - 4490 - Klepněte na tlačítko CLOSE (zavřít); Remark:4489
Procedure Step
Published
06/10/2022 7:29 AM
4490 - Tap CLOSE
Instruction
Published
06/10/2022 7:29 AM
4489 - This will return the instrument to Automatic mode.
Remark
Published
07/07/2022 7:18 PM
4494 - 4488 - Vzdalte přístroj od radioaktivního zdroje gama záření; Remark:4818
Procedure Step
Published
06/10/2022 7:30 AM
4488 - Move instrument away from radioactive gamma source
Instruction
Published
06/10/2022 7:30 AM
4818 - IO RS350 Move Away from Rad Source Trefoil
Remark
Published
07/07/2022 7:26 PM
4481 - 4480 - Check instrument neutron response (if available); Remark:
Procedure Step
Published
06/10/2022 7:19 AM
4480 - Check instrument neutron response (if available)
Instruction
Published
06/10/2022 7:19 AM
4485 - 3095 - Place instrument next to radioactive neutron source; Remark:4817
Procedure Step
Published
06/10/2022 7:31 AM
3095 - Place instrument next to radioactive neutron source
Instruction
Published
07/16/2021 10:49 AM
4486 - 1439 - Ověřte, že přístroj reaguje na radioaktivní zdroj; Remark:4484
Procedure Step
Published
06/10/2022 7:32 AM
4484 - Neutron count rate values will increase. The mobile device...
Remark
Published
07/07/2022 7:17 PM
4487 - 4483 - Vzdalte přístroj od zdroje radioaktivního neutronového záření; Remark:4818
Procedure Step
Published
06/10/2022 7:33 AM
4483 - Move instrument away from radioactive neutron source
Instruction
Published
06/10/2022 7:33 AM
253 - 242 - Document and report any unresolved problems; Remark:
Procedure Step
Published
06/22/2021 10:23 AM
242 - Document and report any unresolved problems
Instruction
Published
04/21/2025 11:45 AM
Routine Maintenance Procedure
Document Type
Published
03/02/2020 3:31 PM
minutes
Duration
Published
05/26/2022 11:41 AM
Annually
Frequency
Published
04/01/2020 11:37 AM
Before each use
Frequency
Published
08/31/2020 5:00 PM
Monthly
Frequency
Published
04/01/2020 11:36 AM
Note
Annotation Type
Published
03/02/2020 3:25 PM
Technician 1
Skill Level
Published
05/14/2020 2:56 PM
None
Tools
Published
05/06/2020 9:50 PM
No Radiation Symbol
Obrázek
Published
08/13/2024 2:56 PM
RS350 Power Button Green Light
Obrázek
Published
07/05/2022 3:50 PM
RS-350 RadMobile App Logo
Obrázek
Published
07/05/2022 4:34 PM
RS-350 App Connecting Serial Number Full Screen
Obrázek
Published
07/06/2022 1:18 PM
RS-350 Graph 70.5 nSv Boxes Dose, Counts, Graph
Obrázek
Published
07/05/2022 4:18 PM
RS-350 App Battery Icon Red Box
Obrázek
Published
07/06/2022 1:09 PM
RS-350 App Mobile Battery Percent
Obrázek
Published
07/06/2022 1:37 PM
RS-350 Move to Rad Source
Obrázek
Published
07/05/2022 3:56 PM
RS-350 Graph Alarm Response Red Arrow
Obrázek
Published
07/05/2022 4:22 PM
RS-350 Identification Dwell Result Co-60
Obrázek
Published
07/05/2022 5:35 PM
RS-350 App Menu Icon Red Box
Obrázek
Published
07/06/2022 1:27 PM
RS-350 Identification Dwell Start
Obrázek
Published
07/05/2022 5:37 PM
RS-350 Wait Dwell 3 of 60 sec
Obrázek
Published
07/05/2022 4:05 PM
RS-350 Close Dwell Mode
Obrázek
Published
07/05/2022 5:32 PM
RS-350 Move away from Rad Source
Obrázek
Published
07/05/2022 3:58 PM
RS-350 Alarm Neutron Red Box 10 CPS
Obrázek
Published
07/05/2022 5:20 PM

Handheld Radiation Monitor Routine Assessment

Last Updated: 05/17/2025 1:41 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Sensor Tech Handheld Radiation Monitor
Device
Published
10/28/2024 3:52 PM
4384 - 4383 - Document serial number; Remark:4382
Procedure Step
Published
06/06/2022 9:39 PM
4383 - Document serial number
Instruction
Published
06/06/2022 9:38 PM
4382 - Record information on the Handheld Radiation Monitor Assessment Form...
Remark
Published
06/06/2022 9:38 PM
4381 - 319 - Perform operational test; Remark:4380
Procedure Step
Published
06/06/2022 9:40 PM
319 - Perform operational test
Instruction
Published
06/10/2021 8:31 PM
4380 - DET-HHD-STE-HRM-RM01, Handheld Radiation Monitor Operational Test.
Remark
Published
06/06/2022 9:40 PM
4379 - 4378 - Replace battery; Remark:4377
Procedure Step
Published
06/06/2022 9:42 PM
4378 - Replace battery
Instruction
Published
06/06/2022 9:41 PM
4377 - DET-HHD-STE-HRM-RM02, Handheld Radiation Monitor Battery Replacement...
Remark
Published
06/06/2022 9:42 PM
4376 - 346 - Submit assessment form; Remark:4375
Procedure Step
Published
06/06/2022 9:43 PM
346 - Submit assessment form
Instruction
Published
06/16/2021 10:39 PM
4375 - Submit Handheld Radiation Monitor Assessment Form or HATS [Handheld ...
Remark
Published
06/06/2022 9:43 PM
Routine Maintenance Procedure
Document Type
Published
03/02/2020 3:31 PM
minutes
Duration
Published
05/26/2022 11:41 AM
Annually
Frequency
Published
04/01/2020 11:37 AM
Technician 1
Skill Level
Published
05/14/2020 2:56 PM
None
Tools
Published
05/06/2020 9:50 PM
HRM Serial Number Location
Obrázek
Published
08/02/2022 7:55 PM
HRM Assessment Form for RM03
File
Published
08/03/2022 10:47 AM