Last Updated: 06/28/2025 1:40 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Rapiscan PM-700 Pedestrian Monitor
Device
Not translated
06/05/2025 11:30 AM
Rapiscan VM-250 Vehicle Monitor
Device
Not translated
06/05/2025 11:26 AM
Rapiscan TM-850 Rail Monitor
Device
Not translated
06/05/2025 11:31 AM
Rapiscan CM-267 Conveyor Monitor
Device
Not translated
06/27/2024 1:02 PM
1401 - Establish Initial Conditions
Instruction
Not translated
09/30/2022 3:14 PM
7264 - 1401 - Establish Initial Conditions; Remark:
Procedure Step
Not translated
04/27/2023 7:00 PM
7592 - Inform system operators
Instruction
Not translated
06/29/2023 3:20 PM
11335 - Upon arrival, brief system operators on expected work, duration, anticipated ...
Remark
Not translated
04/20/2025 10:14 AM
7622 - 7592 - Inform system operators; Remark:11335
Procedure Step
Not translated
04/20/2025 10:15 AM
9053 - Warning : Traffic should temporarily be rerouted or halted during conduction of this pr...
Annotation
Not translated
09/27/2023 9:09 AM
7231 - Close lane
Instruction
Not translated
04/18/2023 1:00 PM
7233 - Use orange safety (traffic control) cones to setup barriers. Practice establi...
Remark
Not translated
04/24/2023 12:18 PM
7268 - 7231 - Close lane; Remark:7233
Procedure Step
Not translated
04/27/2023 7:01 PM
7232 - Open RPM door
Instruction
Not translated
04/18/2023 1:02 PM
7234 - Open all doors needed to access components.
Remark
Not translated
04/19/2025 7:48 PM
7269 - 7232 - Open RPM door; Remark:7234
Procedure Step
Not translated
04/27/2023 7:02 PM
7680 - Caution : Make sure to press release button on back of Ethernet cable before removing.
Annotation
Not translated
07/01/2023 11:54 PM
7679 - Disconnect Ethernet
Instruction
Not translated
05/16/2025 8:03 PM
11336 - Locate Ethernet connector on top of SC-770 controller. Press release button o...
Remark
Not translated
04/20/2025 11:21 AM
7755 - 7679 - Disconnect Ethernet; Remark:11336
Procedure Step
Not translated
04/20/2025 11:18 AM
7235 - Power off RPM
Instruction
Not translated
04/24/2023 12:30 PM
7236 - Move LD-260 switch to OFF position. The PWR ON
Remark
Not translated
04/27/2023 4:25 PM
7270 - 7235 - Power off RPM; Remark:7236
Procedure Step
Not translated
09/01/2023 7:57 PM
7290 - Disable tamper switches
Instruction
Not translated
05/01/2023 8:14 AM
7416 - Use a magnet to disable tamper switches for all open doors. Use adhesive tape...
Remark
Not translated
06/02/2023 1:18 PM
7454 - 7290 - Disable tamper switches; Remark:7416
Procedure Step
Not translated
06/02/2023 5:25 PM
5291-Nota : Se recomienda verificar que todos los cables y los conectores estén rotulados an...
Annotation
Published
10/24/2022 8:35 AM
7291 - Disable both infrared occupancy sensors
Instruction
Not translated
05/01/2023 8:15 AM
8514 - Verify sensors mounted in control pillar door are receivers.
Remark
Not translated
09/29/2023 11:52 AM
9205 - To disconnect sensor cable, turn collar counterclockwise and pull away from s...
Remark
Not translated
09/29/2023 11:52 AM
8561 - 7291 - Disable both infrared occupancy sensors; Remark:8514
Procedure Step
Not translated
09/18/2023 12:05 AM
8066 - Desenchufe el conector superior izquierdo
Instruction
Published
07/31/2023 1:49 PM
8065 - El conector de entrada de alimentación es un Molex de tres clavijas. Ambos LED d...
Remark
Published
07/31/2023 1:54 PM
8070 - 8066 - Desenchufe el conector superior izquierdo; Remark:8065
Procedure Step
Published
07/31/2023 1:54 PM
8076 - Reemplace el fusible
Instruction
Published
07/31/2023 4:31 PM
8077 - 8076 - Reemplace el fusible; Remark:
Procedure Step
Published
07/31/2023 4:31 PM
8074 - Quite la tuerca de retención del interruptor
Instruction
Published
07/31/2023 4:32 PM
8073 - Es posible que, para aflojar la tuerca de sujeción del interruptor, se necesite ...
Remark
Published
07/31/2023 4:38 PM
8075 - 8074 - Quite la tuerca de retención del interruptor; Remark:8073
Procedure Step
Published
07/31/2023 4:38 PM
8083 - Quite los cuatro tornillos de la placa de la cubierta
Instruction
Published
07/31/2023 7:44 PM
8082 -
Remark
Not translated
07/31/2023 7:46 PM
8084 - 8083 - Quite los cuatro tornillos de la placa de la cubierta; Remark:8082
Procedure Step
Published
07/31/2023 7:46 PM
8081 - Quite la placa de la cubierta
Instruction
Published
07/31/2023 7:51 PM
8080 -
Remark
Not translated
07/31/2023 7:52 PM
8085 - 8081 - Quite la placa de la cubierta; Remark:8080
Procedure Step
Published
07/31/2023 7:52 PM
8079 - Quite el fusible defectuoso
Instruction
Published
07/31/2023 7:53 PM
8078 - Tire o haga palanca para sacar con cuidado el fusible defectuoso del portafusibl...
Remark
Published
07/31/2023 7:54 PM
8086 - 8079 - Quite el fusible defectuoso; Remark:8078
Procedure Step
Published
07/31/2023 7:54 PM
3395 - Marque el componente defectuoso
Instruction
Published
08/07/2021 11:07 AM
3396 - Utilice una etiqueta o cinta adhesiva. Incluya la fecha de extracción, la descri...
Remark
Published
08/09/2021 11:35 AM
3397 - 3395 - Marque el componente defectuoso; Remark:3396
Procedure Step
Published
07/21/2024 6:59 AM
8096 - Instale un nuevo fusible
Instruction
Published
07/31/2023 7:55 PM
8097 - 8096 - Instale un nuevo fusible; Remark:
Procedure Step
Published
07/31/2023 7:56 PM
10322 - Place the new fuse in the fuse holder.
Instruction
Not translated
11/17/2023 7:18 PM
10323 - 10322 - Place the new fuse in the fuse holder.; Remark:
Procedure Step
Not translated
11/17/2023 7:19 PM
8094 - Instale la placa de la cubierta
Instruction
Published
07/31/2023 7:56 PM
8098 - 8094 - Instale la placa de la cubierta; Remark:
Procedure Step
Published
07/31/2023 7:56 PM
8093 - Instale los cuatro tornillos
Instruction
Published
07/31/2023 7:57 PM
8099 - 8093 - Instale los cuatro tornillos; Remark:
Procedure Step
Published
07/31/2023 7:57 PM
8092 - Instale la tuerca de retención del interruptor
Instruction
Published
07/31/2023 7:57 PM
8100 - 8092 - Instale la tuerca de retención del interruptor; Remark:
Procedure Step
Published
07/31/2023 7:58 PM
7249 - Return equipment to normal operating condition
Instruction
Not translated
04/08/2025 3:22 PM
7279 - 7249 - Return equipment to normal operating condition; Remark:
Procedure Step
Not translated
04/27/2023 4:13 PM
8088 - Enchufe de nuevo el conector superior izquierdo
Instruction
Published
07/31/2023 8:01 PM
8087 - Cuando el conector esté conectado de nuevo, el LED amarillo debería encenderse.
Remark
Published
07/31/2023 8:05 PM
8089 - 8088 - Enchufe de nuevo el conector superior izquierdo; Remark:8087
Procedure Step
Published
07/31/2023 8:06 PM
7250 - Power on RPM
Instruction
Not translated
05/01/2023 8:31 AM
7251 - Move LD-260 switch to ON position. The LED PWR ON
Remark
Not translated
05/10/2023 3:14 PM
7280 - 7250 - Power on RPM; Remark:7251
Procedure Step
Not translated
04/27/2023 4:14 PM
7252 - Verify RPM start-up
Instruction
Not translated
04/27/2023 2:23 PM
7253 - RPM will perform a power on self-test (POST) and collect a background radiati...
Remark
Not translated
05/10/2023 3:14 PM
7281 - 7252 - Verify RPM start-up; Remark:7253
Procedure Step
Not translated
04/20/2025 3:26 PM
5553-Precaución : La colocación correcta de los conectores y los cables es fundamental para el bue...
Annotation
Published
10/28/2022 2:19 PM
7305 - Enable both infrared occupancy sensors
Instruction
Not translated
05/01/2023 8:33 AM
8559 - To reconnect sensor cable, align connectors, push towards sensor, and turn co...
Remark
Not translated
09/29/2023 12:05 PM
8587 - 7305 - Enable both infrared occupancy sensors; Remark:8559
Procedure Step
Not translated
09/17/2023 11:03 PM
7310 - Enable tamper switches
Instruction
Not translated
05/01/2023 8:36 AM
7451 - Remove magnets and/or adhesive tape from door tamper switches.
Remark
Not translated
04/13/2025 5:46 PM
7474 - 7310 - Enable tamper switches; Remark:7451
Procedure Step
Not translated
06/02/2023 5:41 PM
7730 - Reconnect Ethernet
Instruction
Not translated
07/02/2023 2:34 AM
7731 - Insert Ethernet connector at top of SC-770 module. Connector will audibly "cl...
Remark
Not translated
07/02/2023 2:36 AM
7781 - 7730 - Reconnect Ethernet; Remark:7731
Procedure Step
Not translated
04/20/2025 11:00 AM
7254 - Confirm network connection
Instruction
Not translated
04/27/2023 2:22 PM
7255 - Contact operators to confirm communications have been reestablished between RPM ...
Remark
Not translated
05/10/2023 3:15 PM
7282 - 7254 - Confirm network connection; Remark:7255
Procedure Step
Not translated
04/27/2023 4:15 PM
319 - Haga una prueba de funcionamiento
Instruction
Published
06/10/2021 8:31 PM
9347 - DET-RPM-RAP-RM03 RPM Operational Test.
Remark
Not translated
10/03/2023 12:11 PM
9385 - 319 - Perform operational test; Remark:9347
Procedure Step
Not translated
06/16/2025 5:15 PM
7256 - Close and lock all RPM doors
Instruction
Not translated
04/27/2023 2:21 PM
7283 - 7256 - Close and lock all RPM doors; Remark:
Procedure Step
Not translated
09/01/2023 11:45 PM
8250 - Reopen Lane
Instruction
Not translated
09/07/2023 3:09 PM
8249 - Remove orange safety (traffic control) cones
Remark
Not translated
09/07/2023 3:09 PM
8260 - 8250 - Reopen Lane; Remark:8249
Procedure Step
Not translated
09/07/2023 3:09 PM
7820 - Inform system operators upon completion of maintenance action
Instruction
Not translated
07/07/2023 10:02 PM
7842 - 7820 - Inform system operators upon completion of maintenance action; Remark:
Procedure Step
Not translated
07/07/2023 11:15 PM
321 - Registre las tareas de mantenimiento
Instruction
Published
04/21/2025 11:19 AM
322 - 321 - Registre las tareas de mantenimiento; Remark:
Procedure Step
Published
06/17/2021 9:49 AM
2585 - Registre el mantenimiento realizado
Instruction
Published
07/09/2021 12:15 PM
2866 - Registre las observaciones, las horas y los resultados para el informe de manten...
Remark
Published
04/21/2025 11:39 AM
2869 - 2585 - Registre el mantenimiento realizado; Remark:2866
Procedure Step
Published
06/18/2021 5:58 PM
4705 - Envíe el informe
Instruction
Published
06/29/2022 9:50 AM
4864 - Según lo especificado por la gerencia o las obligaciones contractuales.
Remark
Published
07/28/2022 1:36 PM
4706 - 4705 - Envíe el informe; Remark:4864
Procedure Step
Published
06/29/2022 9:50 AM
Procedimiento de mantenimiento correctivo
Document Type
Published
03/02/2020 3:32 PM
20 minutos
Duration
Published
05/18/2020 5:44 PM
Cuando falle el fusible
Frequency
Published
11/17/2023 6:27 PM
Advertencia
Annotation Type
Published
03/02/2020 3:25 PM
Precaución
Annotation Type
Published
03/02/2020 3:24 PM
Nota
Annotation Type
Published
03/02/2020 3:25 PM
Técnico 2
Skill Level
Published
04/09/2020 1:17 AM
Claves de acceso al monitor de radiación de pórtico (RPM)
Replacement Parts
Published
04/27/2023 6:56 PM
Destornillador Phillips pequeño (PH1)
Tools
Published
05/14/2020 2:48 PM
Destornillador Phillips mediano (PH2)
Tools
Published
04/24/2020 4:40 PM
Chaleco de seguridad naranja/amarillo
Replacement Parts
Published
04/27/2023 6:56 PM
Calzado protector
Replacement Parts
Published
04/27/2023 6:56 PM
gafas de seguridad
Replacement Parts
Published
07/02/2023 4:48 PM
Escalera de 2 metros o 6 pies de alto; de material no conductor si es necesario
Replacement Parts
Published
07/02/2023 4:48 PM
Conos de tránsito naranjas
Replacement Parts
Published
04/27/2023 6:56 PM
llave inglesa pequeña
Tools
Published
07/31/2023 10:46 AM
Disconnect Ethernet cable on top of SC-770 box
Obrázek
Published
10/04/2023 2:59 PM
LD-260 Disconnect Switch Power Off
Obrázek
Published
04/24/2023 12:49 PM
Disable tamper switch
Obrázek
Published
09/07/2023 8:22 PM
Disable Tamper Switch
Obrázek
Published
06/02/2023 2:28 PM
Infrared Receiver
Obrázek
Published
09/17/2023 7:09 PM
Infrared Receiver DC
Obrázek
Published
09/29/2023 11:47 AM
Infrared Disconnect Sensor Cable
Obrázek
Published
09/17/2023 7:11 PM
Infrared Sensor Disconnect
Obrázek
Published
09/17/2023 7:12 PM
Unplugged LD-260
Obrázek
Published
11/17/2023 6:50 PM
LD-260 Switch Power Off
Obrázek
Published
11/17/2023 6:49 PM
LD-260 Nut
Obrázek
Published
11/17/2023 7:06 PM
Remove four cover plate screws
Obrázek
Published
07/31/2023 7:46 PM
LD-260 Cover Removed
Obrázek
Published
11/17/2023 8:25 PM
LD-260 Fuse
Obrázek
Published
11/17/2023 7:10 PM
LD-260
Obrázek
Published
07/31/2023 7:42 PM
LD-260 Disconnect Switch Power On
Obrázek
Published
06/04/2025 1:28 PM
Infrared Connection
Obrázek
Published
09/29/2023 12:02 PM
Infrared Cable Installation
Obrázek
Published
09/17/2023 10:12 PM
Infrared Sensor Cable
Obrázek
Published
09/17/2023 10:13 PM
Remove Magnet from Tamper.PNG
Obrázek
Published
09/28/2023 9:37 AM
Remove Magnet on Tamper Switch
Obrázek
Published
06/02/2023 4:31 PM
DET-RPM-RAP-CM05

Reemplace el fusible de la desconexión de carga LD-260

Equipment Hierarchy
Rapiscan PM-700 Pedestrian Monitor
Rapiscan VM-250 Vehicle Monitor
Rapiscan TM-850 Rail Monitor
Rapiscan CM-267 Conveyor Monitor
Frequency
Cuando falle el fusible
Technician Level
Technician Level
Técnico 2
x 1
Duration
Time increment
20 minutes
Length of time
20
Tools Required
Claves de acceso al monitor de radiación de pórtico (RPM)
Destornillador Phillips pequeño (PH1)
Destornillador Phillips mediano (PH2)
Chaleco de seguridad naranja/amarillo
Calzado protector
gafas de seguridad
Escalera de 2 metros o 6 pies de alto; de material no conductor si es necesario
Conos de tránsito naranjas
llave inglesa pequeña
Materials Required
Guía de mantenimiento del RPM Rev. 2.0
Fusible de acción rápida de 5 amperios de 5 x 20 mm
Originators
David Alexander
Originating Organization
PNNL
Approver
Craig Stinson
Final Documentation
Informe de mantenimiento correctivo
Departmental Coordination

Coordine el acceso con usuarios del sistema

Date of Origin
Version
0.00
Version #
Revision Description

Se actualizaron los nombres de pilares.

Revision Date
Revision Author
Step 1

7268 - 7231 - Close lane; Remark:7233

Step 00

7755 - 7679 - Disconnect Ethernet; Remark:11336

Step 00

8561 - 7291 - Disable both infrared occupancy sensors; Remark:8514

Step 00
Step 2

3397 - 3395 - Marque el componente defectuoso; Remark:3396

Step 00
Uso
Step 4

8587 - 7305 - Enable both infrared occupancy sensors; Remark:8559

Step 00
Step 5
Document Type
Corrective Maintenance Procedure
Percent Complete
47.50
Percent Complete W/Media
55.32