The following table lists all the components that make up the document.
Title | Type | Status | Last Updated |
---|---|---|---|
Sensor Tech TA600 Radiation Pager | Device
|
Published
|
10/28/2024 3:51 PM
|
247 - 257 - Prepare instrument; Remark: | Procedure Step
|
Published
|
04/11/2025 9:08 PM
|
257 - Prepare instrument | Instruction
|
Published
|
04/11/2025 9:07 PM
|
786 - 219 - Verify there are no sources of radiation near instrument; Remark:7 | Procedure Step
|
Published
|
04/20/2025 6:37 PM
|
219 - Verify there are no sources of radiation near instrument | Instruction
|
Published
|
04/12/2025 4:20 PM
|
7 - No Radiation symbol | Remark
|
Published
|
07/12/2021 1:34 PM
|
7555 - 220 - Zapněte přístroj; Remark:7542 | Procedure Step
|
Published
|
06/05/2023 5:57 PM
|
220 - Power on instrument | Instruction
|
Published
|
04/06/2025 7:00 PM
|
7542 - Set instrument to audio only mode. | Remark
|
Published
|
04/13/2025 5:48 PM
|
7556 - 612 - POČKEJTE, až přístroj dokončí spouštěcí sekvenci; Remark:7512 | Procedure Step
|
Published
|
04/13/2025 6:50 PM
|
612 - Wait for instrument to complete start-up sequence | Instruction
|
Published
|
04/13/2025 6:38 PM
|
7512 - Red numerical LED display will flash while collecting background for 30 secon... | Remark
|
Published
|
10/19/2023 7:54 AM
|
7557 - 7543 - Test Audible Alarm; Remark: | Procedure Step
|
Published
|
06/05/2023 5:59 PM
|
7543 - Test Audible Alarm | Instruction
|
Published
|
06/05/2023 3:31 PM
|
7558 - 7544 - Place instrument next to source of radiation; Remark:7545 | Procedure Step
|
Published
|
06/05/2023 5:59 PM
|
7544 - Place instrument next to source of radiation | Instruction
|
Published
|
06/05/2023 3:32 PM
|
7545 - TA600 Next to Source | Remark
|
Published
|
06/05/2023 3:34 PM
|
7559 - 2936 - Zkontrolujte, že zvukový alarm funguje správně; Remark:7547 | Procedure Step
|
Published
|
06/05/2023 6:00 PM
|
2936 - Verify audible alarm functions correctly | Instruction
|
Published
|
06/15/2021 4:09 PM
|
7547 - The instrument should respond as follows: Emit an audible b... | Remark
|
Published
|
06/05/2023 5:00 PM
|
7560 - 7548 - Potvrďte alarm; Remark:7549 | Procedure Step
|
Published
|
06/05/2023 6:01 PM
|
7548 - Acknowledge alarm | Instruction
|
Published
|
06/05/2023 5:03 PM
|
7549 - Press display button to stop alarm. Otherwise, the alarm will automatically s... | Remark
|
Published
|
06/05/2023 5:07 PM
|
7561 - 7550 - Vzdalte přístroj od zdroje záření; Remark:7551 | Procedure Step
|
Published
|
06/05/2023 6:02 PM
|
7550 - Move instrument away from source of radiation | Instruction
|
Published
|
06/05/2023 5:09 PM
|
7551 - Move source away from TA600 | Remark
|
Published
|
06/05/2023 5:12 PM
|
2914 - 2912 - Test vibration alarm; Remark: | Procedure Step
|
Published
|
06/06/2022 5:28 PM
|
2912 - Test vibration alarm | Instruction
|
Published
|
06/15/2021 4:11 PM
|
7562 - 7546 - Change to vibrate mode; Remark:7552 | Procedure Step
|
Published
|
06/05/2023 6:02 PM
|
7546 - Change to vibrate mode | Instruction
|
Published
|
06/05/2023 3:35 PM
|
7552 - Set instrument to vibrate only mode. | Remark
|
Published
|
06/05/2023 5:15 PM
|
7563 - 612 - POČKEJTE, až přístroj dokončí spouštěcí sekvenci; Remark:7512 | Procedure Step
|
Published
|
04/13/2025 6:55 PM
|
7553 - Note : If dial is turned to vibrate mode quickly, the instrument will not repeat sta... | Annotation
|
Published
|
06/05/2023 5:17 PM
|
7564 - 7544 - Umístěte přístroj vedle zdroje záření; Remark:7545 | Procedure Step
|
Published
|
06/05/2023 6:05 PM
|
7565 - 2938 - Zkontrolujte, že vibrační alarm funguje správně; Remark:7554 | Procedure Step
|
Published
|
06/05/2023 6:06 PM
|
2938 - Verify vibration alarm functions correctly | Instruction
|
Published
|
06/15/2021 4:12 PM
|
7554 - The instrument should respond as follows: Vibrate | Remark
|
Published
|
06/05/2023 5:24 PM
|
7566 - 7548 - Potvrďte alarm; Remark:7549 | Procedure Step
|
Published
|
06/05/2023 6:07 PM
|
7567 - 7550 - Vzdalte přístroj od zdroje záření; Remark:7551 | Procedure Step
|
Published
|
06/05/2023 6:08 PM
|
253 - 242 - Document and report any unresolved problems; Remark: | Procedure Step
|
Published
|
06/22/2021 10:23 AM
|
242 - Document and report any unresolved problems | Instruction
|
Published
|
04/21/2025 11:45 AM
|
Routine Maintenance Procedure | Document Type
|
Published
|
03/02/2020 3:31 PM
|
Daily | Frequency
|
Published
|
04/01/2020 11:36 AM
|
Before each use | Frequency
|
Published
|
08/31/2020 5:00 PM
|
Note | Annotation Type
|
Published
|
03/02/2020 3:25 PM
|
Technician 1 | Skill Level
|
Published
|
05/14/2020 2:56 PM
|
None | Tools
|
Published
|
05/06/2020 9:50 PM
|
No Radiation Symbol | Obrázek
|
Published
|
08/13/2024 2:56 PM
|
TA600 Audio Only | Obrázek
|
Published
|
06/04/2023 9:55 PM
|
TA600 Background | Obrázek
|
Published
|
06/04/2023 9:59 PM
|
TA600 Ready | Obrázek
|
Published
|
06/04/2023 9:59 PM
|
TA600 Next to Source | Obrázek
|
Published
|
03/29/2024 11:57 AM
|
TA600 Audible Alarm | Obrázek
|
Published
|
06/05/2023 5:00 PM
|
TA600 Acknowledge Alarm | Obrázek
|
Published
|
06/05/2023 5:07 PM
|
TA600 Away From Source | Obrázek
|
Published
|
06/05/2023 5:11 PM
|
TA600 Vibrate Only | Obrázek
|
Published
|
06/04/2023 9:56 PM
|
TA600 Vibration Alarm | Obrázek
|
Published
|
06/05/2023 5:23 PM
|
Check the Sensor Technology Engineering TA600 Radiation Pager operation and response to a source of radiation. The source of radiation may be any material that causes an alarm, including consumer products or naturally occuring radioactive materials.
Prior to arrival, notify operators concerning expected work and duration.
247 - 214 - Προετοιμασία οργάνου για λειτουργία; Remark:
257 - Prepare instrument
Prepare instrument
786 - 219 - Βεβαιωθείτε ότι δεν υπάρχουν πηγές ακτινοβολίας κοντά στο όργανο; Remark:7
219 - Βεβαιωθείτε ότι δεν υπάρχουν πηγές ακτινοβολίας κοντά στο όργανο
Βεβαιωθείτε ότι δεν υπάρχουν πηγές ακτινοβολίας κοντά στο όργανο
7 - No Radiation symbol

7555 - 220 - Zapněte přístroj; Remark:7542
220 - Power on instrument
Power on instrument
7542 - Set instrument to audio only mode.
Set instrument to audio only mode.

7556 - 612 - POČKEJTE, až přístroj dokončí spouštěcí sekvenci; Remark:7512
612 - Wait for instrument to complete start-up sequence
Wait for instrument to complete start-up sequence
7512 - Red numerical LED display will flash while collecting background for 30 secon...
Red numerical LED display will flash while collecting background for 30 seconds.
Instrument is ready when alarm threshold number is displayed.


7557 - 7543 - Test Audible Alarm; Remark:
7543 - Test Audible Alarm
Test Audible Alarm
7558 - 7544 - Place instrument next to source of radiation; Remark:7545
7544 - Place instrument next to source of radiation
Place instrument next to source of radiation
7545 - TA600 Next to Source

7559 - 2936 - Zkontrolujte, že zvukový alarm funguje správně; Remark:7547
2936 - Verify audible alarm functions correctly
Verify audible alarm functions correctly
7547 - The instrument should respond as follows: Emit an audible b...
The instrument should respond as follows:
- Emit an audible beep
- Yellow LED will flash

7560 - 7548 - Potvrďte alarm; Remark:7549
7548 - Acknowledge alarm
Acknowledge alarm
7549 - Press display button to stop alarm. Otherwise, the alarm will automatically s...
Press display button to stop alarm. Otherwise, the alarm will automatically silence after 14 seconds.

7561 - 7550 - Vzdalte přístroj od zdroje záření; Remark:7551
7550 - Move instrument away from source of radiation
Move instrument away from source of radiation
2914 - 2912 - Test vibration alarm; Remark:
2912 - Test vibration alarm
Test vibration alarm
7562 - 7546 - Change to vibrate mode; Remark:7552
7546 - Change to vibrate mode
Change to vibrate mode
7552 - Set instrument to vibrate only mode.
Set instrument to vibrate only mode.

7563 - 612 - POČKEJTE, až přístroj dokončí spouštěcí sekvenci; Remark:7512
7553 - Note : If dial is turned to vibrate mode quickly, the instrument will not repeat sta...
If dial is turned to vibrate mode quickly, the instrument will not repeat start-up sequence; instrument will be immediately ready for measurements.
612 - Wait for instrument to complete start-up sequence
Wait for instrument to complete start-up sequence
7512 - Red numerical LED display will flash while collecting background for 30 secon...
Red numerical LED display will flash while collecting background for 30 seconds.
Instrument is ready when alarm threshold number is displayed.


7564 - 7544 - Umístěte přístroj vedle zdroje záření; Remark:7545
7544 - Place instrument next to source of radiation
Place instrument next to source of radiation
7545 - TA600 Next to Source

7565 - 2938 - Zkontrolujte, že vibrační alarm funguje správně; Remark:7554
2938 - Verify vibration alarm functions correctly
Verify vibration alarm functions correctly
7554 - The instrument should respond as follows: Vibrate
The instrument should respond as follows:
- Vibrate
- Yellow LED will flash

7566 - 7548 - Potvrďte alarm; Remark:7549
7548 - Acknowledge alarm
Acknowledge alarm
7549 - Press display button to stop alarm. Otherwise, the alarm will automatically s...
Press display button to stop alarm. Otherwise, the alarm will automatically silence after 14 seconds.

7567 - 7550 - Vzdalte přístroj od zdroje záření; Remark:7551
7550 - Move instrument away from source of radiation
Move instrument away from source of radiation
253 - 242 - Document and report any unresolved problems; Remark:
242 - Document and report any unresolved problems
Document and report any unresolved problems