Last Updated: 05/06/2025 1:35 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Rapiscan PRM-470 CGN
Device
Published
10/28/2024 3:33 PM
247 - 257 - Prepare instrument; Remark:
Procedure Step
Published
04/11/2025 9:08 PM
257 - Prepare instrument
Instruction
Published
04/11/2025 9:07 PM
2548 - 205 - Disconnect charger; Remark:2547
Procedure Step
Published
08/02/2021 12:46 PM
205 - Disconnect charger
Instruction
Published
07/23/2021 2:42 PM
2547 - IO PRM-470 Remove Charger Cable
Remark
Published
11/02/2024 3:10 PM
397 - 313 - Power off instrument; Remark:398
Procedure Step
Published
06/11/2021 9:31 AM
313 - Power off instrument
Instruction
Published
07/23/2021 2:41 PM
398 - Press and hold the POWER button until instrument powers off....
Remark
Published
06/18/2021 6:02 PM
261 - 65 - Uvolněte čtyři (4) šrouby v krytu; Remark:264
Procedure Step
Published
08/12/2021 7:25 AM
65 - Loosen four (4) cover screws
Instruction
Published
07/22/2021 12:38 PM
264 - Use a medium Phillips (PH2) screwdriver. Screws do not need to be completely ...
Remark
Published
07/20/2021 3:59 PM
263 - 262 - Odstraňte kryt přístroje; Remark:413
Procedure Step
Published
08/11/2021 1:41 PM
2771 - Note : There are high-voltage detector circuit boards inside the instrument; however...
Annotation
Published
10/04/2022 11:06 AM
262 - Remove instrument cover
Instruction
Published
07/20/2021 3:35 PM
413 - PRM-470 Remove Instrument Cover
Remark
Published
11/01/2024 8:32 PM
2734 - 266 - Vyhledejte přípojku baterie; Remark:2733
Procedure Step
Published
08/18/2021 10:14 PM
3033 - Note : PRM-470 CGN models have an additional board and connectors not shown in remar...
Annotation
Published
10/04/2022 11:07 AM
266 - Locate battery connection
Instruction
Published
07/20/2021 3:36 PM
2733 - Battery connection is labeled 1.
Remark
Published
08/17/2021 3:23 PM
271 - 270 - Odpojte baterii; Remark:414
Procedure Step
Published
08/11/2021 1:42 PM
1345 - Note : It is good practice to ensure all cables and connectors are labeled prior to ...
Annotation
Published
10/04/2022 11:08 AM
270 - Disconnect battery
Instruction
Published
07/20/2021 3:37 PM
414 - PRM-470_Disconnect_battery
Remark
Published
11/02/2024 1:21 PM
2737 - 2736 - Odpojte kabely desky NHA-472; Remark:2735
Procedure Step
Published
08/18/2021 10:15 PM
2736 - Disconnect NHA-472 board wiring
Instruction
Published
08/17/2021 3:39 PM
2735 - Remove connectors at locations 5, 6, and 7.
Remark
Published
08/17/2021 3:24 PM
2739 - 2738 - Remove faulty NHA-472; Remark:
Procedure Step
Published
08/18/2021 10:15 PM
2738 - Remove faulty NHA-472
Instruction
Published
08/12/2021 10:10 AM
2742 - 2741 - Locate NHA-472 board; Remark:2740
Procedure Step
Published
08/18/2021 10:16 PM
2741 - Locate NHA-472 board
Instruction
Published
08/12/2021 10:25 AM
2740 - PRM-470CGN Neutron high voltage board
Remark
Published
11/02/2024 6:01 PM
2745 - 2744 - Odstraňte montážní matici NHA-472; Remark:2743
Procedure Step
Published
08/19/2021 3:12 PM
2744 - Remove NHA-472 mounting nut
Instruction
Published
08/12/2021 10:27 AM
2743 - Removing the NHA-472 mounting nut
Remark
Published
11/02/2024 6:02 PM
2748 - 2747 - Vyjměte desku NHA-472; Remark:2746
Procedure Step
Published
08/18/2021 10:16 PM
2747 - Remove NHA-472 board
Instruction
Published
08/12/2021 10:29 AM
2746 - Gently pry up each side and lift.
Remark
Published
08/17/2021 3:25 PM
2750 - 2749 - Install new NHA-472; Remark:
Procedure Step
Published
08/18/2021 10:17 PM
2749 - Install new NHA-472
Instruction
Published
08/12/2021 10:31 AM
2753 - 2752 - Mount new NHA-472; Remark:2751
Procedure Step
Published
08/18/2021 10:18 PM
2752 - Mount new NHA-472
Instruction
Published
08/12/2021 10:32 AM
2751 - Verify connectors are correctly aligned then press down.
Remark
Published
08/17/2021 3:26 PM
2756 - 2755 - Přišroubujte zpět montážní matici; Remark:2754
Procedure Step
Published
08/18/2021 10:18 PM
504 - Caution : Do not overtighten the mounting nut.
Annotation
Published
10/04/2022 11:11 AM
2755 - Reinstall mounting nut
Instruction
Published
08/12/2021 10:34 AM
2754 - Reinstall NHA-472 mounting nut
Remark
Published
11/02/2024 6:03 PM
2758 - 2757 - Reconnect wiring; Remark:
Procedure Step
Published
08/18/2021 10:18 PM
2757 - Reconnect wiring
Instruction
Published
08/12/2021 10:35 AM
2761 - 2760 - Reconnect all connectors except battery; Remark:2759
Procedure Step
Published
08/18/2021 10:19 PM
2760 - Reconnect all connectors except battery
Instruction
Published
08/12/2021 10:37 AM
2759 - Do not connect location 1.
Remark
Published
08/17/2021 3:27 PM
2763 - 305 - Opět zapojte baterii; Remark:2762
Procedure Step
Published
08/18/2021 10:19 PM
305 - Reconnect battery
Instruction
Published
07/29/2021 3:48 PM
2762 - Reconnect PRM-470 battery
Remark
Published
11/02/2024 6:05 PM
2766 - 2764 - Adjust neutron high voltage; Remark:
Procedure Step
Published
08/18/2021 10:19 PM
2765 - Note : The same circuit boards are used for both gamma and neutron detectors; howeve...
Annotation
Published
10/04/2022 11:13 AM
2764 - Adjust neutron high voltage
Instruction
Published
08/12/2021 10:38 AM
2770 - 2769 - Determine manufacturer of the neutron detector; Remark:2767
Procedure Step
Published
08/18/2021 10:20 PM
2769 - Determine manufacturer of the neutron detector
Instruction
Published
08/12/2021 10:39 AM
2767 - To access the neutron detector information, remove the moderator from the cas...
Remark
Published
08/17/2021 3:27 PM
2768 - Detector information is printed on the detector. There are two (2) common neu...
Remark
Published
06/18/2021 6:47 PM
2772 - 220 - Zapněte přístroj; Remark:228
Procedure Step
Published
08/18/2021 10:20 PM
220 - Power on instrument
Instruction
Published
04/06/2025 7:00 PM
228 - Press POWER button until the display turns on.
Remark
Published
06/18/2021 6:29 PM
2777 - 2776 - Připojte vysokonapěťovou sondu k DMM; Remark:2774
Procedure Step
Published
08/18/2021 10:21 PM
2776 - Connect HV probe to DMM
Instruction
Published
08/17/2021 3:40 PM
2774 - Use Fluke 80K-40 High Voltage Probe and Fluke 179 DMM. The GND tab should lin...
Remark
Published
08/17/2021 3:28 PM
2658 - 2566 - Přepněte DMM na stejnosměrné napětí; Remark:2613
Procedure Step
Published
08/18/2021 10:21 PM
2566 - Switch DMM to DC voltage
Instruction
Published
08/11/2021 3:41 PM
2613 - IO Fluke DMM Dial DC Volt
Remark
Published
11/02/2024 3:15 PM
2785 - 2567 - Najděte testovací bod uzemnění; Remark:2782
Procedure Step
Published
08/18/2021 10:21 PM
2567 - Locate ground test point
Instruction
Published
08/11/2021 3:42 PM
2782 - The neutron ground TP38 is located on the NHA-472 neutron board and might not...
Remark
Published
08/17/2021 3:29 PM
2790 - 2789 - Připojte vysokonapěťovou sondu k uzemnění; Remark:2787
Procedure Step
Published
08/19/2021 11:33 AM
2789 - Connect HV probe to ground
Instruction
Published
08/19/2021 11:28 AM
2787 - The ground connector for the HV probe may be directly connected to the ground...
Remark
Published
08/17/2021 3:30 PM
2788 - It may be easier to use a separate test lead (jumper wire) and connect the HV...
Remark
Published
08/17/2021 3:31 PM
2794 - 2792 - Najděte vysokonapěťový testovací bod; Remark:2791
Procedure Step
Published
08/18/2021 10:22 PM
2793 - Warning : The test point has high voltage. Only contact the test point with the high vo...
Annotation
Published
10/04/2022 11:20 AM
2792 - Locate high voltage test point
Instruction
Published
08/17/2021 3:41 PM
2791 - The neutron high voltage TP34 is located on the NHA-472 neutron board and mig...
Remark
Published
08/17/2021 3:32 PM
2797 - 2796 - Dotkněte se vysokonapěťovou sondou testovacího bodu; Remark:2795
Procedure Step
Published
08/19/2021 11:32 AM
2796 - Contact HV probe to test point
Instruction
Published
08/19/2021 11:30 AM
2795 - Contact TP34 (not labeled) with tip of red HV probe.
Remark
Published
08/17/2021 3:32 PM
2874 - 2873 - Najděte nastavení neutronového vysokého napětí; Remark:2872
Procedure Step
Published
08/18/2021 10:23 PM
2873 - Locate neutron high voltage adjustment
Instruction
Published
08/17/2021 3:42 PM
2872 - R10 on the NHA-472 neutron board is used to adjust the high voltage for the n...
Remark
Published
08/17/2021 3:33 PM
2885 - 2881 - Nastavte vysoké napětí pro neutrony; Remark:2875
Procedure Step
Published
08/18/2021 10:23 PM
2884 - Standard : High voltage for a GE Reuter-Stokes neutron detection is 990 Volts. High volt...
Annotation
Published
08/19/2021 11:25 AM
2881 - Adjust neutron high voltage
Instruction
Published
08/17/2021 3:43 PM
2875 - Use precision slotted (tweaker) screwdriver to adjust R10. The voltage should...
Remark
Published
08/17/2021 3:35 PM
2878 - The number indicated on the DMM must be multiplied by 1000 if the Fluke 80K-4...
Remark
Published
08/17/2021 3:35 PM
2889 - 2888 - Odstraňte kabely vysokonapěťové sondy; Remark:
Procedure Step
Published
08/19/2021 11:31 AM
2888 - Remove HV probe leads
Instruction
Published
08/19/2021 11:31 AM
2893 - 2892 - Vyhledejte nastavení zisku stupně 2 pro neutrony; Remark:2891
Procedure Step
Published
08/18/2021 10:24 PM
2892 - Locate neutron stage 2 gain adjustment
Instruction
Published
08/17/2021 4:05 PM
2891 - R17 on the NHA-472 neutron board is used to adjust the stage 2 gain.
Remark
Published
08/17/2021 3:36 PM
2896 - 2895 - Nastavte zisku stupně 2 na maximum; Remark:2894
Procedure Step
Published
08/18/2021 10:24 PM
2895 - Set stage 2 gain at maximum
Instruction
Published
08/17/2021 4:05 PM
2894 - Use precision slotted (tweaker) screwdriver to rotate R17 10 full turns clock...
Remark
Published
08/17/2021 3:37 PM
303 - 302 - Reassemble instrument; Remark:
Procedure Step
Published
10/07/2022 1:49 PM
302 - Reassemble instrument
Instruction
Published
06/16/2021 11:28 PM
2898 - 307 - Replace front cover; Remark:2897
Procedure Step
Published
08/18/2021 10:24 PM
304 - Caution : Ensure all wiring is inside the instrument while replacing cover.
Annotation
Published
10/04/2022 11:10 AM
307 - Replace front cover
Instruction
Published
07/20/2021 3:57 PM
2897 - Replace front cover - PRM470
Remark
Published
11/02/2024 6:06 PM
310 - 309 - Utáhněte čtyři (4) šrouby v krytu; Remark:417
Procedure Step
Published
08/11/2021 2:04 PM
569 - Caution : Do not overtighten screws.
Annotation
Published
06/16/2021 2:31 PM
309 - Tighten four (4) cover screws
Instruction
Published
07/22/2021 1:02 PM
417 - Use a medium Phillips (PH2) screwdriver.
Remark
Published
07/22/2021 1:18 PM
320 - 319 - Perform operational test; Remark:347
Procedure Step
Published
08/12/2021 7:12 AM
319 - Perform operational test
Instruction
Published
06/10/2021 8:31 PM
347 - Perform DET-HHD-RAP-RM01 PRM-470 Operational Test.
Remark
Published
07/21/2021 12:22 PM
322 - 321 - Document maintenance actions; Remark:
Procedure Step
Published
06/17/2021 9:49 AM
321 - Document maintenance actions
Instruction
Published
04/21/2025 11:19 AM
2869 - 2585 - Document maintenance performed; Remark:2866
Procedure Step
Published
06/18/2021 5:58 PM
2585 - Document maintenance performed
Instruction
Published
07/09/2021 12:15 PM
2866 - Record observations, times, and results for the maintenance report.
Remark
Published
04/21/2025 11:39 AM
4706 - 4705 - Submit report; Remark:4864
Procedure Step
Published
06/29/2022 9:50 AM
4705 - Submit report
Instruction
Published
06/29/2022 9:50 AM
4864 - As specified by management or contractual obligations.
Remark
Published
07/28/2022 1:36 PM
Corrective Maintenance Procedure
Document Type
Published
03/02/2020 3:32 PM
30 minutes
Duration
Published
04/01/2020 11:35 AM
As Needed
Frequency
Published
04/01/2020 11:36 AM
Note
Annotation Type
Published
03/02/2020 3:25 PM
Caution
Annotation Type
Published
03/02/2020 3:24 PM
Warning
Annotation Type
Published
03/02/2020 3:25 PM
Standard
Annotation Type
Published
03/02/2020 3:25 PM
Technician 2
Skill Level
Published
04/09/2020 1:17 AM
Medium Phillips (PH2) screwdriver
Tools
Published
04/24/2020 4:40 PM
5-mm nut (1/4 inch) nut driver or socket (optional)
Tools
Published
03/21/2021 5:00 PM
Needle nose pliers
Tools
Published
05/06/2020 4:10 PM
Precision slotted (tweaker) screwdriver
Tools
Published
03/20/2021 6:23 PM
Fluke 179 Digital Multimeter (DMM)
Tools
Published
03/20/2021 6:27 PM
Fluke 80K-40 high voltage (HV) probe
Tools
Published
03/20/2021 6:23 PM
Mini Hook Test Leads (optional)
Tools
Published
03/21/2021 5:02 PM
PRM-470 Disconnect Charger Cable
Obrázek
Published
03/16/2021 1:39 AM
PRM-470_Partial_Power_Button_Red_Highlight.png
Obrázek
Published
06/18/2021 6:28 PM
PRM470_Remove_Screws_Top_Case
Obrázek
Published
05/08/2020 6:05 PM
PRM-470_di_CGN_open_00536
Obrázek
Published
02/19/2023 11:26 AM
PRM-470 connectors shows 1-7
Obrázek
Published
02/19/2023 11:22 AM
PRM-470_Disconnect_battery
Obrázek
Published
05/09/2020 8:40 PM
PRM-470 connectors shows 5-7
Obrázek
Published
03/16/2021 1:39 AM
PRM-470 locate neutron CB
Obrázek
Published
03/16/2021 1:39 AM
PRM-470 NHA-470 CB mounting nut
Obrázek
Published
03/16/2021 1:39 AM
PRM-470 remove NHA-472 1 of 3
Obrázek
Published
03/16/2021 1:39 AM
PRM-470 Remove NHA-472 2 of 3
Obrázek
Published
03/16/2021 1:39 AM
PRM-470 Remove NHA-472 3 of 3
Obrázek
Published
03/16/2021 1:39 AM
PRM-470 align NHA-472 connectors 1 of 2
Obrázek
Published
03/16/2021 1:39 AM
PRM-470 press NHA-472 connectors 2 of 2
Obrázek
Published
03/16/2021 1:39 AM
PRM-470 mount NHA-472 nut
Obrázek
Published
03/16/2021 1:39 AM
PRM-470 connectors shows 2-7
Obrázek
Published
02/19/2023 11:35 AM
PRM-470 connector shows 1 for battery
Obrázek
Published
03/16/2021 1:39 AM
PRM-470_Reconnect_battery
Obrázek
Published
05/10/2020 8:16 PM
PRM-470 Neutron sleeve remove 1
Obrázek
Published
03/16/2021 1:39 AM
PRM-470_di_ntube2_000532.png
Obrázek
Published
03/16/2021 1:39 AM
PRM-470 Neutron locate manufacturer
Obrázek
Published
03/16/2021 1:39 AM
Fluke DMM HV Probe connector
Obrázek
Published
03/16/2021 1:39 AM
Fluke DMM on DC Voltage Dial
Obrázek
Published
03/16/2021 1:39 AM
PRM-470 locate TP38 ground 1 of 4
Obrázek
Published
03/16/2021 1:39 AM
PRM-470 locate TP38 ground 2 of 4
Obrázek
Published
03/16/2021 1:39 AM
PRM-470 locate TP38 ground 3 of 4
Obrázek
Published
03/16/2021 1:39 AM
PRM-470 locate TP38 ground 4 of 4
Obrázek
Published
03/16/2021 1:39 AM
PRM-470 locate TP34 high voltage
Obrázek
Published
03/16/2021 1:39 AM
PRM-470 TP34 high voltage measure
Obrázek
Published
02/19/2023 11:45 AM
PRM-470 adjust R10 location
Obrázek
Published
02/19/2023 11:32 AM
PRM-470 adjust R10 twist
Obrázek
Published
03/16/2021 1:39 AM
Fluke DMM Display in HV Probe Multiplier
Obrázek
Published
03/16/2021 1:39 AM
PRM-470 adjust R17 location
Obrázek
Published
02/19/2023 11:40 AM
PRM-470 adjust R17 twist
Obrázek
Published
03/16/2021 1:39 AM
PRM-470_di_close_000508.png
Obrázek
Published
06/18/2021 6:08 PM
PRM-470_Tighten_4_cover_screws
Obrázek
Published
05/10/2020 8:22 PM
DET-HHD-RAP-CM09

Replace NHA-472 (neutron high voltage board) on PRM-470 CGN.

Equipment Hierarchy
Rapiscan PRM-470 CGN
Frequency
As Needed
Technician Level
Technician Level
Technician 2
x 1
Duration
Time increment
30 minutes
Tools Required
Medium Phillips (PH2) screwdriver
5-mm nut (1/4 inch) nut driver or socket (optional)
Needle nose pliers
Precision slotted (tweaker) screwdriver
Fluke 179 Digital Multimeter (DMM)
Fluke 80K-40 high voltage (HV) probe
Mini Hook Test Leads (optional)
Materials Required
NHA-472 Board [Rapiscan Part #23111634 GHA Coated]
Originators
Tucker, Brian
Originating Organization
PNNL
Approver
Cody Hostick
Safety Concerns
Electrical
Retest Requirements
Final Documentation
Corrective Maintenance Report
Departmental Coordination

Prior to arrival, notify operators concerning expected work and duration.

Date of Origin
Version
0.00
Step 1
Step 5
Main Step

2770 - 2769 - Determine manufacturer of the neutron detector; Remark:2767

Step 00

2790 - 2789 - Připojte vysokonapěťovou sondu k uzemnění; Remark:2787

Step 00

2794 - 2792 - Najděte vysokonapěťový testovací bod; Remark:2791

Step 00

2885 - 2881 - Nastavte vysoké napětí pro neutrony; Remark:2875

Step 00
Step 7
Main Step
Document Type
Corrective Maintenance Procedure
Percent Complete
100.00
Percent Complete W/Media
100.00